Comparison of adenoma detection and miss rates between a novel balloon colonoscope and standard colonoscopy: a randomized tandem study

被引:56
作者
Halpern, Zamir [1 ]
Gross, Seth A. [2 ]
Gralnek, Ian M. [3 ,4 ]
Shpak, Beni [5 ]
Pochapin, Mark [2 ]
Hoffman, Arthur [6 ]
Mizrahi, Meir [7 ]
Rochberger, Yosef S. [5 ]
Moshkowitz, Menachem [5 ]
Santo, Erwin [1 ]
Melhem, Alaa [1 ]
Grinshpon, Roman [1 ]
Pfefer, Jorge [1 ]
Kiesslich, Ralf [6 ]
机构
[1] Tel Aviv Sourasky Med Ctr, IL-64239 Tel Aviv, Israel
[2] NYU, Langone Med Ctr, Div Gastroenterol, New York, NY USA
[3] Rambam Hlth Care Campus, Dept Gastroenterol, Haifa, Israel
[4] Technion Israel Inst Technol, Bruce Rappaport Fac Med, IL-31096 Haifa, Israel
[5] Laniado Hosp, Inst Gastroenterol, Netanya, Israel
[6] St Marienkrankenhaus Frankfurt, Dept Internal Med & Gastroenterol, Frankfurt, Germany
[7] Hadassah Med Ctr, Dept Gastroenterol, IL-91120 Jerusalem, Israel
关键词
SOCIETY TASK-FORCE; COLORECTAL-CANCER; SURVEILLANCE; POLYPECTOMY; MULTICENTER; ENDOSCOPY; INTERVAL; QUALITY; POLYPS;
D O I
10.1055/s-0034-1391437
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims: Although colonoscopy is the "gold standard" for colorectal cancer screening, a significant number of adenomas are still missed during standard colonoscopy, often because they are hidden behind colonic folds and flexures. The aim of this study was to assess the ability of a novel balloon colonoscope (G-EYE endoscope; Smart Medical Systems, Ra'anana, Israel) to increase adenoma detection and reduce the miss rate compared with standard colonoscopy. Patients and methods: This was a multicenter, randomized, prospective, controlled study in patients (age= 40 years) undergoing colonoscopy for screening or diagnostic work-up (including surveillance). Patients underwent same-day, back-to-back tandem colonoscopy. Patients in Group A underwent standard colonoscopy followed by balloon colonoscopy, and patients in Group B underwent balloon colonoscopy followed by the standard technique. The adenoma detection and miss rates were compared between the two colonoscopy procedures. Results: A total of 126 patients were enrolled and randomized into Group A (n=60) or Group B (n= 66). The adenoma miss rate of balloon colonoscopy was significantly lower than that of standard colonoscopy (7.5% vs. 44.7 %; P= 0.0002). The detection of additional adenomas by balloon colonoscopy was significant (81.0 %; P= 0.0002), in particular, the relative amount of adenomas detected in the ascending colon by balloon colonoscopy was 41% versus 14% for standard colonoscopy. Conclusions: A novel balloon colonoscopy technique detected significantly more adenomas than standard colonoscopy, and missed fewer adenomas. Balloon colonoscopy has the potential to increase the effectiveness of colorectal cancer screening and surveillance colonoscopy.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 30 条
[1]   Colonoscopic withdrawal times and adenoma detection during screening colonoscopy [J].
Barclay, Robert L. ;
Vicari, Joseph J. ;
Doughty, Andrea S. ;
Johanson, John F. ;
Greenlaw, Roger L. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (24) :2533-2541
[2]   Association of Colonoscopy and Death From Colorectal Cancer [J].
Baxter, Nancy N. ;
Goldwasser, Meredith A. ;
Paszat, Lawrence F. ;
Saskin, Refik ;
Urbach, David R. ;
Rabeneck, Linda .
ANNALS OF INTERNAL MEDICINE, 2009, 150 (01) :1-W1
[3]   Interval cancers after negative colonoscopy: population-based case-control study [J].
Brenner, Hermann ;
Chang-Claude, Jenny ;
Seiler, Christoph M. ;
Hoffmeister, Michael .
GUT, 2012, 61 (11) :1576-1582
[4]   Colonoscopic miss rates for right-sided colon cancer: A population-based analysis [J].
Bressler, B ;
Paszat, LF ;
Vinden, C ;
Li, C ;
He, JS ;
Rabeneck, L .
GASTROENTEROLOGY, 2004, 127 (02) :452-456
[5]  
Efremidou EI, 2008, CHIRURGIA-BUCHAREST, V103, P659
[6]   Standard forward-viewing colonoscopy versus full-spectrum endoscopy: an international, multicentre, randomised, tandem colonoscopy trial [J].
Gralnek, Ian M. ;
Siersema, Peter D. ;
Halpern, Zamir ;
Segol, Ori ;
Melhem, Alaa ;
Suissa, Alain ;
Santo, Erwin ;
Sloyer, Alan ;
Fenster, Jay ;
Moons, Leon M. G. ;
Dik, Vincent K. ;
D'Agostino, Ralph B., Jr. ;
Rex, Douglas K. .
LANCET ONCOLOGY, 2014, 15 (03) :353-360
[7]   A prospective cohort study evaluating a novel colonoscopy platform featuring full-spectrum endoscopy [J].
Gralnek, Ian Mark ;
Segol, Ori ;
Suissa, Alain ;
Siersema, Peter D. ;
Carr-Locke, David L. ;
Halpern, Zamir ;
Santo, Erwin ;
Domanov, Svetlana .
ENDOSCOPY, 2013, 45 (09) :697-702
[8]   Changing trends in the incidence, stage, survival, and screen-detection of colorectal cancer: A population-based study [J].
Gupta, AK ;
Melton, LJ ;
Petersen, GM ;
Timmons, LJ ;
Vege, SS ;
Harmsen, WS ;
Diehl, NN ;
Zinsmeister, AR ;
Ahlquist, DA .
CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2005, 3 (02) :150-158
[9]   Miss rate for colorectal neoplastic polyps:: a prospective multicenter study of back-to-back video colonoscopies [J].
Heresbach, D. ;
Barrioz, T. ;
Lapalus, M. G. ;
Coumaros, D. ;
Bauret, P. ;
Potier, P. ;
Sautereau, D. ;
Boustiere, C. ;
Grimaud, J. C. ;
Barthelemy, C. ;
See, J. ;
Serraj, I. ;
Halluin, P. N. D. ;
Branger, B. ;
Ponchan, T. .
ENDOSCOPY, 2008, 40 (04) :284-290
[10]   Miss rate of right-sided colon examination during colonoscopy defined by retroflexion: an observational study [J].
Hewett, David G. ;
Rex, Douglas K. .
GASTROINTESTINAL ENDOSCOPY, 2011, 74 (02) :246-252