Optimized 3D co-registration of ultra-low-field and high-field magnetic resonance images

被引:9
|
作者
Guidotti, Roberto [1 ,2 ]
Sinibaldi, Raffaele [1 ,2 ]
De Luca, Cinzia [1 ,2 ]
Conti, Allegra [1 ,2 ]
Ilmoniemi, Risto J. [3 ]
Zevenhoven, Koos C. J. [3 ]
Magnelind, Per E. [4 ]
Pizzella, Vittorio [1 ,2 ]
Del Gratta, Cosimo [1 ,2 ]
Romani, Gian Luca [1 ,2 ]
Della Penna, Stefania [1 ,2 ,5 ]
机构
[1] Dept Neurosci Imaging & Clin Sci, Chieti, Italy
[2] Univ G DAnnunzio Chieti & Pescara, Inst Adv Biomed Technol, Chieti, Italy
[3] Aalto Univ, Sch Sci, Dept Neurosci & Biomed Engn, Aalto, Finland
[4] Los Alamos Natl Lab, Phys Div MS D454, Appl Modern Phys Grp, Los Alamos, NM USA
[5] Univ Chieti Pescara G DAnnunzio, UOS Aquila, Sede Lavoro CNR SPIN, Ist SPIN,Consiglio Nazl Ric, Chieti, Italy
来源
PLOS ONE | 2018年 / 13卷 / 03期
关键词
MICROTESLA MRI; HUMAN BRAIN; MAGNETOENCEPHALOGRAPHY; ROBUST;
D O I
10.1371/journal.pone.0193890
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The prototypes of ultra-low-field (ULF) MRI scanners developed in recent years represent new, innovative, cost-effective and safer systems, which are suitable to be integrated in multi-modal (Magnetoencephalography and MRI) devices. Integrated ULF-MRI and MEG scanners could represent an ideal solution to obtain functional (MEG) and anatomical (ULF MRI) information in the same environment, without errors that may limit source reconstruction accuracy. However, the low resolution and signal-to-noise ratio (SNR) of ULF images, as well as their limited coverage, do not generally allow for the construction of an accurate individual volume conductor model suitable for MEG localization. Thus, for practical usage, a high-field (HF) MRI image is also acquired, and the HF-MRI images are co-registered to the ULF-MRI ones. We address here this issue through an optimized pipeline (SWIM-Sliding WIndow grouping supporting Mutual information). The co-registration is performed by an affine transformation, the parameters of which are estimated using Normalized Mutual Information as the cost function, and Adaptive Simulated Annealing as the minimization algorithm. The sub-voxel resolution of the ULF images is handled by a sliding-window approach applying multiple grouping strategies to down-sample HF MRI to the ULF-MRI resolution. The pipeline has been tested on phantom and real data from different ULF-MRI devices, and comparison with well-known toolboxes for fMRI analysis has been performed. Our pipeline always outperformed the fMRI toolboxes (FSL and SPM). The HF-ULF MRI co-registration obtained by means of our pipeline could lead to an effective integration of ULF MRI with MEG, with the aim of improving localization accuracy, but also to help exploit ULF MRI in tumor imaging.
引用
收藏
页数:19
相关论文
共 50 条
  • [11] Ultra high-field (7tesla) magnetic resonance spectroscopy in Amyotrophic Lateral Sclerosis
    Atassi, Nazem
    Xu, Maosheng
    Triantafyllou, Christina
    Keil, Boris
    Lawson, Robert
    Cernasov, Paul
    Ratti, Elena
    Long, Christopher J.
    Paganoni, Sabrina
    Murphy, Alyssa
    Salibi, Nouha
    Seethamraju, Ravi
    Rosen, Bruce
    Ratai, Eva-Maria
    PLOS ONE, 2017, 12 (05):
  • [12] AUTOMATIC CO-REGISTRATION OF MEG AND 3D DIGITIZATION USING 3D GENERALIZED HOUGH TRANSFORM
    Lin, Sheng-Kai
    Lo, Rong-Chin
    Lee, Ren-Guey
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2020, 32 (03):
  • [13] Optimized partial-coverage functional analysis pipeline (OPFAP): a semi-automated pipeline for skull stripping and co-registration of partial-coverage, ultra-high-field functional images
    Yoo, Peter E.
    Cleary, Jon O.
    Kolbe, Scott C.
    Ordidge, Roger J.
    O'Brien, Terence J.
    Opie, Nicholas L.
    John, Sam E.
    Oxley, Thomas J.
    Moffat, Bradford A.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2018, 31 (05) : 621 - 632
  • [14] High-field magnetic resonance imaging of the human temporal lobe
    Colon-Perez, Luis M.
    King, Michael
    Parekh, Mansi
    Boutzoukas, Angelique
    Carmona, Eduardo
    Couret, Michelle
    Klassen, Rosemary
    Mareci, Thomas H.
    Carney, Paul R.
    NEUROIMAGE-CLINICAL, 2015, 9 : 58 - 68
  • [15] Editorial: In Vivo Magnetic Resonance at Ultra High Field
    Zhu, He
    Moser, Ewald
    FRONTIERS IN PHYSICS, 2017, 5
  • [16] Low-field and high-field magnetic resonance contrast imaging of magnetoferritin as a pathological model system of iron accumulation
    Strbak, Oliver
    Balejcikova, Lucia
    Baciak, Ladislav
    Kovac, Jozef
    Masarova-Kozelova, Marta
    Krafcik, Andrej
    Dobrota, Dusan
    Kopcansky, Peter
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2017, 50 (36)
  • [17] Parallel Transmit and Receive Technology in High-Field Magnetic Resonance Neuroimaging
    Webb, Andrew G.
    Collins, Christopher M.
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2010, 20 (01) : 2 - 13
  • [18] MEG-MRI CO-REGISTRATION USING 3D GENERALIZED HOUGH TRANSFORM
    Lin, Sheng-Kai
    Lo, Rong-Chin
    Lee, Ren-Guey
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2020, 32 (04):
  • [19] SQUID-sensor-based ultra-low-field MRI calibration with phantom images: Towards quantitative imaging
    Dabek, Juhani
    Vesanen, Panu T.
    Zevenhoven, Koos C. J.
    Nieminen, Jaakko O.
    Sepponen, Raimo
    Ilmoniemi, Risto J.
    JOURNAL OF MAGNETIC RESONANCE, 2012, 224 : 22 - 31
  • [20] MAGNETOENCEPHALOGRAPHY-ELECTROENCEPHALOGRAPHY CO-REGISTRATION USING 3D GENERALIZED HOUGH TRANSFORM
    Lin, Sheng-Kai
    Lo, Rong-Chin
    Lee, Ren-Guey
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2020, 32 (03):