Fracture strength of all-ceramic posterior inlay-retained fixed partial dentures

被引:49
作者
Wolfart, Stefan
Ludwig, Klaus
Uphaus, Anja
Kern, Matthias
机构
[1] Sch Dent, Dept Dent Mat, D-24105 Kiel, Germany
[2] Privat Praxis, D-46119 Oberhausen, Germany
[3] Univ Kiel, Sch Dent, Dept Prosthodont Propaedeut & Dent Mat, D-24105 Kiel, Germany
关键词
all-ceramic restoration; FPD; fracture load; zirconia ceramic; YPSZ; glass-ceramic; inlay-retained;
D O I
10.1016/j.dental.2006.12.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The purpose of this in vitro study was to compare the quasi-static (QSFS) and fatigue fracture strength of all-ceramic resin-bonded three unit inlay-retained fixed partial dentures (IRFPDs) made from a heat-pressed lithium-disilicate based glass-ceramic (LDGC) and a CAD/CAM-manufactured yttrium-oxide partially stabilized zirconia framework (YPSZ). Methods. Identical IRFPD-models of the maxilla were used. They consisted of a second premolar, a missing first molar and a second molar (Co-Cr-Mo alloy) integrated in a low melting alloy base. Roots were covered with a soft silicone-layer to simulate an artificial parodontium. Premolars had an occlusal-distal inlay-preparation and molars a mesial-occlusal inlay-preparation. Thirty-two IRFPDs were made from each ceramic using two different connector dimensions: 3 mm x 3 mm (LDGC_9, YPSZ_9); 4 mm x 4 mm (LDGC_16, YPSZ_16). All IRFPDs were cemented adhesively to the IRFPD-models, using composite resin cement. QSFS was tested in a universal-testing-machine (UTM) for six specimens. The other specimens were fatigued either with cyclic loading at 250 N (n = 4) in a chewing simulator or at 600 N (n = 6) using the UTM, and group YPSZ additionally at 1500 N. Results. The medians of QSFS (N) were 960 (LDGC_9), 1316 (LDGC_16), 3180 (YPSZ_9) and 3120 (YPSZ_16). For both QSFS and cyclic loading significant differences were found between LDGC_9 and LDGC_16 (p <= 0.03) but not between YPSZ_9 and YPSZ_16 (p > 0.05). Differences between LDGC and YPSZ were significant for both connector sizes (p <= 0.001). Significance. Considering the maximum chewing forces in the molar region it seems clinically possible, to use YPSZ as a core material for IRFPDs with a connector size between 9 and 16 mm(2). (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1513 / 1520
页数:8
相关论文
共 45 条
[21]   Wear of composite resin veneering materials in a dual-axis chewing simulator [J].
Kern, M ;
Strub, JR ;
Lü, XY .
JOURNAL OF ORAL REHABILITATION, 1999, 26 (05) :372-378
[22]   FRACTURE STRENGTH OF ALL-PORCELAIN, RESIN-BONDED BRIDGES AFTER TESTING IN AN ARTIFICIAL ORAL ENVIRONMENT [J].
KERN, M ;
DOUGLAS, WH ;
FECHTIG, T ;
STRUB, JR ;
DELONG, R .
JOURNAL OF DENTISTRY, 1993, 21 (02) :117-121
[23]  
Kon M, 1990, Dent Mater J, V9, P181
[24]  
Korber K.H., 1983, Dent. Lab, V31, P55
[25]   Influence of design and mode of loading on the fracture strength of all-ceramic resin-bonded fixed partial dentures: An in vitro study in a dual-axis chewing simulator [J].
Koutayas, SO ;
Kern, M ;
Ferraresso, F ;
Stub, JR .
JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (05) :540-547
[26]   ISOMETRIC BITE FORCE AND ITS RELATION TO GENERAL MUSCLE FORGE AND BODY BUILD [J].
LINDERHOLM, H ;
WENNSTROM, A .
ACTA ODONTOLOGICA SCANDINAVICA, 1970, 28 (05) :679-+
[27]  
Nyman S., 2003, CLIN PERIODONTOLOGY, P409
[28]   Influence of connector design on fracture probability of ceramic fixed-partial dentures [J].
Oh, W ;
Götzen, N ;
Anusavice, KJ .
JOURNAL OF DENTAL RESEARCH, 2002, 81 (09) :623-627
[29]  
QUAAS AC, 2006, DENT MAT
[30]   The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: A prospective clinical pilot study [J].
Raigrodski, Ariel J. ;
Chiche, Gerard J. ;
Potiket, Narong ;
Hochstedler, J. L. ;
Mohamed, Shawky E. ;
Billiot, Susan ;
Mercante, Donald E. .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 96 (04) :237-244