Non-Standardized Patch-Based ECG Lead Together With Deep Learning Based Algorithm for Automatic Screening of Atrial Fibrillation

被引:46
作者
Lai, Dakun [1 ]
Bu, Yuxiang [1 ]
Su, Ye [2 ,3 ]
Zhang, Xinshu [1 ]
Ma, Chang-Sheng [4 ]
机构
[1] Univ Elect Sci & Technol China, Sch Elect Sci & Engn, Chengdu 610054, Peoples R China
[2] Sichuan Acad Med Sci, Dept Cardiovasc Ultrasound & Cardiol, Chengdu 610072, Peoples R China
[3] Sichuan Prov Peoples Hosp, Chengdu 610072, Peoples R China
[4] Capital Med Univ, Beijing AnZhen Hosp, Dept Cardiol, Beijing 100029, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrocardiography; Lead; Standards; Rhythm; Monitoring; Detection algorithms; Digital audio players; Atrial fibrillation; convolutional neural network; electrocardiogram monitoring; patch recorder; single-lead; PREVALENCE; VALIDATION; RISK;
D O I
10.1109/JBHI.2020.2980454
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This study was to assess the feasibility of using non-standardized single-lead electrocardiogram (ECG) monitoring to automatically detect atrial fibrillation (AF) with special emphasis on the combination of deep learning based algorithm and modified patch-based ECG lead. Fifty-five consecutive patients were monitored for AF in around 24 hours by patch-based ECG devices along with a standard 12-lead Holter. Catering to potential positional variability of patch lead, four typical positions on the upper-left chest were proposed. For each patch lead, the performance of automated algorithms with four different convolutional neural networks (CNN) was evaluated for AF detection against blinded annotations of two clinicians. A total of 349,388 10-second segments of AF and 161,084 segments of sinus rhythm were detected successfully. Good agreement between patch-based single-lead and standard 12-lead recordings was obtained at the position MP1 that corresponds to modified lead II, and a promising performance of the automated algorithm with an R-R intervals based CNN model was achieved on this lead in terms of accuracy (93.1%), sensitivity (93.1%), and specificity (93.4%). The present results suggest that the optimized patch-based ECG lead along by deep learning based algorithms may offer the possibility of providing an accurate, easy, and inexpensive clinical tool for mass screening of AF.
引用
收藏
页码:1569 / 1578
页数:10
相关论文
共 28 条
[1]  
AliveCor, KARDIAMOBILE
[2]  
[Anonymous], 2017, EUROPACE, DOI DOI 10.1093/EHJCI/EUX158.263
[3]  
Battipaglia Irma, 2016, J Atr Fibrillation, V9, P1433, DOI 10.4022/jafib.1433
[4]   Smartwatch Algorithm for Automated Detection of Atrial Fibrillation [J].
Bumgarner, Joseph M. ;
Lambert, Cameron T. ;
Hussein, Ayman A. ;
Cantillon, Daniel J. ;
Baranowski, Bryan ;
Wolski, Kathy ;
Lindsay, Bruce D. ;
Wazni, Oussama M. ;
Tarakji, Khaldoun G. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (21) :2381-2388
[5]  
Calkins H, 2017, HEART RHYTHM, V14, pE445, DOI [10.1016/j.hrthm.2017.07.009, 10.1093/europace/eux275, 10.1016/j.hrthm.2017.05.012]
[6]   Development of printed and flexible dry ECG electrodes [J].
Chlaihawi, Amer Abdulmahdi ;
Narakathu, Binu Baby ;
Emamian, Sepehr ;
Bazuin, Bradley J. ;
Atashbar, Massood Z. .
SENSING AND BIO-SENSING RESEARCH, 2018, 20 :9-15
[7]   Estimates of Current and Future Incidence and Prevalence of Atrial Fibrillation in the US Adult Population [J].
Colilla, Susan ;
Crow, Ann ;
Petkun, William ;
Singer, Daniel E. ;
Simon, Teresa ;
Liu, Xianchen .
AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (08) :1142-1147
[8]  
Da He D, 2011, IEEE ENG MED BIO, P4729, DOI 10.1109/IEMBS.2011.6091171
[9]   Performance of handheld electrocardiogramdevices to detect atrial fibrillation in a cardiology and geriatric ward setting: authors' response [J].
Desteghe, Lien ;
Heidbuchel, Hein .
EUROPACE, 2017, 19 (08) :1408-1409
[10]   Short-term ECG for out of hospital detection of silent atrial fibrillation episodes [J].
Doliwa, Peter Sobocinski ;
Frykman, Viveka ;
Rosenqvist, Marten .
SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2009, 43 (03) :163-168