Mixed approach for fault diagnosis and fault location of hybrid systems

被引:3
作者
Maaref, B. [1 ]
Abazi, Z. Simeu [2 ]
Dhouibi, H. [1 ]
Messaoud, H. [1 ]
Gascard, E. [2 ]
机构
[1] Natl Engn Sch Monastir, LARATSI, Monastir, Tunisia
[2] UJF Grenoble 1, CNRS, G SCOP, Grenoble INP, Grenoble, France
来源
IFAC PAPERSONLINE | 2016年 / 49卷 / 12期
关键词
Fault Diagnosis; Hybrid Systems; Bond Graph; Observer; Timed Automata; Fault Detection; Fault Isolation;
D O I
10.1016/j.ifacol.2016.07.573
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Today, the fault diagnosis remains a very important task due to its essential role in improving the dependability and also in minimizing the harmful consequences which can be catastrophic for equipment and human safety. This article proposes a diagnostic approach for hybrid systems through the use of Bond Graph and observers well known in continuous field, coupled to timed automata well used in the field of discrete events systems. Indeed, for a complex system, the Bond Graph allows modeling of multi-energy physical processes. The observer-based approach is used to generate dynamic models (in normal and in failing mode). The fault detection algorithm consists mainly in comparing the real measures of the system with measures estimated by an observer. Thus, the fault isolation procedure consists in analyzing the fault signature matrix. Timed automata allow to take into account the dynamic evolution of the system and the failures propagation. To refine the failure location, a diagnoser based on timed automaton is built. The proposed approach is validated by simulation tests in a hydraulic system with two tanks. (C) 2016, IFAC (International Federation of Automatic Control) Hosting by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1002 / 1007
页数:6
相关论文
共 20 条
  • [1] Supervision of an industrial steam generator. Part I: Bond graph modelling
    Bouamama, BO
    Medjaher, K
    Samantaray, AK
    Staroswiecki, M
    [J]. CONTROL ENGINEERING PRACTICE, 2006, 14 (01) : 71 - 83
  • [2] Breedveld P. C., 1986, INT J MODELING SIMUA, V1, P57
  • [3] Design of unknown input observers and robust fault detection filters
    Chen, J
    Patton, RJ
    Zhang, HY
    [J]. INTERNATIONAL JOURNAL OF CONTROL, 1996, 63 (01) : 85 - 105
  • [4] Chen J, 2012, ROBUST MODEL BASED F
  • [5] Cocquempot V., 2004, 2004 5th Asian Control Conference (IEEE Cat. No.04EX904), P1204
  • [6] Dauphin-Tanguy G., 1999, Simulation Practice and Theory, V7, P493, DOI 10.1016/S0928-4869(99)00009-9
  • [7] Dhouibi H., 2013, IJAREEIE, V2
  • [8] Modular Modeling for the Diagnostic of Complex Discrete-Event Systems
    Gascard, Eric
    Simeu-Abazi, Zineb
    [J]. IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2013, 10 (04) : 1101 - 1123
  • [9] Hashtrudi Zad S., 1999, 38 IEEE C DEC CONTR, P1756
  • [10] Hristov I., 2004, P 5 DAMADICS WORKSH