Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion

被引:481
作者
Hallab, NJ
Bundy, KJ
O'Connor, K
Moses, RL
Jacobs, JJ
机构
[1] Rush Presbyterian St Lukes Med Ctr, Dept Orthoped Surg, Chicago, IL 60612 USA
[2] Tulane Univ, Dept Biomed Engn, New Orleans, LA 70118 USA
[3] Tulane Univ, Dept Chem Engn, New Orleans, LA 70118 USA
[4] Louisiana State Univ, Sch Med, Dept Anat, New Orleans, LA USA
来源
TISSUE ENGINEERING | 2001年 / 7卷 / 01期
关键词
D O I
10.1089/107632700300003297
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Directed cell adhesion remains an important goal of implant and tissue engineering technology. In this study, surface energy and surface roughness were investigated to ascertain which of these properties show more overall influence on biomaterial-cell adhesion and colonization. Jet impingement was used to quantify cellular adhesion strength. Cellular proliferation and extracellular matrix secretion were used to characterize colonization of 3T3MC fibroblasts on: HS25 (a cobalt based implant alloy, ASTM F75), 316L stainless steel, Ti-6Al-4V (a titanium implant alloy), commercially pure tantalum (Ta), polytetrafluoroethylene (PTFE), silicone rubber (SR), and high-density polyethylene (HDPE). The metals exhibited a nearly five-fold greater adhesion strength than the polymeric materials tested. Generally, surface energy was proportional to cellular adhesion strength. Only polymeric materials demonstrated significant increased adhesion strength associated with increased surface roughness. Cellular adhesion on metals demonstrated a linear correlation with surface energy. Less than half as much cellular proliferation was detected on polymeric materials compared to the metals. However the polymers tested demonstrated greater than twice the amount of secreted extracellular matrix (ECM) proteins on a per tell basis than the metallic materials. Thus, surface energy may be a more important determinant of cell adhesion and proliferation, and may be more useful than surface roughness for directing cell adhesion and cell colonization onto engineered tissue scaffoldings.
引用
收藏
页码:55 / 71
页数:17
相关论文
共 22 条
  • [1] Andrade J. D., 1985, The contact angle and interface energetics
  • [2] [Anonymous], 1988, BIOFOULING
  • [3] ADSORPTION OF PLASMA-PROTEINS ON HYDROPHOBIC SURFACES .3. SERUM, PLASMA, AND BLOOD
    BAGNALL, RD
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1978, 12 (05): : 707 - 721
  • [4] BAGNALL RD, 1980, J BIOMED MATER RES, V18, P1
  • [5] IDENTIFICATION OF PROTEINS ABSORBED FROM HUMAN-PLASMA TO GLASS BEAD COLUMNS - PLASMIN-INDUCED DEGRADATION OF ADSORBED FIBRINOGEN
    BRASH, JL
    THIBODEAU, JA
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1986, 20 (09): : 1263 - 1275
  • [6] BUNDY K, 1993, T 39 ORTH RES SOC SA
  • [7] BUNDY K, 1991, T 17 ANN SOC BIOM SC
  • [8] BUNDY K, 1992, T 17 SOC BIOM SCOTTS
  • [9] USE OF AC IMPEDANCE METHODS TO STUDY THE CORROSION BEHAVIOR OF IMPLANT ALLOYS
    BUNDY, KJ
    DILLARD, J
    LUEDEMANN, R
    [J]. BIOMATERIALS, 1993, 14 (07) : 529 - 536
  • [10] SUBMERGED LAMINAR JET IMPINGEMENT ON A PLANE
    DESHPANDE, MD
    VAISHNAV, RN