Fixation, registration, and image-guided navigation using a thermoplastic facial mask in electromagnetic navigation-guided radiofrequency thermocoagulation

被引:7
作者
Chen, Min-jie [1 ]
Gu, Li-xu [2 ]
Zhang, Wei-jie [1 ]
Yang, Chi [1 ]
Zhao, Jing [2 ]
Shao, Zi-yang [1 ]
Wang, Bao-li [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Oral & Maxillofacial Surg, Peoples Hosp 9, Shanghai Key Lab Stomatol,Sch Med, Shanghai 200011, Peoples R China
[2] Shanghai Jiao Tong Univ, Med X Res Inst, Shanghai 200011, Peoples R China
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2010年 / 110卷 / 04期
关键词
INTRACTABLE TRIGEMINAL NEURALGIA; HEAD FIXATION; RHIZOTOMY; IMMOBILIZATION; NEUROSURGERY; RADIOTHERAPY; EXPERIENCE; ACCURACY; SYSTEMS;
D O I
10.1016/j.tripleo.2010.04.040
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. For fixation, registration, and image-guided navigation, the aim of this study was to evaluate a thermoplastic facial mask with plastic markers in achieving frameless stereotactic radiofrequency thermocoagulation (RFT). Study design. A thermoplastic facial mask was remolded according to each subject's face. Six markers were placed on the surface and 6 inside. Series of 1.25-mm- and 2.5-mm- slice computerized tomography (CT) scans were made to provide radiologic data. During the phantom study, each plastic sphere inside was selected in turn as the target for frameless stereotaxy. The clinical Hartel puncture of the foramen ovale (FO) was imitated using an electromagnetic navigation system. Navigation-guided RFT was tried in 3 patients. Results. The mean location error was 1.29 mm (SD +/- 0.39 mm). No significant difference (P > .05) was proven between 1.25-mm and 2.5-mm CT slice acquisition for the image datasets used. The FO punctures in clinical trials were successful and confirmed by CT. Conclusions. Registration and fixation via a fiducial marker-based thermoplastic facial mask is accurate and feasible for use in navigation-guided RFT. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e43-e48)
引用
收藏
页码:E43 / E48
页数:6
相关论文
共 23 条
  • [1] Frameless stereotactic cannulation of the foramen ovale for ablative treatment of trigeminal neuralgia
    Bale, Reto J.
    Laimer, Ilse
    Martin, Arno
    Schlager, Andreas
    Mayr, Christoph
    Rieger, Michael
    Czermak, Benedikt V.
    Kovacs, Peter
    Widmann, Gerlig
    [J]. NEUROSURGERY, 2006, 59 (04) : 394 - 401
  • [2] Minimally invasive head holder to improve the performance of frameless stereotactic surgery
    Bale, RJ
    Vogele, M
    Freysinger, W
    Gunkel, AR
    Martin, A
    Bumm, K
    Thumfart, WF
    [J]. LARYNGOSCOPE, 1997, 107 (03) : 373 - 377
  • [3] Computer-assisted neurosurgery by using a noninvasive vacuum-affixed dental cast that acts as a reference base: another step toward a unified approach in the treatment of brain tumors
    Bale, RJ
    Burtscher, J
    Eisner, W
    Obwegeser, AA
    Rieger, M
    Sweeney, RA
    Dessl, A
    Giacomuzzi, SM
    Twerdy, K
    Jaschke, W
    [J]. JOURNAL OF NEUROSURGERY, 2000, 93 (02) : 208 - 213
  • [4] Comparison of two dead and neck immobilization systems
    Bentel, GC
    Marks, LB
    Hendren, K
    Brizel, DM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (04): : 867 - 873
  • [5] A NEW MODEL FOR NONINVASIVE, REPRODUCIBLE FIXATION OF A STEREOTAXIC FRAME USING AN ORTHODONTIC RESIN PLATE
    CARINI, S
    CALCAGNO, E
    TORTORIDONATI, P
    ANDREUSSI, L
    [J]. ACTA NEUROCHIRURGICA, 1992, 118 (3-4) : 159 - 161
  • [6] Accuracy of true frameless stereotaxy: in vivo measurement and laboratory phantom studies - Technical note
    Dorward, NL
    Alberti, O
    Palmer, JD
    Kitchen, ND
    Thomas, DGT
    [J]. JOURNAL OF NEUROSURGERY, 1999, 90 (01) : 160 - 168
  • [7] Predicting error in rigid-body point-based registration
    Fitzpatrick, JM
    West, JB
    Maurer, CR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 694 - 702
  • [8] Is mask-based stereotactic head-and-neck fixation as precise as stereotactic head fixation for precision radiotherapy?
    Georg, Dietmar
    Bogner, Joachim
    Dieckmann, Karin
    Potter, Richard
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (04): : S61 - S66
  • [9] Repositioning accuracy of a noninvasive head fixation system for stereotactic radiotherapy
    Hamilton, RJ
    Kuchnir, FT
    Pelizzari, CA
    Sweeney, PJ
    Rubin, SJ
    [J]. MEDICAL PHYSICS, 1996, 23 (11) : 1909 - 1917
  • [10] Hartel F, 1912, Langenbecks Arch Klin Chir, V100, P16