Bicuspid aortic valve surgery with proactive ascending aorta repair

被引:77
作者
Svensson, Lars G. [1 ,2 ]
Kim, Kyung-Hwan [1 ]
Blackstone, Eugene H. [1 ,4 ]
Rajeswaran, Jeevanantham [4 ]
Gillinov, A. Marc [1 ]
Mihaljevic, Tomislav [1 ]
Griffin, Brian P. [3 ]
Grimm, Richard [3 ]
Stewart, William J. [3 ]
Hammer, Donald F. [3 ]
Lytle, Bruce W. [1 ,2 ]
机构
[1] Cleveland Clin, Dept Thorac & Cardiovasc Surg, Inst Heart & Vasc, Cleveland, OH 44195 USA
[2] Cleveland Clin, Aort Surg Ctr, Inst Heart & Vasc, Cleveland, OH 44195 USA
[3] Cleveland Clin, Dept Cardiovasc Med, Inst Heart & Vasc, Cleveland, OH 44195 USA
[4] Cleveland Clin, Res Inst, Dept Quantitat Hlth Sci, Cleveland, OH 44195 USA
关键词
MARFAN-SYNDROME; DISEASE; REIMPLANTATION; REPLACEMENT; INFORMATION; MANAGEMENT; DISSECTION; OPTIONS; RATIO; TIME;
D O I
10.1016/j.jtcvs.2010.10.050
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Bicuspid aortic valves are associated with aortic catastrophes, particularly dissection. We examined whether proactive repair of associated dilatation would reduce risk of subsequent aortic dissection or reoperation and whether more aggressive resection is needed in patients undergoing bicuspid aortic valve surgery alone. Methods: From January 1993 to June 2003, 1989 patients (of our total experience of 4316) underwent bicuspid aortic valve surgery. Long-term outcomes of 1810 were analyzed according to aortic size and whether bicuspid aortic valve surgery was performed alone or with aortic repair. Results: In-hospital 30-day survival was similar (98.8% valve alone vs 98.9% with aortic repair), with no penalty incurred for concomitant aortic repair. Bicuspid aortic valve-alone patients had worse late survival (75% vs 85% at 10 years, P = .0001), but in the matched cohort survival was nearly identical (85% vs 86%; P = .7). With this strategy, freedom from late aortic events was high in both groups (99% valve alone vs 97% with aortic repair at 10 years; P[log-rank] = .06) and similar in the matched cohort (95% vs 97%; P = .2). Approximately 95% of patients undergoing valve-alone surgery had aortic diameters smaller than 4.6 cm or cross-sectional area/height ratios less than 9.4 cm(2)/m; 80% undergoing valve surgery plus aortic repair had diameters larger than 4.1 cm or ratios greater than 7.3 cm(2)/m. Only 0.2% of events occurred at an aortic diameter size of less than 4.5 cm. Conclusions: Aortic size larger than 4.5 cm or aortic cross-sectional area/height ratio greater than 8 to 10 should be considered triggers for concurrent aortic repair, because there is no added risk, and late survival is better; however, more aggressive resection is unwarranted. (J Thorac Cardiovasc Surg 2011;142:622-9)
引用
收藏
页码:622 / U257
页数:11
相关论文
共 26 条
[21]   Sizing for modified David's reimplantation procedure [J].
Svensson, LG .
ANNALS OF THORACIC SURGERY, 2003, 76 (05) :1751-1753
[22]   Surgical options in young adults with aortic valve disease [J].
Svensson, LG ;
Blackstone, EH ;
Cosgrove, DM .
CURRENT PROBLEMS IN CARDIOLOGY, 2003, 28 (07) :417-480
[23]   Aortic cross-sectional area/height ratio timing of aortic surgery in asymptomatic patients with Marfan syndrome [J].
Svensson, LG ;
Khitin, L .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (02) :360-361
[24]   Relationship of aortic cross-sectional area to height ratio and the risk of aortic dissection in patients with bicuspid aortic valves [J].
Svensson, LG ;
Kim, KH ;
Lytle, BW ;
Cosgrove, DM .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (03) :892-893
[25]   Management of aortic valve disease during aortic surgery [J].
Svensson, LG ;
Longoria, J ;
Kimmel, WA ;
Nadolny, E .
ANNALS OF THORACIC SURGERY, 2000, 69 (03) :778-783
[26]   COMPOSITE VALVE GRAFT REPLACEMENT OF THE PROXIMAL AORTA - COMPARISON OF TECHNIQUES IN 348 PATIENTS [J].
SVENSSON, LG ;
CRAWFORD, ES ;
HESS, KR ;
COSELLI, JS ;
SAFI, HJ ;
KOUCHOUKOS, NT ;
COOLEY, DA ;
PASCOE, EA .
ANNALS OF THORACIC SURGERY, 1992, 54 (03) :427-439