Layout and first XRF applications of the BAMline at BESSY II

被引:98
作者
Riesemeier, H
Ecker, K
Görner, W
Müller, BR
Radtke, M
Krumrey, M
机构
[1] Bundesanstalt Mat Forsch & Prufung, D-12200 Berlin, Germany
[2] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
D O I
10.1002/xrs.750
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The first hard x-ray beamline at BESSY II has been installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a double-multilayer monochromator and a double-crystal monochromator. Depending on the application, the two devices are used separately or in-line. The main applications of the monochromatic radiation with photon energies up to 60 keV are x-ray fluorescence analysis, micro computed tomography, x-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV is available for radiometric applications. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:160 / 163
页数:4
相关论文
共 10 条
[1]   Aluminum impurities in silicon: Investigation of x-ray Raman scattering in total reflection x-ray fluorescence spectroscopy [J].
Baur, K ;
Kerner, J ;
Brennan, S ;
Singh, A ;
Pianetta, P .
JOURNAL OF APPLIED PHYSICS, 2000, 88 (08) :4642-4647
[2]   X-ray detector calibration in the PTB radiometry laboratory at the electron storage ring BESSY II [J].
Beckhoff, B ;
Klein, R ;
Krumrey, M ;
Scholze, F ;
Thornagel, R ;
Ulm, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) :480-483
[3]  
BORIKOV VM, 1998, J SYNCHROTRON RADIAT, V5, P440
[4]   RBS, SY-XRF, INAA and ICP-IDMS of antimony implanted in silicon -: A multi-method approach to characterize and certify a reference material [J].
Ecker, KH ;
Wätjen, U ;
Berger, A ;
Persson, L ;
Pritzkow, W ;
Radtke, M ;
Riesemeier, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 188 :120-125
[5]   HIGH-PRECISION SOFT-X-RAY REFLECTOMETER [J].
FUCHS, D ;
KRUMREY, M ;
MULLER, P ;
SCHOLZE, F ;
ULM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :2248-2250
[6]  
Hentschel MP, 1999, AIP CONF PROC, V497, P655, DOI 10.1063/1.1302070
[7]  
KRUMERY M, NUCL INSTRUM METHODS
[8]   Measurement and calculation of the spatial and spectral distribution of wavelength shifter radiation at BESSY [J].
Thornagel, R ;
Fliegauf, R ;
Klein, R ;
Scholze, F ;
Ulm, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03) :653-657
[9]  
WEIDEMANN G, 2000, UNPUB P MICROMAT 200
[10]   Determination of the β- branching ratio of 64Cu by mass spectrometric in vestigations of the decay products in neutron transmuted copper [J].
Wermann, G ;
Alber, D ;
Pritzkow, W ;
Riebe, G ;
Vogl, J ;
Görner, W .
APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) :145-151