INbreast: Toward a Full-field Digital Mammographic Database

被引:696
|
作者
Moreira, Ines C. [1 ,2 ,3 ,4 ]
Amaral, Igor [3 ]
Domingues, Ines [3 ,5 ]
Cardoso, Antonio [2 ]
Cardoso, Maria Joao [1 ,3 ,6 ]
Cardoso, Jaime S. [3 ,5 ]
机构
[1] Univ Porto, Fac Med, P-4200319 Oporto, Portugal
[2] Hosp Sao Joao, Oporto, Portugal
[3] INESC Porto, Oporto, Portugal
[4] Politecn Porto, Escola Super Tecnol Saude Porto, Oporto, Portugal
[5] Univ Porto, Fac Engn, P-4200319 Oporto, Portugal
[6] Champalimaud Canc Ctr, Breast Unit, Lisbon, Portugal
关键词
Mammographic database; CAD; computer-aided detection; computer-aided diagnosis; COMPUTER-AIDED DETECTION; CONTRAST ENHANCEMENT; BREAST-MASSES; SEGMENTATION; MICROCALCIFICATIONS; CLASSIFICATION; IMAGES;
D O I
10.1016/j.acra.2011.09.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Computer-aided detection and diagnosis (CAD) systems have been developed in the past two decades to assist radiologists in the detection and diagnosis of lesions seen on breast imaging exams, thus providing a second opinion. Mammographic databases play an important role in the development of algorithms aiming at the detection and diagnosis of mammary lesions. However, available databases often do not take into consideration all the requirements needed for research and study purposes. This article aims to present and detail a new mammographic database. Materials and Methods: Images were acquired at a breast center located in a university hospital (Centro Hospitalar de S. Joao [CHSJ], Breast Centre, Porto) with the permission of the Portuguese National Committee of Data Protection and Hospital's Ethics Committee. MammoNovation Siemens full-field digital mammography, with a solid-state detector of amorphous selenium was used. Results: The new database-INbreast-has a total of 115 cases (410 images) from which 90 cases are from women with both breasts affected (four images per case) and 25 cases are from mastectomy patients (two images per case). Several types of lesions (masses, calcifications, asymmetries, and distortions) were included. Accurate contours made by specialists are also provided in XML format. Conclusion: The strengths of the actually presented database-INbreast-relies on the fact that it was built with full-field digital mammograms (in opposition to digitized mammograms), it presents a wide variability of cases, and is made publicly available together with precise annotations. We believe that this database can be a reference for future works centered or related to breast cancer imaging.
引用
收藏
页码:236 / 248
页数:13
相关论文
共 50 条
  • [11] Evaluation of Lossy Data Compression in Primary Interpretation for Full-Field Digital Mammography
    Kovacs, Mark D.
    Reicher, Joshua J.
    Grotts, Jonathan F.
    Reicher, Murray A.
    Trambert, Michael A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : 570 - 575
  • [12] Quantitative comparison of clustered microcalcifications in for-presentation and for-processing mammograms in full-field digital mammography
    Wang, Juan
    Nishikawa, Robert M.
    Yang, Yongyi
    MEDICAL PHYSICS, 2017, 44 (07) : 3726 - 3738
  • [13] CAD in full-field digital mammography-influence of reader experience and application of CAD on interpretation of time
    Sohns, Christian
    Angic, Besim Cetin
    Sossalla, Samuel
    Konietschke, Frank
    Obenauer, Silvia
    CLINICAL IMAGING, 2010, 34 (06) : 418 - 424
  • [14] Impact of type of full-field digital image on mammographic density assessment and breast cancer risk estimation: a case-control study
    Busana, Marta Cecilia
    Eng, Amanda
    Denholm, Rachel
    Dowsett, Mitch
    Vinnicombe, Sarah
    Allen, Steve
    dos-Santos-Silva, Isabel
    BREAST CANCER RESEARCH, 2016, 18
  • [15] Computer-aided detection in direct digital full-field mammography: initial results
    Baum, F
    Fischer, U
    Obenauer, S
    Grabbe, E
    EUROPEAN RADIOLOGY, 2002, 12 (12) : 3015 - 3017
  • [16] Factors affecting the rate of false positive marks in CAD in full-field digital mammography
    Engelken, Florian
    Bremme, Raphael
    Bick, Ulrich
    Hammann-Kloss, Sophie
    Fallenberg, Eva M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (08) : E844 - E848
  • [17] Comparison of slot scanning digital mammography system with full-field digital mammography system
    Lai, Chao-Jen
    Shaw, Chris C.
    Geiser, William
    Chen, Lingyun
    Arribas, Elsa
    Stephens, Tanya
    Davis, Paul L.
    Ayyar, Geetha P.
    Dogan, Basak E.
    Nguyen, Victoria A.
    Whitman, Gary J.
    Yang, Wei T.
    MEDICAL PHYSICS, 2008, 35 (06) : 2339 - 2346
  • [18] Digital zoom of the full-field digital mammogram versus magnification mammography: a systematic review
    Oynes, Mona
    Strom, Bergliot
    Tveito, Bente
    Hafslund, Bjorg
    EUROPEAN RADIOLOGY, 2020, 30 (08) : 4223 - 4233
  • [19] Women's features and inter-/intra-rater agreement on mammographic density assessment in full-field digital mammograms (DDM-SPAIN)
    Perez-Gomez, Beatriz
    Ruiz, Franciso
    Martinez, Inmaculada
    Casals, Maria
    Miranda, Josefa
    Sanchez-Contador, Carmen
    Vidal, Carmen
    Llobet, Rafael
    Pollan, Marina
    Salas, Dolores
    BREAST CANCER RESEARCH AND TREATMENT, 2012, 132 (01) : 287 - 295
  • [20] Computer-aided detection in full-field digital mammography in a clinical population: performance of radiologist and technologists
    Frank J. H. M. van den Biggelaar
    Alphons G. H. Kessels
    Jos M. A. van Engelshoven
    Carla Boetes
    Karin Flobbe
    Breast Cancer Research and Treatment, 2010, 120 : 499 - 506