Simple modification of arm position improves B1+ and signal homogeneity in the thoracolumbar spine at 3T

被引:2
作者
Ishizaka, Kinya [1 ]
Kudo, Kohsuke [2 ]
Harada, Kuniaki [3 ]
Shirai, Toru [4 ]
Fujiwara, Taro [1 ]
Aoike, Suzuko [1 ]
Takamori, Sayaka [1 ]
Shirato, Hiroki [5 ,6 ]
机构
[1] Hokkaido Univ Hosp, Dept Radiol Technol, Sapporo, Hokkaido, Japan
[2] Hokkaido Univ Hosp, Div Diagnost & Intervent Radiol, Sapporo, Hokkaido, Japan
[3] Hitachi Ltd, Healthcare Business Unit, Tokyo, Japan
[4] Hitachi Ltd, Res & Dev Grp, Tokyo, Japan
[5] Hokkaido Univ, Grad Sch Med, Dept Radiat Med, Sapporo, Hokkaido, Japan
[6] Hokkaido Univ, Global Stn Quantum Med Sci & Engn, Global Inst Collaborat Res & Educ, Sapporo, Hokkaido, Japan
关键词
thoracolumbar spine MRI; arms position; B-1(+) homogeneity; 3.0; T; MRI; EXCITATION; FIELD; ARTIFACTS; ARRAY; PADS; CORD;
D O I
10.1002/jmri.25767
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo evaluate the homogeneity of the radiofrequency magnetic field (B-1(+)) and signal intensity using different arm positions during 3T thoracolumbar spinal imaging. Materials and MethodsTwenty volunteers were scanned with a four-channel radiofrequency (RF) transmit coil at 3T, with arms on the bed (conventional), arms elevated by 100 mm (arm lift), or with the arms-up position (elevated arm). Axial B-1(+) maps and sagittal T-1-weighted image (T1WI)-performed RF shimming were obtained for each arm position. The mean and standard deviation (SD) of the flip angle (FA) at the center of the vertebra on each B-1(+) map, and contrast noise ratios (CNRs) between the spinal cord and cerebrospinal fluid of sagittal T1WI, were calculated and compared among the different arm positions. ResultsMean FA values (degrees) for the arm lift and elevated arm positions were significantly larger than for the conventional position (P < 0.001 for both) at the twelfth thoracic vertebra (Th12). FA SD values for the arm lift and elevated arm position were significantly smaller than for the conventional position (P < 0.001 for both) at Th12. CNR for the arm lift and elevated arm position were significantly higher than for the conventional position (P = 0.007 and 0.002, respectively). The mean and SD of the FA and the CNR did not differ significantly for the arm lift and elevated arm positions (P = 0.591, 0.958, and 0.927, respectively). ConclusionInhomogeneities of B-1(+) and signal intensities were improved by simply changing the arm position in 3T thoracolumbar spinal imaging. Level of Evidence: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:123-130.
引用
收藏
页码:123 / 130
页数:8
相关论文
共 25 条
  • [1] 3 T MRI: Advances in brain imaging
    Alvarez-Linera, Juan
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2008, 67 (03) : 415 - 426
  • [2] Imaging artifacts at 3.OT
    Bernstein, Matt A.
    Huston, John, III
    Ward, Heidi A.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (04) : 735 - 746
  • [3] Evaluation of dual-source parallel RF excitation technology in MRI of thoraco-lumbar spine at 3.0T
    Bouvier, J.
    Tropres, I.
    Lamalle, L.
    Grand, S.
    Breil, S.
    Le Bas, J. -F.
    Krainik, A.
    [J]. JOURNAL OF NEURORADIOLOGY, 2013, 40 (02) : 94 - 100
  • [4] High Permittivity Pads Reduce Specific Absorption Rate, Improve B1 Homogeneity, and Increase Contrast-to-Noise Ratio for Functional Cardiac MRI at 3 T
    Brink, Wyger M.
    Webb, Andrew G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) : 1632 - 1640
  • [5] Intervertebral Disc Internal Deformation Measured by Displacements Under Applied Loading with MRI at 3T
    Chan, Deva D.
    Neu, Corey P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1231 - 1237
  • [6] Increasing signal homogeneity and image quality in abdominal imaging at 3 T with very high permittivity materials
    de Heer, P.
    Brink, W. M.
    Kooij, B. J.
    Webb, A. G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (04) : 1317 - 1324
  • [7] Artifacts in 3-T MRI: Physical background and reduction strategies
    Dietrich, Olaf
    Reiser, Maximilian F.
    Schoenberg, Stefan O.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (01) : 29 - 35
  • [8] COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING
    GLOVER, GH
    HAYES, CE
    PELC, NJ
    EDELSTEIN, WA
    MUELLER, OM
    HART, HR
    HARDY, CJ
    ODONNELL, M
    BARBER, WD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) : 255 - 270
  • [9] Local SAR management by RF Shimming: a simulation study with multiple human body models
    Homann, Hanno
    Graesslin, Ingmar
    Eggers, Holger
    Nehrke, Kay
    Vernickel, Peter
    Katscher, Ulrich
    Doessel, Olaf
    Boernert, Peter
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2012, 25 (03) : 193 - 204
  • [10] Ito K, 2013, P 21 ANN M ISMRM SAL