Optimized 3D co-registration of ultra-low-field and high-field magnetic resonance images

被引:9
|
作者
Guidotti, Roberto [1 ,2 ]
Sinibaldi, Raffaele [1 ,2 ]
De Luca, Cinzia [1 ,2 ]
Conti, Allegra [1 ,2 ]
Ilmoniemi, Risto J. [3 ]
Zevenhoven, Koos C. J. [3 ]
Magnelind, Per E. [4 ]
Pizzella, Vittorio [1 ,2 ]
Del Gratta, Cosimo [1 ,2 ]
Romani, Gian Luca [1 ,2 ]
Della Penna, Stefania [1 ,2 ,5 ]
机构
[1] Dept Neurosci Imaging & Clin Sci, Chieti, Italy
[2] Univ G DAnnunzio Chieti & Pescara, Inst Adv Biomed Technol, Chieti, Italy
[3] Aalto Univ, Sch Sci, Dept Neurosci & Biomed Engn, Aalto, Finland
[4] Los Alamos Natl Lab, Phys Div MS D454, Appl Modern Phys Grp, Los Alamos, NM USA
[5] Univ Chieti Pescara G DAnnunzio, UOS Aquila, Sede Lavoro CNR SPIN, Ist SPIN,Consiglio Nazl Ric, Chieti, Italy
来源
PLOS ONE | 2018年 / 13卷 / 03期
关键词
MICROTESLA MRI; HUMAN BRAIN; MAGNETOENCEPHALOGRAPHY; ROBUST;
D O I
10.1371/journal.pone.0193890
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The prototypes of ultra-low-field (ULF) MRI scanners developed in recent years represent new, innovative, cost-effective and safer systems, which are suitable to be integrated in multi-modal (Magnetoencephalography and MRI) devices. Integrated ULF-MRI and MEG scanners could represent an ideal solution to obtain functional (MEG) and anatomical (ULF MRI) information in the same environment, without errors that may limit source reconstruction accuracy. However, the low resolution and signal-to-noise ratio (SNR) of ULF images, as well as their limited coverage, do not generally allow for the construction of an accurate individual volume conductor model suitable for MEG localization. Thus, for practical usage, a high-field (HF) MRI image is also acquired, and the HF-MRI images are co-registered to the ULF-MRI ones. We address here this issue through an optimized pipeline (SWIM-Sliding WIndow grouping supporting Mutual information). The co-registration is performed by an affine transformation, the parameters of which are estimated using Normalized Mutual Information as the cost function, and Adaptive Simulated Annealing as the minimization algorithm. The sub-voxel resolution of the ULF images is handled by a sliding-window approach applying multiple grouping strategies to down-sample HF MRI to the ULF-MRI resolution. The pipeline has been tested on phantom and real data from different ULF-MRI devices, and comparison with well-known toolboxes for fMRI analysis has been performed. Our pipeline always outperformed the fMRI toolboxes (FSL and SPM). The HF-ULF MRI co-registration obtained by means of our pipeline could lead to an effective integration of ULF MRI with MEG, with the aim of improving localization accuracy, but also to help exploit ULF MRI in tumor imaging.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Development of Ultra-Low Field Magnetic Resonance Imaging System at 1 mT
    Oyama D.
    Tsuyuguchi N.
    Hirama J.
    Adachi Y.
    Kawai J.
    Journal of the Magnetics Society of Japan, 2023, 47 (04) : 118 - 127
  • [32] Windows on the Human Body - in Vivo High-Field Magnetic Resonance Research and Applications in Medicine and Psychology
    Moser, Ewald
    Meyerspeer, Martin
    Fischmeister, Florian Ph. S.
    Grabner, Guenther
    Bauer, Herbert
    Trattnig, Siegfried
    SENSORS, 2010, 10 (06) : 5724 - 5757
  • [33] Adaptive suppression of power line interference in ultra-low field magnetic resonance imaging in an unshielded environment
    Huang, Xiaolei
    Dong, Hui
    Qiu, Yang
    Li, Bo
    Tao, Quan
    Zhang, Yi
    Krause, Hans-Joachim
    Offenhaeusser, Andreas
    Xie, Xiaoming
    JOURNAL OF MAGNETIC RESONANCE, 2018, 286 : 52 - 59
  • [34] Monopole Antenna Array with Individual Shields for Ultra High Field Magnetic Resonance Imaging
    Kausar, A. S. M. Zahid
    Reutens, David C.
    Weber, Ewald
    Vegh, Viktor
    2018 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS-TOYAMA), 2018, : 1044 - 1050
  • [35] Accelerated mapping of magnetic susceptibility using 3D planes-on-apaddlewheel (POP) EPI at ultra-high field strength
    Staeb, Daniel
    Bollmanna, Steffen
    Langkammer, Christian
    Bredies, Kristian
    Barth, Markus
    NMR IN BIOMEDICINE, 2017, 30 (04)
  • [36] Dedicated container for postmortem human brain ultra-high field magnetic resonance imaging
    Boonstra, Jackson Tyler
    Michielse, Stijn
    Roebroeck, Alard
    Temel, Yasin
    Jahanshahi, Ali
    NEUROIMAGE, 2021, 235
  • [37] Ownership protection for light-field 3D images: HDCT watermarking
    Li, Xiaowei
    Ren, Zhiqing
    Wang, Tianhao
    Deng, Huan
    OPTICS EXPRESS, 2021, 29 (26) : 43256 - 43269
  • [38] Imaging of the Musculoskeletal System In Vivo Using Ultra-high Field Magnetic Resonance at 7 T
    Krug, Roland
    Stehling, Christoph
    Kelley, Douglas A. C.
    Majumdar, Sharmila
    Link, Thomas M.
    INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 613 - 618
  • [39] An intra-neural microstimulation system for ultra-high field magnetic resonance imaging and magnetoencephalography
    Glover, Paul M.
    Watkins, Roger H.
    O'Neill, George C.
    Ackerley, Rochelle
    Sanchez-Panchuelo, Rosa
    McGlone, Francis
    Brookes, Matthew J.
    Wessberg, Johan
    Francis, Susan T.
    JOURNAL OF NEUROSCIENCE METHODS, 2017, 290 : 69 - 78
  • [40] Forging a path to mesoscopic imaging success with ultra-high field functional magnetic resonance imaging
    Weldon, Kimberly B.
    Olman, Cheryl A.
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2021, 376 (1815)