Can Dual Mobility Cups prevent Dislocation in All Situations After Revision Total Hip Arthroplasty?

被引:68
作者
Wegrzyn, Julien [1 ,2 ]
Tebaa, Eloise [1 ]
Jacque, Alexandre [1 ]
Carret, Jean-Paul [1 ]
Bejui-Hugues, Jacques [1 ]
Pibarot, Vincent [1 ]
机构
[1] Hop Edouard Herriot, Dept Orthoped Surg Pavillon T, F-69437 Lyon, France
[2] Univ Lyon, INSERM, UMR 1033, Lyon, France
关键词
revision; total hip arthroplasty; dual mobility cup; dislocation; intra-prosthetic dislocation; ACETABULAR COMPONENT; RISK-FACTORS; THA; IMPLANTS; CLASSIFICATION; INSTABILITY; MANAGEMENT; ALLOGRAFT; FAILURE; LINERS;
D O I
10.1016/j.arth.2014.10.034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The outcome of a single design of dual mobility cup was prospectively evaluated in a continuous series of 994 revision THAs with respect to dislocation and intra-prosthetic dislocation (IPD). At a 7.3-year mean follow-up, the dislocation rate was 1.5% and the IPD rate was 0.2%. The 2 IPD occurred in acetabular-only revisions and were related to a poor head-to-neck ratio with early impingement and wear at the polyethylene mobile component chamfer. Dual mobility cups demonstrated a low dislocation rate in revision THA but did not compensate for potential perioperative technical errors. In addition, IPD did not appear to be a concern with respect to the benefit in term of instability prevention though caution is advised in acetabular-only revision associated with a poor head-to-neck ratio. Level of Evidence: Therapeutic study-Level IV (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:631 / 640
页数:10
相关论文
共 33 条
[11]  
Della Valle CJ, 2004, CLIN ORTHOP RELAT R, P55
[12]   The Frank Stinchfield Award: Dislocation in Revision THA: Do Large Heads (36 and 40 mm) Result in Reduced Dislocation Rates in a Randomized Clinical Trial? [J].
Garbuz, Donald S. ;
Masri, Bassam A. ;
Duncan, Clive P. ;
Greidanus, Nelson V. ;
Bohm, Eric R. ;
Petrak, Martin J. ;
Della Valle, Craig J. ;
Gross, Allan E. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) :351-356
[13]   Modes of failure of osteonics constrained tripolar implants: A retrospective analysis of forty-three failed implants [J].
Guyen, Olivier ;
Lewallen, David G. ;
Cabanela, Miguel E. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (07) :1553-1560
[14]   Unconstrained tripolar hip implants - Effect on hip stability [J].
Guyen, Olivier ;
Chen, Qing Shan ;
Bejui-Hugues, Jacques ;
Berry, Daniel J. ;
An, Kai-Nan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (455) :202-208
[15]   Use of a Dual Mobility Socket to Manage Total Hip Arthroplasty Instability [J].
Guyen, Olivier ;
Pibarot, Vincent ;
Vaz, Gualter ;
Chevillotte, Christophe ;
Bejui-Hugues, Jacques .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (02) :465-472
[16]   Dual-mobility cups for revision due to instability are associated with a low rate of re-revisions due to dislocation 228 patients from the Swedish Hip Arthroplasty Register [J].
Hailer, Nils P. ;
Weiss, Rudiger J. ;
Stark, Andre ;
Karrholm, Johan .
ACTA ORTHOPAEDICA, 2012, 83 (06) :566-571
[17]   Megaprostheses for the treatment of malignantbone tumours of the lower limbs [J].
Heisel, Christian ;
Kinkel, Stefan ;
Bernd, Ludger ;
Ewerbeck, Volker .
INTERNATIONAL ORTHOPAEDICS, 2006, 30 (06) :452-457
[18]   Dislocation after the first and multiple revision total hip arthroplasty: comparison between acetabulum-only, femur-only and both component revision hip arthroplasty [J].
Kosashvili, Yona ;
Drexler, Michael ;
Backstein, David ;
Safir, Oleg ;
Lakstein, Dror ;
Safir, Alex ;
Chakravertty, Raja ;
Dwyer, Tim ;
Gross, Allan .
CANADIAN JOURNAL OF SURGERY, 2014, 57 (02) :E15-E18
[19]   Effect of femoral head size and abductors on dislocation after revision THA [J].
Kung, Peter L. ;
Ries, Michael D. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) :170-174
[20]  
Lachiewicz Paul F, 2002, J Am Acad Orthop Surg, V10, P233