A sensitive and selective thrombin impedimetric aptasensor based on tailored aptamers obtained by solid-phase synthesis

被引:25
作者
Meini, N. [1 ,2 ]
Farre, C. [1 ]
Chaix, C. [1 ]
Kherrat, R. [2 ]
Dzyadevych, S. [3 ]
Jaffrezic-Renault, N. [1 ]
机构
[1] Univ Lyon 1, Analyt Chem Lab, F-69622 Villeurbanne, France
[2] Badji Mokhtar Univ Annaba, Lab Environm Engn, Annaba 23000, Algeria
[3] Natl Acad Sci Ukraine, Inst Mol Biol & Genet, Lab Biomol Elect, UA-03143 Kiev, Ukraine
关键词
Aptasensor; Aptamer; Thrombin; Electrochemical impedance spectroscopy; Phosphoramidite synthons; SURFACE-PLASMON RESONANCE; IMPEDANCE SPECTROSCOPY DETECTION; BIOSENSOR; PROTEINS; DNA; LIGANDS; ASSAY;
D O I
10.1016/j.snb.2012.03.046
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of the present work is to show the interest of a generic concept of aptamers directly obtained through a supported synthesis, using phosphoramidite synthons, for biosensor application. By that way, we were able to tailor the anchoring groups and specific spacers. The concept is validated on an impedimetric aptasensor for detection of thrombin. Two aptamer sequences, selected from literature (15 and 29 mers), were synthesized with a multi-thiol modification at one extremity. After their grafting on gold electrode, the faradic electrochemical impedance measurements allow the direct detection of thrombin in the range of 3-30 ng mL(-1) ancl 3-50 ng mL(- 1) for 15 meraptamer and 29 meraptamer respectively, with a detection limit of 3.1 ng mL(-1) (80 pmol/l) for both sequences. This study demonstrates that these aptasensors exhibit high sensitivity (higher sensitivity for 29 meraptamer), high selectivity (compared to a model protein, BSA), stability and reproducibility. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:715 / 720
页数:6
相关论文
共 24 条
[11]   Aptamer biosensor for label-free impedance spectroscopy detection of thrombin based on gold nanoparticles [J].
Li, Li-Dong ;
Zhao, Hong-Tao ;
Chen, Zheng-Bo ;
Mu, Xiao-Jiao ;
Guo, Lin .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (01) :189-194
[12]   Detection of protein biomarkers using RNA aptamer microarrays and enzymatically amplified surface plasmon resonance imaging [J].
Li, Yuan ;
Lee, Hye Jin ;
Corn, Robert M. .
ANALYTICAL CHEMISTRY, 2007, 79 (03) :1082-1088
[13]   Bi-cell surface plasmon resonance detection of aptamer mediated thrombin capture in serum [J].
Mani, Rinosh Joshua ;
Dye, Roman G. ;
Snider, Timothy A. ;
Wang, Shaopeng ;
Clinkenbeard, Kenneth D. .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (12) :4832-4836
[14]   Ultrasensitive detection based on an aptamer beacon electron transfer chain [J].
Mir, Monica ;
Jenkins, A. Toby A. ;
Katakis, Ioannis .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (10) :1533-1536
[15]   A novel low-cost and easy to develop functionalization platform. Case study: Aptamer-based detection of thrombin by surface plasmon resonance [J].
Polonschii, Cristina ;
David, Sorin ;
Tombelli, Sara ;
Mascini, Marco ;
Gheorghiu, Mihaela .
TALANTA, 2010, 80 (05) :2157-2164
[16]   Reusable impedimetric aptasensor [J].
Radi, AE ;
Sánchez, JLA ;
Baldrich, E ;
O'Sullivan, CK .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6320-6323
[17]   Effect of molecular crowding on the response of an electrochemical DNA sensor [J].
Ricci, Francesco ;
Lai, Rebecca Y. ;
Heeger, Alan J. ;
Plaxco, Kevin W. ;
Sumner, James J. .
Langmuir, 2007, 23 (12) :6827-6834
[18]   Aptamer biosensor for label-free impedance spectroscopy detection of proteins based on recognition-induced switching of the surface charge [J].
Rodriguez, MC ;
Kawde, AN ;
Wang, J .
CHEMICAL COMMUNICATIONS, 2005, (34) :4267-4269
[19]   Electrochemical Aptasensors [J].
Sassolas, Audrey ;
Blum, Loic J. ;
Leca-Bouvier, Beatrice D. .
ELECTROANALYSIS, 2009, 21 (11) :1237-1250
[20]   Aptamers-based assays for diagnostics, environmental and food analysis [J].
Tombelli, Sara ;
Minunni, Maria ;
Mascini, Marco .
BIOMOLECULAR ENGINEERING, 2007, 24 (02) :191-200