Study on the prying force of high strength bolt in extended end-plate connection

被引:0
|
作者
Mao, Hui [1 ]
Wang, Yan [2 ]
Zheng, Jie [3 ]
机构
[1] Xian Univ Architecture & Technol, Xian, Shaanxi, Peoples R China
[2] Qingdao Technol Univ, Qingdao, Shandong, Peoples R China
[3] Jining Architectural Design Res Inst, Jining, Shandong, Peoples R China
来源
PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL, SPACE & COMPOSITE STRUCTURES | 2007年
关键词
high strength bolt; finite element; prying force; end-plate connection; T-shaped connection;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this article, ANSYS, a large general FEM software, is selected to carry on stress of mises of the tensile high strength bolt in extended end-plate connection, deformation of end-plate, distribution and change of prying force and tensile force of bolt. Prying force is proved to exist according to the results of FEM analyse. The influence of prying force descends obviously with the thickness of end-plate and the stiffener. It indicates that the prying force increases the tensile force of bolt assuredly. The tensile force distribution of high strength bolt is a trapezoid which is rolled by the center of compression flange. By the result of calculation formula, it indicates that the formula about prying force is simple and applicable for design.
引用
收藏
页码:395 / +
页数:2
相关论文
共 50 条
  • [11] Experimental Investigation of End-Plate Connection with Cruciform Column Section
    Shek, P. N.
    Tahir, M. M.
    Tan, C. S.
    Kueh, A. B. H.
    ADVANCED BUILDING MATERIALS, PTS 1-4, 2011, 250-253 (1-4): : 3730 - 3733
  • [12] Variable-amplitude fatigue behavior of M30 high-strength bolts in end-plate connection joints
    Zhang, Shujia
    Zhou, Zichun
    Wang, Guoqing
    Zhang, Liang
    Ji, Xuanzhe
    Lei, Honggang
    STRUCTURES, 2023, 56
  • [13] Bolt Pre-tension Effect on Performance of Bolted Extended End-plate Moment Connections under Cyclic Loading
    Noferesti H.
    Gerami M.
    International Journal of Engineering, Transactions B: Applications, 2022, 35 (03): : 531 - 543
  • [14] Effect of bolt preloading on rotational stiffness of stainless steel end-plate connections
    Song, Yuchen
    Uya, Brian
    STEEL AND COMPOSITE STRUCTURES, 2023, 48 (05) : 547 - 564
  • [15] Numerical Study on Cyclic Response of End-Plate Biaxial Moment Connection in Box Columns
    Gallegos, Marco
    Nunez, Eduardo
    Herrera, Ricardo
    METALS, 2020, 10 (04)
  • [16] Effect of plate properties on shear strength of bolt group in single plate connection
    Ashakul, Aphinat
    Khampa, Kriangkrai
    STEEL AND COMPOSITE STRUCTURES, 2014, 16 (06) : 611 - 637
  • [17] Experimental study on shear capacity of corrugated steel plate longitudinal seams with ring groove rivet connection and high strength bolt connection
    Su M.
    Zhu C.
    Zhang C.
    Wang M.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (10): : 320 - 331
  • [18] Study on bolt head corrosion influence on the clamping force loss of high strength bolt
    Li, Ming
    Yao, Lingbo
    Zhang, Shuoshuo
    Wang, Dapeng
    He, Zhiqi
    Sun, Guohua
    ENGINEERING FAILURE ANALYSIS, 2021, 129
  • [19] Study of stainless steel bolted extended end-plate joints under seismic loading
    Bu, Yidu
    Wang, Yuanqing
    Zhao, Yipeng
    THIN-WALLED STRUCTURES, 2019, 144
  • [20] Cyclic Response of Sloped Extended End-Plate Moment Connections
    Sun, Guohua
    Li, Zhiqin
    Fang, Youzhen
    Lin, Jun
    Gong, Futao
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (03)