Non-contact measurement of inter-story drift in three-layer RC structure under seismic vibration using digital image correlation

被引:32
作者
Chang, Ching-Yuan [1 ]
Huang, Chi-Wen [1 ]
机构
[1] Natl Taipei Univ Technol, Dept Mech Engn, Taipei 10617, Taiwan
关键词
Digital image correlation; Health monitoring; Non-contact measurement; Remote inspection; Inter-layer drift; Structural failure; SENSOR PLACEMENT;
D O I
10.1016/j.ymssp.2019.106500
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Earthquakes can cause the unexpected failure of buildings and other structures, and numerous experimental methods have been devised to estimate structural integrity and the likelihood of failure. Unfortunately, the retrofitting of old structures by attaching sensors within walls and columns can be prohibitively expensive, and the analysis of signals obtained from hundreds of devices is time-consuming. In this paper, we introduce a proprietary program based on digital image correlation (DIC) for the measurement of interstory drift in reinforced concrete structures exposed to seismic vibrations. Inter-story drift refers to translational and angular displacement between floors. We applied the proposed DIC program to the measurement of biaxial deformation and probed inter-story drift in a three-layer structure under the effects of seismic waves. Theoretical modeling, experimental measurements, and numerical analysis were used to verify the accuracy of the measured results as well as the structural performance of the deformed structure. Our DIC results are consistent with those obtained using the infra-red motion capture system, linear variable differential transformers, and accelerometers. The proposed DIC metrology enables the simultaneous observation of displacement, acceleration, and drift angle. The ability to perform non-contact inspection and remote measurement makes this scheme applicable to the long-term monitoring of structural performance under seismic vibration. All associated analysis based on frequency spectra using the fast Fourier transform and short-time Fourier transform can be performed using an inexpensive digital camera and a laptop computer, thereby allowing the in-situ monitoring of structural performance under seismic vibration. The experimental setup of the DIC system takes only a few minutes, and the vision-based metrology can track registered patterns from a remote location. Compared with wired sensors, the DIC system provides a more prolonged and safer distance for observing the inter-layer drift of the RC structure under the reproduced TCU052 earthquake. Compared with an OptiTrack system, the DIC system is portable and can cooperate with a universal combination of optical lens, digital camera, and laptop computer. The accuracy and efficiency of the proposed scheme enable the rapid diagnosis of structures affected by earthquakes, while reducing the costs associated with post-earthquake estimates of damage. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:16
相关论文
共 22 条
[1]   Reliability evaluation of predicted structural performances using nonlinear static analysis [J].
Allahvirdizadeh, Reza ;
Gholipour, Yaghoub .
BULLETIN OF EARTHQUAKE ENGINEERING, 2017, 15 (05) :2129-2148
[2]   Implementation of a novel efficient low cost method in structural health monitoring [J].
Asadi, S. ;
Sepehry, N. ;
Shamshirsaz, M. ;
Vaghasloo, Y. A. .
SMART MATERIALS AND STRUCTURES, 2017, 26 (05)
[3]   Increasing the computational efficient of digital cross correlation by a vectorization method [J].
Chang, Ching-Yuan ;
Ma, Chien-Ching .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2017, 92 :293-314
[4]   Experimental validation of cost-effective vision-based structural health monitoring [J].
Feng, Dongming ;
Feng, Maria Q. .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2017, 88 :199-211
[5]   An Embedded Wireless Sensor Network with Wireless Power Transmission Capability for the Structural Health Monitoring of Reinforced Concrete Structures [J].
Gallucci, Luca ;
Menna, Costantino ;
Angrisani, Leopoldo ;
Asprone, Domenico ;
Lo Moriello, Rosario Schiano ;
Bonavolonta, Francesco ;
Fabbrocino, Francesco .
SENSORS, 2017, 17 (11)
[6]   Structural control and health monitoring of building structures with unknown ground excitations: Experimental investigation [J].
He, Jia ;
Xu, You-Lin ;
Zhan, Sheng ;
Huang, Qin .
JOURNAL OF SOUND AND VIBRATION, 2017, 390 :23-38
[7]   Optimal multiaxial sensor placement for modal identification of large structures [J].
He, Longjun ;
Lian, Jijian ;
Ma, Bin ;
Wang, Haijun .
STRUCTURAL CONTROL & HEALTH MONITORING, 2014, 21 (01) :61-79
[8]   Seismic Fragility Assessment of RC Frame-Shear Wall Structures Designed According to the Current Chinese Seismic Design Code [J].
Jiang, Huanjun ;
Liu, Xiaojuan ;
Hu, Lingling .
JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2015, 14 (02) :459-466
[9]   Real-time analysis and interpretation of continuous data from structural health monitoring (SHM) systems [J].
Kaya, Yavuz ;
Safak, Erdal .
BULLETIN OF EARTHQUAKE ENGINEERING, 2015, 13 (03) :917-934
[10]   The impact evaluation of soil liquefaction on low-rise building in the Meinong earthquake [J].
Lu, Chih-Chieh ;
Hwang, Jin-Hung ;
Hsu, Shang-Yi .
EARTH PLANETS AND SPACE, 2017, 69