Graphene Quantums Dots Combined with Endonuclease Cleavage and Bidentate Chelation for Highly Sensitive Electrochemiluminescent DNA Biosensing

被引:60
作者
Lou, Jing
Liu, Shanshan
Tu, Wenwen [1 ]
Dai, Zhihui
机构
[1] Nanjing Normal Univ, Jiangsu Collaborat Innovat Ctr Biomed Funct Mat, Coll Chem & Mat Sci, Nanjing 210023, Jiangsu, Peoples R China
基金
中国国家自然科学基金; 高等学校博士学科点专项科研基金;
关键词
RESONANCE ENERGY-TRANSFER; SIGNAL AMPLIFICATION; ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLES; ELECTROGENERATED CHEMILUMINESCENCE; MULTIPLEXED DETECTION; NUCLEIC-ACID; PROTEIN; OXIDE; IMMOBILIZATION;
D O I
10.1021/ac5037318
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel strategy for highly sensitive electrochemiluminescence (ECL) detection of DNA was proposed based on site-specific cleavage of BamHI endonuclease combined with the excellent ECL activity of graphene quantum dots (GQDs) and bidentate chelation of the dithiocarbamate DNA (DTC-DNA) probe assembly. The difference between photoluminescence and ECL spectral peaks suggested that a negligible defect existed on the GQDs surface for generation of an ECL signal. The formed DTC-DNA was directly attached to the gold surface by bidentate anchoring (S-Au-S bonds), which conferred a strong affinity between the ligands and the gold surface, increasing the robustness of DNA immobilization on the gold surface. BamHI endonuclease site-specifically recognized and cleaved the duplex symmetrical sequence, which made the double-stranded DNA fragments and GQDs break off from the electrode surface, inducing a decrease of the ECL signal. Using hepatitis C virus-1b genotype complementary DNA (HCV-1b cDNA) as a model, a novel signal-off ECL DNA biosensor was developed based on variation of the ECL intensity before and after digestion of the DNA hybrid. Electrochemical impedance spectroscopy confirmed the successful fabrication of the ECL DNA biosensor. This ECL biosensor for HCV-1b cDNA determination exhibited a linear range from 5 fM to 100 pM with a detection limit of 0.45 fM at a signal-to-noise ratio of 3 and showed satisfactory selectivity and good stability, which validated the feasibility of the designed strategy. The proposed strategy may be conveniently combined with other specific biological recognition events for expansion of the biosensing application, especially in clinical diagnoses.
引用
收藏
页码:1145 / 1151
页数:7
相关论文
共 46 条
  • [31] Immobilization strategies to develop enzymatic biosensors
    Sassolas, Audrey
    Blum, Loic J.
    Leca-Bouvier, Beatrice D.
    [J]. BIOTECHNOLOGY ADVANCES, 2012, 30 (03) : 489 - 511
  • [32] Air stability of alkanethiol self-assembled monolayers on silver and gold surfaces
    Schoenfisch, MH
    Pemberton, JE
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (18) : 4502 - 4513
  • [33] Distance-dependent quenching and enhancing of electrochemiluminescence from a CdS: Mn nanocrystal film by Au nanoparticles for highly sensitive detection of DNA
    Shan, Yun
    Xu, Jing-Juan
    Chen, Hong-Yuan
    [J]. CHEMICAL COMMUNICATIONS, 2009, (08) : 905 - 907
  • [34] A facile in situ generation of dithiocarbamate ligands for stable gold nanoparticle - oligonucleotide conjugates
    Sharma, Jaswinder
    Chhabra, Rahul
    Yan, Hao
    Liu, Yan
    [J]. CHEMICAL COMMUNICATIONS, 2008, (18) : 2140 - 2142
  • [35] Signal-on electrochemical Y or junction probe detection of nucleic acid
    Shen, Zuliang
    Nakayama, Shizuka
    Semancik, Steve
    Sintim, Herman O.
    [J]. CHEMICAL COMMUNICATIONS, 2012, 48 (61) : 7580 - 7582
  • [36] Electrochemical detection of hepatitis C virus with signal amplification using BamHI endonuclease and horseradish peroxidase-encapsulated nanogold hollow spheres
    Tang, Dianping
    Tang, Juan
    Su, Biling
    Li, Qunfang
    Chen, Guonan
    [J]. CHEMICAL COMMUNICATIONS, 2011, 47 (33) : 9477 - 9479
  • [37] Using Graphene Quantum Dots as Photoluminescent Probes for Protein Kinase Sensing
    Wang, Ying
    Zhang, Li
    Liang, Ru-Ping
    Bai, Jian-Mei
    Qiu, Jian-Ding
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (19) : 9148 - 9155
  • [38] Reduced Graphene Oxide Upconversion Nanoparticle Hybrid for Electrochemiluminescent Sensing of a Prognostic Indicator in Early-Stage Cancer
    Wu, Li
    Wang, Jiasi
    Yin, Meili
    Ren, Jinsong
    Miyoshi, Daisuke
    Sugimoto, Naoki
    Qu, Xiaogang
    [J]. SMALL, 2014, 10 (02) : 330 - 336
  • [39] Highly sensitive electrochemiluminescent cytosensing using carbon nanodot@Ag hybrid material and graphene for dual signal amplification
    Wu, Li
    Wang, Jiasi
    Ren, Jinsong
    Li, Wen
    Qu, Xiaogang
    [J]. CHEMICAL COMMUNICATIONS, 2013, 49 (50) : 5675 - 5677
  • [40] Sensitive Electrochemiluminescence Biosensor Based on Au-ITO Hybrid Bipolar Electrode Amplification System for Cell Surface Protein Detection
    Wu, Mei-Sheng
    Yuan, Da-Jing
    Xu, Jing-Juan
    Chen, Hong-Yuan
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (24) : 11960 - 11965