Qualitative and quantitative evaluation of heart sound reduction from lung sound recordings

被引:16
作者
Gnitecki, J
Hossain, I
Pasterkamp, H
Moussavi, Z [1 ]
机构
[1] Univ Manitoba, Dept Elect & Comp Engn, Winnipeg, MB R3T 5V6, Canada
[2] Wayne State Univ, Dept Elect & Comp Engn, Detroit, MI 48202 USA
[3] Univ Manitoba, Dept Pediat, Winnipeg, MB R3E 3PA, Canada
[4] Manitoba Inst Child Hlth, Winnipeg, MB R3E 3PA, Canada
关键词
adaptive noise cancellation; heart sounds; lung sounds; recursive least squares; wavelet denoising;
D O I
10.1109/TBME.2005.855706
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recursive least squares (RLS) adaptive noise cancellation (ANC) and wavelet transform (WT) ANC have been applied and compared for heart sound (HS) reduction from lung sounds (LS) recordings. Novel processes for quantitative and qualitative evaluation of any method for HS reduction from LS have also been proposed.
引用
收藏
页码:1788 / 1792
页数:5
相关论文
共 18 条
[1]   Interference cancellation in respiratory sounds via a multiresolution joint time-delay and signal-estimation scheme [J].
Charleston, S ;
AzimiSadjadi, MR ;
GonzalezCamarena, R .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (10) :1006-1019
[2]   Reduced order Kalman filtering for the enhancement of respiratory sounds [J].
Charleston, S ;
AzimiSadjadi, MR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (04) :421-424
[3]   ADOPTED WAVE-FORM DE NOISING FOR MEDICAL SIGNALS AND IMAGES [J].
COIFMAN, RR ;
WICKERHAUSER, MV .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (05) :578-586
[4]   ORTHONORMAL BASES OF COMPACTLY SUPPORTED WAVELETS [J].
DAUBECHIES, I .
COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 1988, 41 (07) :909-996
[5]   Separation of discontinuous adventitious sounds from vesicular sounds using a wavelet-based filter [J].
Hadjileontiadis, LJ ;
Panas, SM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) :1269-1281
[6]  
Hadjileontiadis LJ, 1998, INT J MED INFORM, V52, P183, DOI 10.1016/S1386-5056(98)00137-3
[7]   Adaptive reduction of heart sounds from lung sounds using fourth-order statistics [J].
Hadjileontiadis, LJ ;
Panas, SM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (07) :642-648
[8]   Sensor system for heart sound biomonitor [J].
Hall, LT ;
Maple, JL ;
Agzarian, J ;
Abbott, D .
MICROELECTRONICS JOURNAL, 2000, 31 (07) :583-592
[9]  
Haykin S., 2002, ADAPTIVE FILTER THEO
[10]   REDUCTION OF HEART SOUNDS FROM LUNG SOUNDS BY ADAPTIVE FILTERING [J].
IYER, VK ;
RAMAMOORTHY, PA ;
HONG, F ;
PLOYSONGSANG, Y .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (12) :1141-1148