Quantification of PET Myocardial Blood Flow

被引:29
作者
Pelletier-Galarneau, Matthieu [1 ,2 ,3 ]
Martineau, Patrick [1 ,2 ,4 ]
El Fakhri, Georges [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Gordon Ctr Med Imaging, Boston, MA 02114 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Montreal Heart Inst, Dept Med Imaging, Montreal, PQ, Canada
[4] Univ Manitoba, Dept Radiol, Hlth Sci Ctr, Winnipeg, MB, Canada
关键词
Positron emission tomography; Myocardial blood flow; Myocardial flow reserve; Coronary artery disease; Myocardial perfusion imaging; POSITRON-EMISSION-TOMOGRAPHY; CORONARY-ARTERY-DISEASE; CARDIAC ALLOGRAFT VASCULOPATHY; RESERVE-GUIDED PCI; PERFUSION RESERVE; PROGNOSTIC VALUE; COMPUTED-TOMOGRAPHY; MICROVASCULAR DYSFUNCTION; DIAGNOSTIC PERFORMANCE; VASCULAR DYSFUNCTION;
D O I
10.1007/s11886-019-1096-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose of ReviewThe aim of this review is to provide an update on quantification of myocardial blood flow (MBF) with positron emission tomography (PET) imaging. Technical and clinical aspects of flow quantification with PET are reviewed.Recent FindingsThe diagnostic and prognostic values of myocardial flow quantification have been established in numerous studies and in various populations. MBF quantification has also shown itself to be particularly useful in the assessment of coronary microvascular dysfunction and in evaluation of cardiac allograft vasculopathy. Overall, myocardial flow reserve (MFR) and hyperemic MBF can lead to improved risk stratification by providing information complementary to that of other markers of disease severity, such as fractional flow reserve.SummaryFlow quantification enhances MPI's ability to detect both significant epicardial disease and microvascular dysfunction. With recent technological and methodological advances, flow quantification with PET is no longer restricted to cyclotron-equipped academic centers.
引用
收藏
页数:10
相关论文
共 76 条
[1]   Relationship between coronary function by positron emission tomography and temporal changes in morphology by intravascular ultrasound (IVUS) in transplant recipients [J].
Allen-Auerbach, M ;
Schöder, H ;
Johnson, J ;
Kofoed, K ;
Einhorn, K ;
Phelps, ME ;
Kobashigawa, J ;
Czernin, J .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 1999, 18 (03) :211-219
[2]   Single-scan rest/stress imaging 18F-labeled flow tracers [J].
Alpert, Nathaniel ;
Fang, Yu-Hua Dean ;
El Fakhri, Georges .
MEDICAL PHYSICS, 2012, 39 (11) :6609-6620
[3]  
[Anonymous], 2016, RUBY FILL RUB RB82 G
[4]   Myocardial Blood Flow and Fibrosis in Hypertrophic Cardiomyopathy [J].
Aquaro, Giovanni Donato ;
Todiere, Giancarlo ;
Barison, Andrea ;
Strata, Elisabetta ;
Marzilli, Mario ;
Pingitore, Alessandro ;
Lombardi, Massimo .
JOURNAL OF CARDIAC FAILURE, 2011, 17 (05) :384-391
[5]   DETERMINATION OF CORONARY FLOW EQUIVALENT WITH COINCIDENCE COUNTING TECHNIC [J].
BING, RJ ;
BLUEMCHE.G ;
GALLAGHER, JP ;
ZALESKI, EJ ;
BENNISH, A ;
COHEN, A .
CIRCULATION, 1964, 29 (06) :833-&
[6]  
Burrell S, 2006, J NUCL MED TECHNOL, V34, P193
[7]   PET Assessment of Epicardial Intimal Disease and Microvascular Dysfunction in Cardiac Allograft Vasculopathy [J].
Chih, Sharon ;
Chong, Aun Yeong ;
Erthal, Fernanda ;
deKemp, Robert A. ;
Davies, Ross A. ;
Stadnick, Ellamae ;
So, Derek Y. ;
Overgaard, Christopher ;
Wells, George ;
Mielniczuk, Lisa M. ;
Beanlands, Rob S. B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (13) :1444-1456
[8]   INFLUENCE OF AGE AND HEMODYNAMICS ON MYOCARDIAL BLOOD-FLOW AND FLOW RESERVE [J].
CZERNIN, J ;
MULLER, P ;
CHAN, S ;
BRUNKEN, RC ;
PORENTA, G ;
KRIVOKAPICH, J ;
CHEN, KW ;
CHAN, A ;
PHELPS, ME ;
SCHELBERT, HR .
CIRCULATION, 1993, 88 (01) :62-69
[9]   Quantitative Assessment of Myocardial Perfusion in the Detection of Significant Coronary Artery Disease Cutoff Values and Diagnostic Accuracy of Quantitative [15O]H2O PET Imaging [J].
Danad, Ibrahim ;
Uusitalo, Valtteri ;
Kero, Tanja ;
Saraste, Antti ;
Raijmakers, Pieter G. ;
Lammertsma, Adriaan A. ;
Heymans, Martijn W. ;
Kajander, Sami A. ;
Pietilae, Mikko ;
James, Stefan ;
Soerensen, Jens ;
Knaapen, Paul ;
Knuuti, Juhani .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (14) :1464-1475
[10]   Impact of anatomical and functional severity of coronary atherosclerotic plaques on the transmural perfusion gradient: a [15O]H2O PET study [J].
Danad, Ibrahim ;
Raijmakers, Pieter G. ;
Harms, Hendrik J. ;
Heymans, Martijn W. ;
van Royen, Niels ;
Lubberink, Mark ;
Boellaard, Ronald ;
van Rossum, Albert C. ;
Lammertsma, Adriaan A. ;
Knaapen, Paul .