Adsorption of IgG on/in a PAH/PSS multilayer film: Layer structure and cell response

被引:22
作者
Feldoto, Zsombor [1 ]
Lundin, Maria [1 ]
Braesch-Andersen, Sten [3 ]
Blomberg, Eva [1 ,2 ]
机构
[1] Royal Inst Technol, Sch Chem Sci & Engn, Dept Chem, SE-10044 Stockholm, Sweden
[2] Inst Surface Chem, SE-11486 Stockholm, Sweden
[3] Mabtech AB, SE-13128 Nacka, Sweden
关键词
PAH; PSS; Polyelectrolyte multilayer; Layer-by-layer deposition; IgG; Incorporation; Adsorption; QCM; DPI; ELISpot; Cytokine; Cell response; QUARTZ-CRYSTAL MICROBALANCE; ANTIBODY-SECRETING CELLS; ATOMIC-FORCE MICROSCOPY; POLYELECTROLYTE MULTILAYERS; GROWTH REGIME; INTERNAL STRUCTURE; ELLIPSOMETRY; POLYSTYRENE; SURFACES; BUILDUP;
D O I
10.1016/j.jcis.2010.10.006
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The binding of immunogloblulins (IgG) (mouse monoclonal recognizing IFN gamma) on precoated polystyrene or silica surfaces by the layer-by-layer technique has been investigated with QCM-D and DPI. The aim of the work was to increase the sensitivity of the conventional enzyme-linked immunosorbent spot (ELISpot) assay. The polyelectrolytes used to build the multilayers were poly(allylamine hydrochloride) (PAH)/poly(sodium 4-styrenesulfonate) (PSS) alternately adsorbed from 150 mM NaCl. The multilayer build up is linear and the internal structure of the PAH/PSS multilayer is compact and rigid as observed by low relative water content (20-25%) and high layer refractive index (n similar to 1.5) after the formation of five bilayers. Incorporation of IgG within the PAH/PSS multilayer did not give rise to overcharging and did not affect the linear build up. ELISpot test on PAH/PSS multilayer modified polystyrene wells showed that the cytokine response was significantly smaller than on the regular PVDF backed polystyrene wells. This may be due to the compact and rigid nature of the PAH/PSS multilayer, which does not allow formation of the kind of three dimensional support needed to achieve bioactive IgG binding to the surface. Immunological tests of the polyelectrolyte multilayers in the absence of IgG showed that PSS terminated PAH/PSS multilayer did not induce any cytokine response whereas PAH terminated did, which suggests that PSS totally covers the surface from the cells point of view. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 55 条
[1]   Direct determination of the thermodynamics of polyelectrolyte complexation and implications thereof for electrostatic layer-by-layer assembly of multilayer films [J].
Bharadwaj, Satish ;
Montazeri, Reza ;
Haynie, Donald T. .
LANGMUIR, 2006, 22 (14) :6093-6101
[2]   Surface interactions during polyelectrolyte multilayer buildup. 1. Interactions and layer structure in dilute electrolyte solutions [J].
Blomberg, E ;
Poptoshev, E ;
Claesson, PM ;
Caruso, F .
LANGMUIR, 2004, 20 (13) :5432-5438
[3]   Probing BSA binding to citrate-coated gold nanoparticles and surfaces [J].
Brewer, SH ;
Glomm, WR ;
Johnson, MC ;
Knag, MK ;
Franzen, S .
LANGMUIR, 2005, 21 (20) :9303-9307
[4]   Ideal mixing in polyelectrolyte complexes and multilayers: Entropy driven assembly [J].
Bucur, Claudiu B. ;
Sui, Zhijie ;
Schlenoff, Joseph B. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (42) :13690-13691
[5]  
Butler J. E., 1993, Molecular Immunology, V30, P1165, DOI 10.1016/0161-5890(93)90135-X
[6]   THE PHYSICAL AND FUNCTIONAL-BEHAVIOR OF CAPTURE ANTIBODIES ADSORBED ON POLYSTYRENE [J].
BUTLER, JE ;
NI, L ;
NESSLER, R ;
JOSHI, KS ;
SUTER, M ;
ROSENBERG, B ;
CHANG, J ;
BROWN, WR ;
CANTARERO, LA .
JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 150 (1-2) :77-90
[7]  
Caruso F, 2000, CHEM-EUR J, V6, P413, DOI 10.1002/(SICI)1521-3765(20000204)6:3<413::AID-CHEM413>3.0.CO
[8]  
2-9
[9]   Characterization of polyelectrolyte-protein multilayer films by atomic force microscopy, scanning electron microscopy, and Fourier transform infrared reflection-absorption spectroscopy [J].
Caruso, F ;
Furlong, DN ;
Ariga, K ;
Ichinose, I ;
Kunitake, T .
LANGMUIR, 1998, 14 (16) :4559-4565
[10]   Assembly of alternating polyelectrolyte and protein multilayer films for immunosensing .2. [J].
Caruso, F ;
Niikura, K ;
Furlong, DN ;
Okahata, Y .
LANGMUIR, 1997, 13 (13) :3427-3433