Novel electrochemical sensor system for protein using the aptamers in sandwich manner

被引:225
作者
Ikebukuro, K [1 ]
Kiyohara, C [1 ]
Sode, K [1 ]
机构
[1] Tokyo Univ Agr & Technol, Dept Life & Biotechnol, Koganei, Tokyo 1848588, Japan
关键词
aptamer; sandwich manner; electrochemical detection; pyrroquinoline quinone glucose dehydrogenase ((PQQ)GDH);
D O I
10.1016/j.bios.2004.09.002
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Novel electrochemical detection system for protein in sandwich manner using the aptamers was developed. Two different aptamers, which recognize different positions of thrombin, were chosen to construct sandwich type sensing system for protein, and one was immobilized onto the gold electrode for capturing thrombin onto the electrode and the other was used for detection. To obtain the signal, the aptamer for detection was labeled with pyrroquinoline quinone glucose dehydrogenase ((PQQ)GDH), and the electrical current, generated from glucose addition after the formation of the complex of thrombin, gold immobilized aptamer and the (PQQ)GDH labeled aptamer on the electrode, was measured. The increase of the electric current generated by (PQQ)GDH was observed in dependent manner of the concentration of thrombin added, and more than 10 nM thrombin was detected selectively. The batch type protein sensing system was constructed using the two different aptamers sandwiching thrombin and it showed linear response to the increase of the thrombin concentration in the range of 40-100 nM. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:2168 / 2172
页数:5
相关论文
共 17 条
  • [1] Specific oligobodies against ERK-2 that recognize both the native and the denatured state of the protein
    Bianchini, M
    Radrizzani, M
    Brocardo, MG
    Reyes, GB
    Solveyra, CG
    Santa-Coloma, TA
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2001, 252 (1-2) : 191 - 197
  • [2] SELECTION OF SINGLE-STRANDED-DNA MOLECULES THAT BIND AND INHIBIT HUMAN THROMBIN
    BOCK, LC
    GRIFFIN, LC
    LATHAM, JA
    VERMAAS, EH
    TOOLE, JJ
    [J]. NATURE, 1992, 355 (6360) : 564 - 566
  • [3] INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS
    ELLINGTON, AD
    SZOSTAK, JW
    [J]. NATURE, 1990, 346 (6287) : 818 - 822
  • [4] Molecular aptamer for real-time oncoprotein platelet-derived growth factor monitoring by fluorescence anisotropy
    Fang, XH
    Cao, ZH
    Beck, T
    Tan, WH
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (23) : 5752 - 5757
  • [5] Construction and characterization of mutant water-soluble PQQ glucose dehydrogenases with altered Km values -: Site-directed mutagenesis studies on the putative active site
    Igarashi, S
    Ohtera, T
    Yoshida, H
    Witarto, AB
    Sode, K
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1999, 264 (03) : 820 - 824
  • [6] Electrochemical DNA sensor using genetically engineered thermostable pyrroloquinoline quinone glucose dehydrogenase
    Ikebukuro, K
    Saito, Y
    Igarashi, S
    Sode, K
    [J]. ELECTROCHEMISTRY, 2003, 71 (06) : 490 - 495
  • [7] Amperometric DNA sensor using the pyrroquinoline quinone glucose dehydrogenase-avidin conjugate
    Ikebukuro, K
    Kohiki, Y
    Sode, K
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) : 1075 - 1080
  • [8] Electrochemical protein chip with arrayed immunosensors with antibodies immobilized in a plasma-polymerized film
    Kojima, K
    Hiratsuka, A
    Suzuki, H
    Yano, K
    Ikebukuro, K
    Karube, I
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (05) : 1116 - 1122
  • [9] Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care hospital ambulatory patients in the United States and Canada
    Kost, GJ
    Vu, HT
    Lee, JH
    Bourgeois, P
    Kiechle, FL
    Martin, C
    Miller, SS
    Okorodudu, AO
    Podczasy, JJ
    Webster, R
    Whitlow, KJ
    [J]. CRITICAL CARE MEDICINE, 1998, 26 (03) : 581 - 590
  • [10] An aptamer-based quartz crystal protein biosensor
    Liss, M
    Petersen, B
    Wolf, H
    Prohaska, E
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (17) : 4488 - 4495