Evaluation of the PrioCHECK T Trichinella AAD kit to detect Trichinella spiralis, T. britovi, and T. pseudospiralis larvae in pork using the automated digestion method Trichomatic-35

被引:5
作者
Basso, Walter [1 ]
Marreros, Nelson [2 ]
Hofmann, Larissa [1 ]
Salvisberg, Christine [1 ]
Lundstroem-Stadelmann, Britta [1 ]
Frey, Caroline F. [1 ]
机构
[1] Univ Bern, Vetsuisse Fac, Inst Parasitol, Dept Infect Dis & Pathobiol, Langgassstr 122, CH-3012 Bern, Switzerland
[2] Bern Univ Appl Sci, Sch Agr Forest & Food Sci HAFL, Langgasse 85, CH-3052 Zollikofen, Switzerland
关键词
Trichinellosis; Pig; Artificial digestion; Diagnostic; Pepsin; Serin-endopeptidase; MEAT;
D O I
10.1016/j.parint.2021.102449
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Trichinellosis is a potentially deadly parasitic zoonosis that is contracted by consuming undercooked infected meat. Reliable detection of infectious Trichinella spp. larvae in meat is therefore pivotal to ensure consumer's safety. The recently authorised PrioCHECK T Trichinella Alternative Artificial Digestion (AAD) test kit appears promising when used with the standard magnetic stirrer method, but evaluation with other apparatus types is lacking. In this study, the performance of the AAD kit in an adapted Trichomatic-35 (TM35) instrument was evaluated, first, at the Swiss National Reference Laboratory for trichinellosis (NRL); second, in a ring trial involving four Swiss official laboratories. Proficiency pork samples spiked with larvae of Trichinella spiralis, T. britovi, or T. pseudospiralis were tested with the AAD kit and with the reference pepsin-HCl digestion method in TM35 instruments. At the NRL, both methods yielded identical qualitative and similar quantitative results independently of the Trichinella species. In the ring trial, satisfactory results were obtained for 47/50 (94.0%) (AAD) and 62/67 (92.5%) (reference method) of the analysed samples. Technical problems impairing analysis were more frequently observed with the AAD kit (n = 22) than with the reference method (n = 5) and were mainly (16/22) reported by one of the external labs. When no technical issues were recorded, the performance of both methods was comparable, in agreement with the observations at the NRL; however, these results suggest a need for further training with the kit and standardisation of the adapted TM35 instruments.
引用
收藏
页数:8
相关论文
共 18 条
[1]  
[Anonymous], 2015, 13528 ISO
[2]   Fitting Linear Mixed-Effects Models Using lme4 [J].
Bates, Douglas ;
Maechler, Martin ;
Bolker, Benjamin M. ;
Walker, Steven C. .
JOURNAL OF STATISTICAL SOFTWARE, 2015, 67 (01) :1-48
[3]  
Commission E., 2015, Official J Eur Union, V58, P7
[4]  
Dopouy-Camet J., 2007, GUIDELINES SURVEILLA
[6]  
FARAWAY JJ, 2006, C&H TEXT STAT SCI, P1, DOI 10.1201/9781315382722
[7]   Test sensitivity of a commercial serine protease digestion kit for the detection of Trichinella spiralis and Trichinella pseudospiralis larvae in pig muscle [J].
Franssen, F. ;
Johne, A. ;
van der Giessen, J. ;
Noeckler, K. ;
Mayer-Scholl, A. .
FOOD MICROBIOLOGY, 2019, 78 :99-103
[8]   Assessment of the prevalence of Trichinella spp. in red foxes and Eurasian lynxes from Switzerland [J].
Frey, C. F. ;
Schuppers, M. E. ;
Mueller, N. ;
Ryser-Degiorgis, M. P. ;
Gottstein, B. .
VETERINARY PARASITOLOGY, 2009, 159 (3-4) :295-299
[9]  
FSVO (Federal Food Safety and Veterinary Office Switzerland), 2017, TECHN WEIS TRICH SCH
[10]  
Gajadhar Alvin, 2018, Food Waterborne Parasitol, V10, P6, DOI 10.1016/j.fawpar.2018.04.001