Treatment of Vancouver B1 periprosthetic femoral fractures using Intrauma Iron Lady® locking plate: A retrospective study on 32 patients

被引:1
|
作者
Del Chiaro, A. [1 ]
Piolanti, N. [1 ]
Bonicoli, E. [1 ]
Parchi, P. D. [1 ]
Marchetti, S. [1 ]
Scaglione, M. [1 ]
机构
[1] Univ Pisa, Via Paradisa 2, Pisa, Italy
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2021年 / 52卷 / 08期
关键词
Periprosthetic Femoral Fracture; PFF; Vancouver B1; Locking plate; Internal Fixation; TOTAL HIP-ARTHROPLASTY; IPSILATERAL FEMUR; FIXATION; CLASSIFICATION; CONJUNCTION; CERCLAGE; STRUT;
D O I
10.1016/j.injury.2021.02.089
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Periprosthetic femoral fractures (PFF) actually represent a serious public health problem. They are reported to occur in 0,1-4.5% of all patients undergoing total hip replacement (THR). PFF are commonly distinguished using the Vancouver classification. This study principal aim is to evaluate results obtained using the Intrauma Iron Lady (R) Conical Coupling locking plate for the treatment of Vancouver type B1 periprosthetic femoral fractures. Materials and Methods: We enrolled 32 patients affected by Vancouver B1 PFF and treated with the same device. Metal cerclages were additionally used in 12 (38%) patients. A clinical and radiographical post-operative follow-up was then planned at 1, 3 and 6 months after surgery; than the follow-up was annually fixed. Results: Mean age at the moment of trauma was 76,7 years. All involved femoral stem were uncemented and the they were all radiographically and intraoperativelly judged to be stable. Mean post-operative follow-up period was 5,8 years. 29 patients (91%) presented healed fracture at 6 months follow-up. 9% patients developed a superficial surgical site infection. Discussion and Conclusions: Literature highlights that Vancouver B1 PFF should be treated with open reduction and internal fixation (ORIF) using polyaxial locking plates. However, no single technique has gained universal acceptance to be superior that the other. The current reported healing rate ranges from 40 to 100%. Using the Intrauma Iron Lady (R) Conical Coupling locking plate, we obtained a healing rate of 91%; this data is consistent with recent literature. Moreover, the role of cerclages in addition to femoral plating is actually controversial because they potentially damage the soft callus vascularization. Our results showed no difference in term of healing rate between patients with and without cerclages, according with some of most recent articles. A prospective study with a higher number of patients should be carried out in order to better evaluate the role of cerclages on healing rate but also the complications frequency after PFF surgical treatment. (c) 2021 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )
引用
收藏
页码:2459 / 2462
页数:4
相关论文
共 50 条
  • [41] Plain films are not accurate in planning internal fixation in vancouver type B1 periprosthetic femoral fractures and in distinguishing between subtypes B1 And B2
    Cinotti, Gianluca
    Sinno, Ennio
    Fornara, Gianluca
    LaTorre, Giuseppe
    Giannicola, Giuseppe
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (06): : 1592 - 1596
  • [42] BCIFS in the treatment of Vancouver type B1 periprosthetic femoral fracture combined with comminuted femoral stem fracture: A case report
    Yin, Lu
    Liu, Yang
    Zeng, Shengqiang
    Shen, Huarui
    ASIAN JOURNAL OF SURGERY, 2024, 47 (05) : 2274 - 2276
  • [43] Treatment of type B periprosthetic femur fractures with curved non-locking plate with eccentric holes: Retrospective study of 43 patients with minimum 1-year follow-up
    Lunebourg, A.
    Mouhsine, E.
    Cherix, S.
    Ollivier, M.
    Chevalley, F.
    Wettstein, M.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (03) : 277 - 282
  • [44] Locking compression plate fixation of femoral intertrochanteric fractures in patients with preexisting proximal femoral deformity: a retrospective study
    Fan, Shan
    Yin, Mingming
    Xu, Yibo
    Ren, Cheng
    Ma, Teng
    Lu, Yao
    Li, Ming
    Li, Zhong
    Zhang, Kun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [45] Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs
    Lochab, Jasjit
    Carrothers, Andrew
    Wong, Edwin
    McLachlin, Stewart
    Aldebeyan, Wassim
    Jenkinson, Richard
    Whyne, Cari
    Nousiainen, Markku T.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (01) : 15 - 20
  • [46] Management of Vancouver B2 and B3 Periprosthetic Proximal Femoral Fractures by Distal Locking Femoral Stem (Cannulok) in Patients 75 Years and Older
    El-Bakoury, Ahmed
    Hosny, Hazem
    Williams, Mark
    Keenan, Jonathan
    Yarlagadda, Rathan
    JOURNAL OF ARTHROPLASTY, 2017, 32 (02) : 541 - 545
  • [47] Outcome after operative treatment of Vancouver type B1 and C periprosthetic femoral fractures: open reduction and internal fixation versus revision arthroplasty
    Helmut L. Laurer
    Sebastian Wutzler
    Susann Possner
    Emanuel V. Geiger
    André El Saman
    Ingo Marzi
    Johannes Frank
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 983 - 989
  • [48] Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study
    Lewis, Gregory S.
    Caroom, Cyrus T.
    Wee, Hwabok
    Jurgensmeier, Darin
    Rothermel, Shane D.
    Bramer, Michelle A.
    Reid, John Spence
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (10) : e364 - e370
  • [49] Analysis of risk factors for revision in distal femoral fractures treated with lateral locking plate: a retrospective study in Chinese patients
    Hou, Guojin
    Zhou, Fang
    Tian, Yun
    Ji, Hongquan
    Zhang, Zhishan
    Guo, Yan
    Lv, Yang
    Yang, Zhongwei
    Zhang, Yawen
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [50] Osteosynthesis of periprosthetic type A and B femoral fractures using an unlocked plate with integrated cerclage cable and trochanteric hook: A multicenter retrospective study of 45 patients with mean follow-up of 20 months
    Gavanier, B.
    Houfani, F.
    Dumoulin, Q.
    Bernard, E.
    Mangin, M.
    Mainard, D.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (12): : 2827 - 2832