The feedback of heat rejection to air conditioning load during the nighttime in subtropical climate

被引:42
作者
Hsieh, Chun-Ming [1 ]
Aramaki, Toshiya [1 ]
Hanaki, Keisuke [1 ]
机构
[1] Univ Tokyo, Dept Urban Engn, Bunkyo Ku, Tokyo 1138656, Japan
关键词
nocturnal heat island; building energy; heat rejection; GIS; CFD; Taipei;
D O I
10.1016/j.enbuild.2006.06.016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Taipei City, located in the subtropical zone, has a basin landform. The summer is always hot and humid and the air temperature right after sunset is typically higher than 30 degrees C. Heat rejection from residential buildings in urban area, equipped with lots of the window type air conditioners, not only increases the air temperature outside, but also burdens the cooling load. Based on the time schedule of air conditioner use of Taipei citizens, the heat rejection/building energy use and the air temperature distribution were evaluated, and finally the additional electric consumption of air conditioners was predicted. Two software, EnergyPlus (building energy program) and Windperfect (CFD, computational fluid dynamics software) were employed in this study. In the CFD simulation, the geometry of buildings that covers 700 m in diameter was created with GIs (geographical information system) and the total mesh number was more than 3 millions. Three specified temperatures (T-am, T-bu and T-ac) were used to describe the temperature distribution within the urban canopy by hourly time variation and spatial distribution with height and horizontal profile. The results revealed that the temperature gradually increased with height and the temperature next to the buildings was always higher than the ambient air. The feedback (penalty) of heat rejection to cooling load was found 10.7% during 19:01 to 02:00 h on the following day. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1175 / 1182
页数:8
相关论文
共 14 条
  • [1] Energy effects of heat-island reduction strategies in Toronto, Canada
    Akbari, H
    Konopacki, S
    [J]. ENERGY, 2004, 29 (02) : 191 - 210
  • [2] Cool surfaces and shade trees to reduce energy use and improve air quality in urban areas
    Akbari, H
    Pomerantz, M
    Taha, H
    [J]. SOLAR ENERGY, 2001, 70 (03) : 295 - 310
  • [3] Flow and temperatures outside a high-rise residential building due to heat rejection by its air-conditioners
    Bojic, M
    Lee, M
    Yik, F
    [J]. ENERGY AND BUILDINGS, 2001, 33 (07) : 737 - 751
  • [4] *CONSTR MAG PULS H, 2003, TECHN COD CALC EX
  • [5] *DEP BUDG, 2002, ACC STAT TAIP CIT GO, V258
  • [6] Improvement of urban thermal environment by managing heat discharge sources and surface modification in Tokyo
    Dhakal, S
    Hanaki, K
    [J]. ENERGY AND BUILDINGS, 2002, 34 (01) : 13 - 23
  • [7] The effect of the Athens heat island on air conditioning load
    Hassid, S
    Santamouris, M
    Papanikolaou, N
    Linardi, A
    Klitsikas, N
    Georgakis, C
    Assimakopoulos, DN
    [J]. ENERGY AND BUILDINGS, 2000, 32 (02) : 131 - 141
  • [8] Impacts of city-block-scale countermeasures against urban heat-island phenomena upon a building's energy-consumption for air-conditioning
    Kikegawa, Y
    Genchi, Y
    Kondo, H
    Hanaki, K
    [J]. APPLIED ENERGY, 2006, 83 (06) : 649 - 668
  • [9] The effect of the London urban heat island on building summer cooling demand and night ventilation strategies
    Kolokotroni, M
    Giannitsaris, I
    Watkins, R
    [J]. SOLAR ENERGY, 2006, 80 (04) : 383 - 392
  • [10] LEE CP, 1999, STUDY URBAN HEAT ISL