Ammonia leakage from refrigeration plant and the management practice

被引:48
作者
Gangopadhyay, R. K. [1 ]
Das, S. K. [1 ]
机构
[1] Univ Calcutta, Dept Chem Engn, Kolkata 700009, W Bengal, India
关键词
ammonia; leakage; oil separator; hazard; emergency procedures;
D O I
10.1002/prs.10208
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This article deals with the two incidents of ammonia leakage in industries situated in West Bengal, India, and the probable causes of the accident and the ensuing sequence of events. Emergency procedures are also discussed.
引用
收藏
页码:15 / 20
页数:6
相关论文
共 5 条
[1]  
Fenton DL, 1995, ASHRAE TRAN, V101, P463
[2]  
Henderson Y, 1943, NOXIOUS GASES
[3]  
*NAT I OCC SAF HLT, 1974, NIOSH REC STAND OCC
[4]   Model on-site emergency plan. Case study: Toxic gas release from an ammonia storage terminal [J].
Ramabrahmam, BV ;
Sreenivasulu, B ;
Mallikarjunan, MM .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 1996, 9 (04) :259-265
[5]  
*US EPA, 2001, 550F01009 EPA