An evaluation of the "GGP" personal samplers under semi-volatile aerosols: sampling losses and their implication on occupational risk assessment

被引:11
作者
Dragan, George C. [1 ,2 ]
Breuer, Dietmar [3 ]
Blaskowitz, Morten [3 ]
Karg, Erwin [1 ,4 ]
Schnelle-Kreis, Juergen [1 ,4 ]
Arteaga-Salas, Jose M. [1 ,4 ]
Nordsieck, Hermann [5 ]
Zimmermann, Ralf [1 ,2 ,4 ]
机构
[1] Helmholtz Zentrum Munchen, Joint Mass Spectrometry Ctr, Cooperat Grp Comprehens Mol Analyt, D-85758 Neuherberg, Germany
[2] Univ Rostock, Inst Chem, Joint Mass Spectrometry Ctr, Chair Analyt Chem, D-18057 Rostock, Germany
[3] German Social Accid Insurance, Inst Occupat Safety & Hlth, D-53757 St Augustin, Germany
[4] Helmholtz Virtual Inst Complex Mol Syst Environm, Berlin, Germany
[5] Bifa Environm Inst, D-86167 Augsburg, Germany
关键词
METALWORKING FLUID AEROSOLS; OIL MIST CONCENTRATIONS; SIZE DISTRIBUTION; FIBROUS FILTERS; INORGANIC ACIDS; WORKPLACE AIR; PART; EXPOSURE; VAPOR; WORKERS;
D O I
10.1039/c4em00468j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Semi-volatile (SV) aerosols still represent an important challenge to occupational hygienists due to toxicological and sampling issues. Particularly problematic is the sampling of hazardous SV that are present in both particulate and vapour phases at a workplace. In this study we investigate the potential evaporation losses of SV aerosols when using off-line filter-adsorber personal samplers. Furthermore, we provide experimental data showing the extent of the evaporation loss that can bias the workplace risk assessment. An experimental apparatus consisting of an aerosol generator, a flow tube and an aerosol monitoring and sampling system was set up inside a temperature controlled chamber. Aerosols from three n-alkanes were generated, diluted with nitrogen and sampled using on-line and off-line filter-adsorber methods. Parallel measurements using the on-line and off-line methods were conducted to quantify the bias induced by filter sampling. Additionally, two mineral oils of different volatility were spiked on filters and monitored for evaporation depending on the samplers flow rate. No significant differences between the on-line and off-line methods were detected for the sum of particles and vapour. The filter-adsorber method however tended to underestimate up to 100% of the particle mass, especially for the more volatile compounds and lower concentrations. The off-line sampling method systematically returned lower particle and higher vapour values, an indication for particle evaporation losses. We conclude that using only filter sampling for the assessment of semi-volatiles may considerably underestimate the presence of the particulate phase due to evaporation. Thus, this underestimation can have a negative impact on the occupational risk assessment if the evaporated particle mass is no longer quantified.
引用
收藏
页码:270 / 277
页数:8
相关论文
共 49 条
  • [1] [Anonymous], 2004, BBC NEWS
  • [2] Cutting fluid aerosol from splash in turning: Analysis for environmentally conscious machining
    Atmadi, A
    Stephenson, DA
    Liang, SY
    [J]. INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2001, 17 (04) : 238 - 243
  • [3] Performance of methods for measurement of exposure to inorganic acids in workplace air
    Breuer, D
    Howe, A
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2006, 8 (01): : 120 - 126
  • [4] Breuer D, 2014, GEFAHRST REINHALT L, V74, P129
  • [5] Measurement of vapour-aerosol mixtures?
    Breuer, D
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (04): : 299 - 305
  • [6] Sulfuric acid at workplaces-applicability of the new Indicative Occupational Exposure Limit Value (IOELV) to thoracic particles
    Breuer, Dietmar
    Heckmann, Petra
    Gusbeth, Krista
    Schwab, Gregoria
    Blaskowitz, Morten
    Moritz, Andreas
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2012, 14 (02): : 440 - 445
  • [7] Air sampling and determination of vapours and aerosols of bitumen and polycyclic aromatic hydrocarbons in the Human Bitumen Study
    Breuer D.
    Hahn J.-U.
    Höber D.
    Emmel C.
    Musanke U.
    Rühl R.
    Spickenheuer A.
    Raulf-Heimsoth M.
    Bramer R.
    Seidel A.
    Schilling B.
    Heinze E.
    Kendzia B.
    Marczynski B.
    Welge P.
    Angerer J.
    Brüning T.
    Pesch B.
    [J]. Archives of Toxicology, 2011, 85 (Suppl 1) : S11 - S20
  • [8] Calvert GM, 1998, AM J IND MED, V33, P282, DOI 10.1002/(SICI)1097-0274(199803)33:3<282::AID-AJIM10>3.0.CO
  • [9] 2-W
  • [10] Metalworking fluid mist occupational exposure limits: A discussion of alternative methods
    Cohen, Howard
    White, Eugene M.
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2006, 3 (09) : 501 - 507