Carbon ceramic microelectrodes modified with buckyballs for simultaneous determination of redox-active biomolecules

被引:8
作者
Shastan, Z. Omara [1 ]
Ganesh, Hashwin V. S. [2 ]
Noroozifar, Meissam [1 ]
Kerman, Kagan [2 ]
机构
[1] Univ Sistan & Baluchestan, Dept Chem, POB 98135-674, Zahedan, Iran
[2] Univ Toronto Scarborough, Dept Phys & Environm Sci, 1265 Mil Trail, Toronto, ON M1C 1A4, Canada
来源
RSC ADVANCES | 2018年 / 8卷 / 11期
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
ASCORBIC-ACID; URIC-ACID; MODIFIED ELECTRODE; SENSITIVE DETERMINATION; SELECTIVE DETECTION; GOLD NANOPARTICLES; PASTE ELECTRODE; DOPAMINE; GRAPHENE; TRYPTOPHAN;
D O I
10.1039/c7ra09603h
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this report, simultaneous electrochemical determination of ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp) was achieved using buckyball-modified carbon ceramic microelectrodes (CCMEs). A concentration-dependent increase in anodic peak current signals was observed in comparison with those obtained at bare CCMEs. The optimal pH for simultaneous determination of a quaternary mixture of AA-DA-UA-Trp was determined to be pH 4. The peak separations for the mixture containing AA-DA-UA-Trp were well-defined at the scan rate of 50 mV s(-1). The catalytic peak current obtained was linearly dependent on the AA, DA, UA and Trp concentrations in the range of 6.0600, 6.0-600, 6.0-600 and 4.0-440 mu M, respectively. The detection limits for AA, DA, UA and Trp were also determined to be 1.64, 0.82, 0.36 and 1.22 mu M, respectively. The analytical performance of this sensor has also been challenged for simultaneous electrochemical detection of AA, DA, UA and Trp in real samples.
引用
收藏
页码:5960 / 5966
页数:7
相关论文
共 44 条
  • [1] Method for Preparation of a Sol-Gel-Derived Carbon Ceramic Electrode Using Microwave Irradiation
    Abbaspour, Abdolkarim
    Ghaffarinejad, Ali
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (09) : 3660 - 3664
  • [2] Aravind S.S.J., 2012, Nanosci. Methods, V1, DOI [DOI 10.1080/17458080.2010.520136, 10.1080/17458080.2010.520136]
  • [3] Poly(3,4-ethylenedioxythiophene-co-(5-amino-2-naphthalenesulfonic acid)) (PEDOT-PANS) film modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid and uric acid
    Balamurugan, A.
    Chen, Shen-Ming
    [J]. ANALYTICA CHIMICA ACTA, 2007, 596 (01) : 92 - 98
  • [4] Organocatalytic reactions: effects of ball milling, microwave and ultrasound irradiation
    Bruckmann, Angelika
    Krebs, Anke
    Bolm, Carsten
    [J]. GREEN CHEMISTRY, 2008, 10 (11) : 1131 - 1141
  • [5] Active nano-CuPt3 electrocatalyst supported on graphene for enhancing reactions at the cathode in all-vanadium redox flow batteries
    Flox, Cristina
    Rubio-Garcia, Javier
    Nafria, Raquel
    Zamani, Reza
    Skoumal, Marcel
    Andreu, Teresa
    Arbiol, Jordi
    Cabot, Andreu
    Ramon Morante, Joan
    [J]. CARBON, 2012, 50 (06) : 2372 - 2374
  • [6] Microwave-assisted polymer synthesis: Recent developments in a rapidly expanding field of research
    Hoogenboom, Richard
    Schubert, Ulrich S.
    [J]. MACROMOLECULAR RAPID COMMUNICATIONS, 2007, 28 (04) : 368 - 386
  • [7] Sensitive Determination of Dopamine and Uric Acid by the Use of a Glassy Carbon Electrode Modified with Poly(3-methylthiophene)/Gold Nanoparticle Composites
    Huang, Xue
    Li, Yongxin
    Wang, Po
    Wang, Lun
    [J]. ANALYTICAL SCIENCES, 2008, 24 (12) : 1563 - 1568
  • [8] Simultaneous and sensitive determination of ascorbic acid, dopamine, uric acid, and tryptophan with silver nanoparticles-decorated reduced graphene oxide modified electrode
    Kaur, Balwinder
    Pandiyan, Thangarasu
    Satpati, Biswarup
    Srivastava, Rajendra
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 111 : 97 - 106
  • [9] Khalid Iqbal Khalid Iqbal, 2004, Pakistan Journal of Nutrition, V3, P5
  • [10] Exploration of synergism between a polymer matrix and gold nanoparticles for selective determination of dopamine
    Kumar, SS
    Mathiyarasu, J
    Phani, KL
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 578 (01) : 95 - 103