Dual-Frequency Chirp Excitation for Passive Cavitation Imaging in the Brain

被引:4
作者
Lin, Hsiang-Ching [1 ]
Fan, Ching-Hsiang [1 ]
Ho, Yi-Ju [1 ]
Yeh, Chih-Kuang [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Biomed Engn & Environm Sci, Hsinchu 30013, Taiwan
关键词
Blood-brain barrier (BBB); dual-frequency chirp (DFC) excitation; microbubbles (MBs); passive cavitation imaging (PCI); ultrasound (US); GUIDED FOCUSED ULTRASOUND; BARRIER DISRUPTION; RESONANCE FREQUENCY; MICROBUBBLES; DEPENDENCE; PERMEABILITY; DOXORUBICIN; DELIVERY; DRUG;
D O I
10.1109/TUFFC.2020.2964786
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
One of the main challenges that impede cavitation-mediated imaging in the brain is restricted opening of the blood-brain barrier (BBB) making it difficult to locate cavitating microbubbles (MBs). Passive cavitation imaging (PCI) has received attention due to the possibility of performing real-time monitoring by listening to acoustic cavitation. However, the long excitation pulses associated with PCI degradeits axial resolution. The present study combined a coded excitation technique with a dual-frequency chirp (DFC) excitation method to prevent interference from the nonlinear components of MBs' cavitation. The use of DFC excitation generates a low-frequency (0.4, 0.5, or 0.6 MHz) chirp component as the envelope of the signal-driving MBs' cavitation with a dual-frequency pulse (omega 1 = 1.35 MHz and omega 2 = 1.65 MHz, omega 1 = 1.3 MHz and omega 2 = 1.7 MHz, and omega 1 = 1.25 MHz and omega 2 = 1.75 MHz). The cavitation of MBs was passively imaged utilizing a chirp component with pulse compression to maintain abundant insonation energy without any reduction in the axial imaging resolution. In vitro experiments showed that the DFC method improved the signal-to-noise ratio by 42.2% and the axial resolution by 4.1-fold compared with using a conventional long-pulse waveform. Furthermore, the cavitating MBs driven by different ultrasound (US) energy (0, 0.3, 0.6, and 0.9 MPa, N = 3 for each group) in the rat brain with an intact skull still could be mapped by DFC. Our successful demonstration of using the DFC method to image cavitation-induced BBB opening affords an alternative tool for assessing cavitation-dependent drug delivery to the brain, with the benefit of real-time and high convenient integration with current US imaging devices.
引用
收藏
页码:1127 / 1140
页数:14
相关论文
共 50 条
  • [41] Nonlinear effects of dual-frequency focused ultrasound on the on-demand regulation of acoustic droplet vaporization
    Zhao, Yubo
    Feng, Yi
    Wu, Liang
    ULTRASONICS SONOCHEMISTRY, 2024, 104
  • [42] Dual-frequency setting for urinary stone fragmentation during shock wave lithotripsy: an in vitro study
    Han, Christopher S.
    Vetter, Joel M.
    Endicott, Robert
    Chevinsky, Michael
    Zafar, Affan
    Venkatesh, Ramakrishna
    UROLITHIASIS, 2020, 48 (04) : 369 - 375
  • [43] VISUALIZATION OF MICROVASCULAR ANGIOGENESIS USING DUAL-FREQUENCY CONTRAST-ENHANCED ACOUSTIC ANGIOGRAPHY: A REVIEW
    Newsome, Isabel G.
    Dayton, Paul A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (10) : 2625 - 2635
  • [44] Effect of fractionation on treatment outcome in local dual-frequency sonication and Dox-encapsulated nanomicelles
    Hadi Hasanzadeh
    Manijhe Mokhtari-Dizaji
    S. Zahra Bathaie
    Zuhair M. Hassan
    Journal of Medical Ultrasonics, 2013, 40 : 303 - 308
  • [45] Chirp- and random-based coded ultrasonic excitation for localized blood-brain barrier opening
    Kamimura, H. A. S.
    Wang, S.
    Wu, S-Y
    Karakatsani, M. E.
    Acosta, C.
    Carneiro, A. A. O.
    Konofagou, E. E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (19) : 7695 - 7712
  • [46] Measuring Lift-Off Distance and Electromagnetic Property of Metal Using Dual-Frequency Linearity Feature
    Lu, Mingyang
    Meng, Xiaobai
    Huang, Ruochen
    Chen, Liming
    Peyton, Anthony
    Yin, Wuliang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [47] On-demand regulation and enhancement of the nucleation in acoustic droplet vaporization using dual-frequency focused ultrasound
    Zhao, Yubo
    Qin, Dui
    Chen, Junjie
    Hou, Jin
    Ilovitsh, Tali
    Wan, Mingxi
    Wu, Liang
    Feng, Yi
    ULTRASONICS SONOCHEMISTRY, 2022, 90
  • [48] Implementation of a Novel 288-Element Dual-Frequency Array for Acoustic Angiography: In Vitro and In Vivo Characterization
    Newsome, Isabel G.
    Kierski, Thomas M.
    Pang, Guofeng
    Yin, Jianhua
    Yang, Jing
    Cherin, Emmanuel
    Foster, F. Stuart
    Carnevale, Claudia A.
    Demore, Christine E. M.
    Dayton, Paul A.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (08) : 2657 - 2666
  • [49] Equivalent-time-active-cavitation-imaging enables vascular-resolution blood-brain-barrier-opening-therapy planning
    Desmarais, Samuel
    Ramos-Palacios, Gerardo
    Poree, Jonathan
    Lee, Stephen A.
    Leconte, Alexis
    Sadikot, Abbas F.
    Provost, Jean
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (05)
  • [50] Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography
    Ma, Jianguo
    Martin, K. Heath
    Li, Yang
    Dayton, Paul A.
    Shung, K. Kirk
    Zhou, Qifa
    Jiang, Xiaoning
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09) : 3441 - 3457