Heat transfer and friction factor correlations of solar air heater ducts artificially roughened with discrete V-down ribs

被引:219
作者
Singh, Sukhmeet [1 ,2 ]
Chander, Subhash [1 ]
Saini, J. S. [3 ]
机构
[1] Dr BR Ambedkar Natl Inst Technol, Dept Mech Engn, Jalandhar, India
[2] Punjab Agr Univ, Sch Energy Studies Agr, Ludhiana 141004, Punjab, India
[3] Indian Inst Technol, Dept Mech & Ind Engn, Roorkee, Uttar Pradesh, India
关键词
Rib roughness parameters; Relative roughness pitch; Relative gap position; Angle of attack; Relative gap width; LOCAL HEAT/MASS TRANSFER; RECTANGULAR DUCTS; SQUARE CHANNEL; PERFORMANCE; FLOW; BROKEN; TRANSVERSE; PARALLEL;
D O I
10.1016/j.energy.2011.05.052
中图分类号
O414.1 [热力学];
学科分类号
摘要
The heat and fluid flow characteristics of rectangular duct having its one broad wall heated and roughened with periodic 'discrete V-down rib' are experimentally investigated. Reynolds number (Re) has been varied from 3000-15000 with relative gap width (g/e) and relative gap position (d/w) range of 0.5-2.0 and 0.20-0.80 respectively. The respective variation in relative roughness pitch (P/e), angle of attack (alpha) and relative roughness height (e/D-h) have been 4-12, 30 degrees-75 degrees and 0.015-0.043. The effect of roughness parameters on Nusselt number (Nu) and friction factor (f) has been determined and the results obtained were compared with those of smooth duct. The maximum increase in Nu and f over that of smooth duct was 3.04 and 3.11 folds respectively. The rib parameters corresponding to maximum increase in Nu and f were d/w = 0.65, g/e = 1.0, P/e = 8.0, alpha = 60 degrees and e/D-h = 0.043. Correlations for the Nu and f in terms of Re and rib parameters have been developed. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5053 / 5064
页数:12
相关论文
共 33 条
[21]   TURBULENT HEAT-TRANSFER AUGMENTATION AND FRICTION IN PERIODIC FULLY-DEVELOPED CHANNEL FLOWS [J].
LIOU, TM ;
HWANG, JJ .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1992, 114 (01) :56-64
[22]   TURBULENT SHEAR-FLOW AND HEAT-TRANSFER OVER THE REPEATED 2-DIMENSIONAL SQUARE RIBS ON GROUND PLANE [J].
OKAMOTO, S ;
SEO, S ;
NAKASO, K ;
KAWAI, I .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :631-637
[23]   OPTIMAL THERMOHYDRAULIC PERFORMANCE OF ARTIFICIALLY ROUGHENED SOLAR AIR HEATERS [J].
PRASAD, BN ;
SAINI, JS .
SOLAR ENERGY, 1991, 47 (02) :91-96
[24]   HEAT-TRANSFER CHARACTERISTICS OF A SOLAR AIR HEATER USED FOR DRYING PURPOSES [J].
PRASAD, K ;
MULLICK, SC .
APPLIED ENERGY, 1983, 13 (02) :83-93
[25]  
Rohsenow WM., 1998, Handbook of heat transfer, V3
[26]  
Singh S, 2011, J RENEWABLE SUSTAINA, V3
[27]  
Sunden B., 2001, HEAT TRANSFER GAS TU
[28]   Heat transfer in rectangular channels with transverse and V-shaped broken ribs [J].
Tanda, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (02) :229-243
[29]   Experimental heat transfer and friction in channels roughened with angled, V-shaped, and discrete ribs on two opposite walls [J].
Taslim, ME ;
Li, T ;
Kercher, DM .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 1996, 118 (01) :20-28
[30]   An experimental investigation of heat transfer and fluid flow in a rectangular duct with broken V-shaped ribs [J].
Wang, L ;
Sundén, B .