Heliostat aiming point optimization for external tower receiver

被引:42
作者
Astolfi, Marco [1 ]
Binotti, Marco [1 ]
Mazzola, Simone [1 ]
Zanellato, Luca [1 ]
Manzolini, Giampaolo [1 ]
机构
[1] Politecn Milan, Grp Energy Convers Syst GECOS, Dipartimento Energia, Via Lambruschini 4, I-20156 Milan, Italy
关键词
Heliostat aiming point; Spillage losses; Yearly optical efficiency; Solar tower plants; FLUX DISTRIBUTION; SOLAR TOWER; DESIGN; FIELD; STRATEGY; SYSTEMS; PLANTS;
D O I
10.1016/j.solener.2016.03.042
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Reduction of peak fluxes on solar receiver is an important research topic because peak minimization can lead to lower receiver temperatures with advantages in terms of thermal efficiency and mechanical stresses. This work proposes different approaches for the minimization of the heat flux on external tower receiver with surround field. The mathematical formulation is implemented in Matlab, while Delsol is used for the heliostat field modeling. Since the number of variables is very high, branching the original optimization problem in a set of sub-problems is a beneficial technique. Four approaches, based on this concept, are here proposed: they differ for the number of field sectors considered in the optimization process and on the heliostat projection modeling. The best approach, which considers the overlapping effect between adjacent sectors, can reduce the peak flux down to 770 kW/m(2) in 120 s of computational time. This value is about 15% lower than reference aiming strategies available in literature. The optimized flux is almost flat in the central part of the receiver while it has significant gradient at the lower and upper border. Finally, a sensitivity analysis shows that the proposed approaches work well at any given solar position and with different heliostat assumptions (i.e. curvature and errors). (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1114 / 1129
页数:16
相关论文
共 34 条
[1]  
Abengoa, 2014, KHI SOL ON
[2]  
[Anonymous], REN 2013 GLOB STAT R
[3]  
[Anonymous], 2014, DELSOL WEB PAGE
[4]  
Augsburger G., 2013, THERMO EC OPTIMISATI
[5]   Modelling of the receiver transient flux distribution due to cloud passages on a solar tower thermal power plant [J].
Augsburger, Germain ;
Favrat, Daniel .
SOLAR ENERGY, 2013, 87 :42-52
[6]   A review of studies on central receiver solar thermal power plants [J].
Behar, Omar ;
Khellaf, Abdallah ;
Mohammedi, Kamal .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 23 :12-39
[7]   Optimal heliostat aiming strategy for uniform distribution of heat flux on the receiver of a solar power tower plant [J].
Besarati, Saeb M. ;
Goswami, D. Yogi ;
Stefanakos, Elias K. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 84 :234-243
[8]   High temperature solar thermal central-receiver billboard design [J].
Boerema, Nicholas ;
Morrison, Graham ;
Taylor, Robert ;
Rosengarten, Gary .
SOLAR ENERGY, 2013, 97 :356-368
[9]   Comparison and Optimization of Heliostat Canting Methods [J].
Buck, R. ;
Teufel, E. .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (01) :0110011-0110018
[10]   A review of optimized design layouts for solar power tower plants with campo code [J].
Collado, Francisco J. ;
Guallar, Jesus .