Post-earthquake fire resistance of bolted end-plate connection joint with end-plate and web stiffeners

被引:9
作者
Xu, Jixiang [1 ]
Wang, Jianjun [1 ]
Mohamed, Hazem Samih [2 ]
Han, Jianping [1 ]
Han, Zhaolong [3 ]
Tu, Jiahuang [4 ]
Li, Zhanjie [5 ]
机构
[1] Lanzhou Univ Technol, Dept Civil Engn, Lanzhou 730050, Peoples R China
[2] Southwest Petr Univ, Sch Civil Engn & Geomat, Chengdu 610500, Sichuan, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Naval Architecture Ocean & Civil Engn, Shanghai 200240, Peoples R China
[4] Xiangtan Univ, Coll Civil Engn & Mech, Xiangtan 411105, Peoples R China
[5] SUNY Polytech Inst, Dept Engn, Utica, NY 13502 USA
基金
中国国家自然科学基金;
关键词
Extended end-plate connection; Stiffeners; Critical temperature; Post-earthquake fire resistance; COLUMN CONNECTIONS; BEAM; BEHAVIOR;
D O I
10.1016/j.jcsr.2021.106835
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper aims to study the fire resistance of the extended end-plate connection (EEPC) joints under post-earthquake fire (PEF) by considering different earthquake damages, which can reduce the fire resistance of the EEPC-joints. The effectiveness and accuracy of the computation models were verified by using the existing test results. Then, the fire resistance of 8 kinds of the EEPC-joints with different stiffening strategies were compared and analyzed. The results showed that the extended end-plate connection with pentagon end-plate stiffeners and web stiffeners had the best fire resistance and was selected to conduct a parametric analysis under PEF. In order to investigate the effects of different parameters on the fire resistance of the EEPC-joints under PEF, 25 computational models of the extended end-plate connections with pentagon end-plate stiffeners and web stiffeners were established. Then, a parametric study was performed by considering the column flange width-thickness ratio (alpha), beam web height-thickness ratio (beta), ratio of beam end-plate stiffener thickness to beam end-plate thickness (gamma), ratio of the thickness of column web stiffeners to the thickness of the column end-plate (lambda), ratio of the thickness of beam end-plate to column end-plate (xi), the thickness of non-intumescent fire retardant coating and damage variable ((D) over bar). The results showed that damage variables had significant influence on the fire resistance of the EEPC-joints under PEF. The findings of this study can provide the needed reference for fire resistance design of the EEPC-joints under PEF. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:29
相关论文
共 26 条
[1]   Modelling of unstiffened flush end-plate bolted connections in fire [J].
Al-Jabri, KS ;
Seibi, A ;
Karrech, A .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (1-2) :151-159
[2]  
[Anonymous], 2006, CECS200:2006
[3]   Investigations on the fatigue behavior of end plate connections with prestressed bolts [J].
Bartsch, Helen ;
Hoffmeister, Benno ;
Feldmann, Markus .
FATIGUE DESIGN 2019, INTERNATIONAL CONFERENCE ON FATIGUE DESIGN, 8TH EDITION, 2019, 19 :395-404
[4]   Modeling of bolted endplate beam-to-column joints with various stiffeners [J].
Boudia, Sofiane Boumedyen Merad ;
Boumechra, Nadir ;
Bouchair, Abdelhamid ;
Missoum, Abdelghani .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 167
[5]   The response of flush end-plate joints under earthquake loading [J].
Broderick, BM ;
Thomson, AW .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2002, 58 (09) :1161-1175
[6]   Study of stainless steel bolted extended end-plate joints under seismic loading [J].
Bu, Yidu ;
Wang, Yuanqing ;
Zhao, Yipeng .
THIN-WALLED STRUCTURES, 2019, 144
[7]   Experimental assessment of the ductility of extended end plate connections [J].
Coelho, AMG ;
Bijlaard, FSK ;
da Silva, LS .
ENGINEERING STRUCTURES, 2004, 26 (09) :1185-1206
[8]   Structural behaviour of stainless steel beam-to-tubular column joints [J].
Elflah, Mohamed ;
Theofanous, Marios ;
Dirar, Samir ;
Yuan, Huanxin .
ENGINEERING STRUCTURES, 2019, 184 :158-175
[9]   Behavior of extended end-plate bolted connections subjected to monotonic and cyclic loads [J].
ElSabbagh, Ashraf ;
Sharaf, Tarek ;
Nagy, Salah ;
ElGhandour, Mohammed .
ENGINEERING STRUCTURES, 2019, 190 :142-159
[10]   Predicting post-fire mechanical properties of grade 8.8 and 10.9 steel bolts [J].
Ketabdari, Hesamoddin ;
Daryan, Amir Saedi ;
Hassani, Nemat .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 162