Inconsistency in 9 mm bullets measured with non-destructive X-ray computed tomography

被引:9
|
作者
Kumar, Jagadeesha [1 ]
Landheer, Dirk [2 ]
Barnes-Warden, Jane [3 ]
Fenne, Paul [3 ]
Attridge, Alex [1 ]
Williams, Mark A. [1 ]
机构
[1] Univ Warwick, WMG, Coventry CV4 7AL, W Midlands, England
[2] Simpact Engn Ltd, Royal Leamington Spa CV31 1HP, Warwick, England
[3] Metropolitan Police Serv, London SE1 0EH, England
关键词
X-ray computed tomography; Bullet geometry; Jacket thickness; Armour standards; TERMINAL BALLISTICS; IDENTIFICATION; GEOMETRY; IMPACT;
D O I
10.1016/j.forsciint.2011.07.018
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Fundamental to any ballistic armour standard is the reference projectile that is to be defeated. Typically, for certification, consistency of bullets is assumed. Therefore, practical variations in bullet jacket dimensions can have far reaching consequences. Traditionally, internal dimensions could only be analysed by cutting bullets which rules out any subsequent ballistic assessment. Therefore, the use of a non-destructive X-ray computed tomography (CT) method is explored in this paper. A set of 10 bullets (9 mm DM11) was taken for analysing both intra and inter bullet jacket thickness variation. CT measurements of jacket thickness were validated with high resolution scanning electron microscope (SEM) images. An image based analysis methodology has been developed to extract the jacket thickness map and the centre of gravity. Thickness variations of the order of 200 mu m were found commonly across all the bullets along the length and an angular variation of up to 100 mu m was found in a few bullets. Jacket thickness and centre of gravity were also calculated for the same bullets after impact and the variations between the pre- and post-impacted bullets were compared, by establishing a common physical reference. The results show that the proposed CT scanning approach and subsequent image analysis method can bring out the statistical variations in bullet geometry pre- and post impact effectively. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:48 / 58
页数:11
相关论文
共 50 条
  • [41] Non-destructive determination of ginsenosides in ginseng by combined hyperspectral and X-ray techniques based on ensemble learning
    Miao, Peiqi
    Hao, Nan
    Zhao, Qian
    Ping, Jiacong
    Liu, Changqing
    FOOD CHEMISTRY, 2024, 437
  • [42] X-ray computed tomography for additive manufacturing: a review
    Thompson, A.
    Maskery, I.
    Leach, R. K.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (07)
  • [43] Visualization and evaluation of concrete damage in-service headworks by X-ray CT and non-destructive inspection methods
    Morozova, Nadezhda
    Shibano, Kazuma
    Shimamoto, Yuma
    Tayfur, Sena
    Alver, Ninel
    Suzuki, Tetsuya
    FRONTIERS IN BUILT ENVIRONMENT, 2022, 8
  • [44] Non-destructive Microstructural Evaluation of Intact and Restored Human Teeth Using Tabletop X-Ray μCT System
    Fatima, A.
    Kulkarni, V. K.
    Agrawal, A. K.
    Banda, N. R.
    Sarkar, P. S.
    Kashyap, Y.
    Shripathi, T.
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2017, 36 (01)
  • [45] Bismuth chelate as a contrast agent for X-ray computed tomography
    Fu, Ji-jun
    Guo, Jun-jie
    Qin, Ai-ping
    Yu, Xi-yong
    Zhang, Qiang
    Lei, Xue-ping
    Huang, Yu-gang
    Chen, Ming-yue
    Li, Jie-xia
    Zhang, Yu
    Liu, Jing-ping
    Dang, Yuan-ye
    Wu, Dan
    Zhao, Xiao-ya
    Lin, Zhong-xiao
    Lin, Yin-lei
    Li, Song-pei
    Zhang, Ling-yan
    JOURNAL OF NANOBIOTECHNOLOGY, 2020, 18 (01)
  • [46] Application of X-Ray Computed Tomography Technology in Gas Hydrate
    Ma, Shihui
    Zheng, Jia-nan
    Tang, Dawei
    Li, Yuanping
    Li, Qingping
    Lv, Xin
    ENERGY TECHNOLOGY, 2019, 7 (06)
  • [47] High-resolution X-ray computed tomography of impactites
    Koeberl, C
    Denison, C
    Ketcham, RA
    Reimold, WU
    JOURNAL OF GEOPHYSICAL RESEARCH-PLANETS, 2002, 107 (E10)
  • [48] MICRO X-RAY COMPUTED TOMOGRAPHY OF ADHESIVE BONDS IN WOOD
    McKinley, P. E.
    Ching, D. J.
    Kamke, F. A.
    Zauner, M.
    Xiao, X.
    WOOD AND FIBER SCIENCE, 2016, 48 : 2 - 16
  • [49] X-ray computed tomography using curvelet sparse regularization
    Wieczorek, Matthias
    Frikel, Juergen
    Vogel, Jakob
    Eggl, Elena
    Kopp, Felix
    Noel, Peter B.
    Pfeiffer, Franz
    Demaret, Laurent
    Lasser, Tobias
    MEDICAL PHYSICS, 2015, 42 (04) : 1555 - 1565
  • [50] Characterization of Coloured Gemstones by X-ray Micro Computed Tomography
    Heyn, Rene
    Rozendaal, Abraham
    Du Plessis, Anton
    Mouton, Carene
    MINERALS, 2021, 11 (02) : 1 - 16