Wireless Powering and the Study of RF Propagation Through Ocular Tissue for Development of Implantable Sensors

被引:43
作者
Chow, Eric Y. [1 ]
Yang, Chin-Lung [2 ]
Ouyang, Yuehui [2 ]
Chlebowski, Arthur L. [1 ]
Irazoqui, Pedro P. [1 ]
Chappell, William J. [2 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, Ctr Implantable Devices, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Elect & Comp Engn, IDEAS Microwave Lab, W Lafayette, IN 47907 USA
关键词
Bio-sensor; biomedical applications of EM radiation; CMOS integrated circuits; EM propagation; implantable biomedical devices; RF powering;
D O I
10.1109/TAP.2011.2144551
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper evaluates RF powering techniques, and corresponding propagation through tissue, to supply wireless-energy for miniature implantable devices used to monitor physical-conditions in real-time. To improve efficiencies an impulsive powering technique is used with short duty-cycle high instantaneous-power-bursts, which biases the rectifier in its nonlinear regime while maintaining low average input-powers. The RF rectifier consists of a modified two-stage voltage multiplier which produces the necessary turn-on voltage for standard low-power CMOS systems while supplying the required current levels. The rectifier, fabricated on the TI 130 nm CMOS process, measures 215 mu m x 265 mu m, and is integrated with an antenna to quantify wireless performance of the power transfer. In-vivo studies performed on New Zealand white rabbits demonstrate the ability of implanted CMOS RF rectifiers to produce 1 V across a 27 k Omega load at a distance of 5 cm with a transmit-power of just over 1.5 W. Using a pulsed-powering technique, the circuit generates just under 0.9 V output with an average transmit-power of 300 mW. The effects of implantation on the propagation of RF powering waves are quantified and demonstrated to be surmountable, allowing for the ability to supply a low-power wireless sensor through a miniature rectifier IC.
引用
收藏
页码:2379 / 2387
页数:9
相关论文
共 26 条
[1]  
[Anonymous], INT TECHNOLOGY ROADM
[2]  
*ANSI, ANSIT14131995
[3]  
Chen L.J., 2004, SILICIDE TECHNOLOGY
[4]   Implantable Wireless Telemetry Boards for In Vivo Transocular Transmission [J].
Chow, Eric Y. ;
Yang, Chin-Lung ;
Chlebowski, Arthur ;
Moon, Sungwook ;
Chappell, William J. ;
Irazoqui, Pedro P. .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (12) :3200-3208
[5]  
Curty J.-P., 2005, IEEE T CIRCUITS SY 1, V52
[6]   Wireless intra-ocular pressure monitoring system integrated into an artificial lens [J].
Eggers, T ;
Draeger, J ;
Hille, K ;
Marschner, C ;
Stegmaier, P ;
Binder, J ;
Laur, R .
1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, :466-469
[7]   THE COCKCROFT-WALTON VOLTAGE MULTIPLYING CIRCUIT [J].
EVERHART, E ;
LORRAIN, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1953, 24 (03) :221-226
[8]   Resonant mechanical magnetic sensor in standard CMOS [J].
Eyre, B ;
Pister, KSJ ;
Kaiser, W .
IEEE ELECTRON DEVICE LETTERS, 1998, 19 (12) :496-498
[9]   A CMOS analog frontend for a passive UHF RFID tag [J].
Facen, Alessio ;
Boni, Andrea .
ISLPED '06: Proceedings of the 2006 International Symposium on Low Power Electronics and Design, 2006, :280-285
[10]  
GELATT KN, 1977, ANIMAL MODELS GLAUCO, V16, P592