Field edge smoothing for multileaf collimators

被引:27
作者
Galvin, JM
Leavitt, DD
Smith, AA
机构
[1] NYU,MED CTR,DEPT RADIOL,NEW YORK,NY 10016
[2] UNIV UTAH,SCH MED,DEPT RADIOL,SALT LAKE CITY,UT 84132
[3] HARVARD UNIV,MASSACHUSETTS GEN HOSP,SCH MED,DEPT RADIAT MED,BOSTON,MA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1996年 / 35卷 / 01期
关键词
multileaf; penumbra;
D O I
10.1016/S0360-3016(96)85015-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To smooth the scalloped dose pattern that occurs for stepped leaves at a treatment field edge defined by a multileaf collimator. Methods and Materials: Fields with centers shifted slightly in space were superimposed to blur the staggered dose distribution at the field edge, Film dosimetry was used to monitor changes, The dose distribution for a single field position was compared to the distribution for one and three shifts, Three depths were examined and divergent alloy blocks were included in the comparison, Results: The structure that appears at an edge for a single field when leaves are staggered was nearly eliminated when the field was shifted three times to give a total of four different positions, However, shifting the held one time so that two fields were superimposed gave an intermediate result with only slight improvement in the undulating dose distribution, For the four superimposed fields, the 50% isodose pattern converged to a smoothed line running along the center of the original undulating pattern, The 80 and 20% isodoses did not converge to the center of their scalloped patterns, Instead, these isodose lines were spread leaving a larger penumbra width than a divergent alloy block, Conclusions: Shifting and adding fields is an effective method for smoothing the staggered dose distribution that results when the leaves of a multileaf collimator are stepped to form an irregular field pattern. However, the width of the penumbra for the combined fields is wider than the penumbra for a cerrobend block.
引用
收藏
页码:89 / 94
页数:6
相关论文
共 8 条
  • [1] BURMAN C, 1994, MED PHYS, V21, P885
  • [2] EVALUATION OF MULTILEAF COLLIMATOR DESIGN FOR A PHOTON-BEAM
    GALVIN, JM
    SMITH, AR
    MOELLER, RD
    GOODMAN, RL
    POWLIS, WD
    RUBENSTEIN, J
    SOLIN, LJ
    MICHAEL, B
    NEEDHAM, M
    HUNTZINGER, CJ
    KLIGERMAN, MM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (04): : 789 - 801
  • [3] CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM
    GALVIN, JM
    SMITH, AR
    LALLY, B
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02): : 181 - 192
  • [4] COMBINING MULTILEAF FIELDS TO MODULATE FLUENCE DISTRIBUTIONS
    GALVIN, JM
    CHEN, XG
    SMITH, RM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (03): : 697 - 705
  • [5] GALVIN JM, 1992, INT J RADIAT ONCOL, V25, P571
  • [6] LEAVITT DD, 1991, P VAR AUSTR US M SYD
  • [7] INITIATION OF MULTILEAF COLLIMATOR CONFORMAL RADIATION-THERAPY
    POWLIS, WD
    SMITH, AR
    CHENG, E
    GALVIN, JM
    VILLARI, F
    BLOCH, P
    KLIGERMAN, MM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (02): : 171 - 179
  • [8] SMITH AR, 1988, P 12 VAR US M PEBBL