Novel electrochemical sensor system for protein using the aptamers in sandwich manner

被引:225
作者
Ikebukuro, K [1 ]
Kiyohara, C [1 ]
Sode, K [1 ]
机构
[1] Tokyo Univ Agr & Technol, Dept Life & Biotechnol, Koganei, Tokyo 1848588, Japan
关键词
aptamer; sandwich manner; electrochemical detection; pyrroquinoline quinone glucose dehydrogenase ((PQQ)GDH);
D O I
10.1016/j.bios.2004.09.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Novel electrochemical detection system for protein in sandwich manner using the aptamers was developed. Two different aptamers, which recognize different positions of thrombin, were chosen to construct sandwich type sensing system for protein, and one was immobilized onto the gold electrode for capturing thrombin onto the electrode and the other was used for detection. To obtain the signal, the aptamer for detection was labeled with pyrroquinoline quinone glucose dehydrogenase ((PQQ)GDH), and the electrical current, generated from glucose addition after the formation of the complex of thrombin, gold immobilized aptamer and the (PQQ)GDH labeled aptamer on the electrode, was measured. The increase of the electric current generated by (PQQ)GDH was observed in dependent manner of the concentration of thrombin added, and more than 10 nM thrombin was detected selectively. The batch type protein sensing system was constructed using the two different aptamers sandwiching thrombin and it showed linear response to the increase of the thrombin concentration in the range of 40-100 nM. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:2168 / 2172
页数:5
相关论文
共 17 条
  • [11] Aptamer-based biosensor arrays for detection and quantification of biological macromolecules
    McCauley, TG
    Hamaguchi, N
    Stanton, M
    [J]. ANALYTICAL BIOCHEMISTRY, 2003, 319 (02) : 244 - 250
  • [12] An improved method for the in vitro evolution of aptamers and applications in protein detection and purification -: art. no. e110
    Murphy, MB
    Fuller, ST
    Richardson, PM
    Doyle, SA
    [J]. NUCLEIC ACIDS RESEARCH, 2003, 31 (18) : e110
  • [13] Adapting selected nucleic acid ligands (aptamers) to biosensors
    Potyrailo, RA
    Conrad, RC
    Ellington, AD
    Hieftje, GM
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (16) : 3419 - 3425
  • [14] SODE K, 2000, ENZ MICROBIOL TECHNO, V26, P820
  • [15] Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing
    Tang, ZP
    Louie, RF
    Lee, JH
    Lee, DM
    Miller, EE
    Kost, GJ
    [J]. CRITICAL CARE MEDICINE, 2001, 29 (05) : 1062 - 1070
  • [16] Oligonucleotide inhibitors of human thrombin that bind distinct epitopes
    Tasset, DM
    Kubik, MF
    Steiner, W
    [J]. JOURNAL OF MOLECULAR BIOLOGY, 1997, 272 (05) : 688 - 698
  • [17] SYSTEMATIC EVOLUTION OF LIGANDS BY EXPONENTIAL ENRICHMENT - RNA LIGANDS TO BACTERIOPHAGE-T4 DNA-POLYMERASE
    TUERK, C
    GOLD, L
    [J]. SCIENCE, 1990, 249 (4968) : 505 - 510