Synthesis of 12-Lead ECG from a Reduced Lead Set using Singular Value Decomposition

被引:0
作者
Padhy, Sibasankar [1 ]
Dandapat, S. [1 ]
机构
[1] Indian Inst Technol Guwahati, Dept Elect & Elect Engn, Gauhati 781039, Assam, India
来源
2015 IEEE POWER, COMMUNICATION AND INFORMATION TECHNOLOGY CONFERENCE (PCITC-2015) | 2015年
关键词
Electrocardiogram (ECG); Signular Value Decomposition (SVD); reduced lead set; percent correlation coefficient; PRD; WEDD; COMPRESSION; ELECTROCARDIOGRAM; RECONSTRUCTION;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents synthesis of 12-lead Electrocardiogram (ECG) from a reduced set of leads. A patient-specific 12-lead ECG is trained using the Singular Value Decomposition (SVD) for minimum of three beat periods. Then, in the testing stage, different reduced lead sets comprising of three leads are used to reconstruct all other leads. The singular value matrix of the reduced 3-lead data is transformed to a higher dimension using a transform matrix. For evaluation purpose, the proposed method is applied to a publicly available database. It contains number of 12-lead ECG recordings with different cardiac patients' data. The proposed method performs well for reconstruction of precordial leads in case of myocardial infarction. The percent correlation exceeds 97% for most of the precordial leads. After reconstruction of 12-lead ECG data, the performance of the method is measured using three measures namely percent correlation, PRD and WEDD between the original and the synthesized data.
引用
收藏
页码:316 / 320
页数:5
相关论文
共 17 条
[1]   Quality assessment of ECG compression techniques using a wavelet-based diagnostic measure [J].
Al-Fahoum, AS .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2006, 10 (01) :182-191
[2]  
[Anonymous], 2008, CHOUS ELECTROCARDIOG
[3]  
Clifford GD, 2006, ENG MED BIOL
[4]   PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220
[5]  
Guillem M., 2006, P 2006 COMP CARD VAL, P249
[6]   On designing and testing transformations for derivation of standard 12-lead/18-lead electrocardiograms and vectorcardiograms from reduced sets of predictor leads [J].
Horacek, B. Milan ;
Warren, James W. ;
Wang, John J. .
JOURNAL OF ELECTROCARDIOLOGY, 2008, 41 (03) :220-229
[7]   Wavelet energy based diagnostic distortion measure for ECG [J].
Manikandan, A Sabarimalai ;
Dandapat, S. .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2007, 2 (02) :80-96
[8]   A NEW SYSTEM OF MULTIPLE-LEAD EXERCISE ELECTROCARDIOGRAPHY [J].
MASON, RE ;
LIKAR, I .
AMERICAN HEART JOURNAL, 1966, 71 (02) :196-&
[9]   Reconstruction of the 12-lead electrocardiogram from reduced lead sets [J].
Nelwan, SP ;
Kors, JA ;
Meij, SH ;
van Bemmel, JH ;
Simoons, ML .
JOURNAL OF ELECTROCARDIOLOGY, 2004, 37 (01) :11-18
[10]  
Ostertag MH, 2011, IEEE ENG MED BIO, P4414, DOI 10.1109/IEMBS.2011.6091095