Comparison of fast swept source full-field OCT with conventional scanning OCT

被引:2
作者
Bonin, Tim [1 ]
Koch, Peter [3 ]
Huettmann, Gereon [1 ,2 ]
机构
[1] Univ Lubeck, Inst Biomed Opt, Peter Monnik Weg 4, D-23562 Lubeck, Germany
[2] Med Laser Ctr Lubeck Germany, D-23562 Lubeck, Germany
[3] Thorlabs HL AG, D-23562 Lubeck, Germany
来源
OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V | 2011年 / 8091卷
关键词
Optical coherence tomography; Lasers (tunable); Three-dimensional image acquisition; Ultrafast measurements; OPTICAL COHERENCE TOMOGRAPHY; HUMAN RETINA;
D O I
10.1117/12.889630
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recently, in-vivo full field (FF) optical coherence tomography (OCT) with an ultra-high speed camera has been presented for fast in vivo retinal imaging. By parallel A-scans acquisition, imaging with 1,5 million A-scans/s was shown with an extended illumination of the retina. In this paper, the image quality of FF-OCT images will be compared to conventional scanning OCT systems. The effect of the absence of a confocal aperture leading to crosstalk between adjacent image points will be shown and an experimental analysis of the systems lateral point spread function (PSF) in dependence of depth will be given and discussed.
引用
收藏
页数:8
相关论文
共 16 条
[1]   Full-field optical coherence microscopy [J].
Beaurepaire, E ;
Boccara, AC ;
Lebec, M ;
Blanchot, L ;
Saint-Jalmes, H .
OPTICS LETTERS, 1998, 23 (04) :244-246
[2]  
BONIN T, 2011, P SPIE, V7889
[3]   In vivo Fourier-domain full-field OCT of the human retina with 1.5 million A-lines/s [J].
Bonin, Tim ;
Franke, Gesa ;
Hagen-Eggert, Martin ;
Koch, Peter ;
Huettmann, Gereon .
OPTICS LETTERS, 2010, 35 (20) :3432-3434
[4]  
CHOMA MA, 2000, APPL OPTICS, V39, P173
[5]   Crosstalk rejection in full-field optical coherence tomography using spatially incoherent illumination with a partially coherent source [J].
Dhalla, Al-Hafeez ;
Migacz, Justin ;
Izatt, Joseph A. .
OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
[6]   Simultaneous topography and tomography of latent fingerprints using full-field swept-source optical coherence tomography [J].
Dubey, Satish Kumar ;
Mehta, Dalip Singh ;
Anand, Arun ;
Shakher, Chandra .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2008, 10 (01)
[7]   Ultrahigh-resolution full-field optical coherence tomography [J].
Dubois, A ;
Grieve, K ;
Moneron, G ;
Lecaque, R ;
Vabre, L ;
Boccara, C .
APPLIED OPTICS, 2004, 43 (14) :2874-2883
[8]   High-resolution full-field optical coherence tomography with a Linnik microscope [J].
Dubois, A ;
Vabre, L ;
Boccara, AC ;
Beaurepaire, E .
APPLIED OPTICS, 2002, 41 (04) :805-812
[9]  
FERGUSSON J, 2010, P SOC PHOTO-OPT INS, V7554, P55401
[10]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332