Mechanical properties of pultruded carbon fibre-reinforced polymer (CFRP) plates at elevated temperatures

被引:205
作者
Wang, Ke [1 ]
Young, Ben [1 ]
Smith, Scott T. [1 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Hong Kong, Hong Kong, Peoples R China
关键词
CFRP; Elevated temperatures; Pultruded FRP plate; Fire resistance; High-temperature behaviour; STAINLESS-STEEL; FIRE ENDURANCE; CONCRETE SLABS; COLUMNS; COMPOSITES; SYSTEMS; MEMBERS;
D O I
10.1016/j.engstruct.2011.03.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of fibre-reinforced polymer (FRP) composites is becoming increasingly widespread in civil infrastructure for strengthening and repair applications as well as whole FRP members and structures. A question which, however, continually arises from all stake-holders is the performance of FRP materials under elevated temperatures. An accurate understanding of the material properties and behaviour of FRP at such high temperatures is crucial, and they are necessary pieces of information that are surprisingly scarce in the literature. This paper therefore presents the mechanical properties of pultruded carbon fibre-reinforced polymer (CFRP) plates at elevated temperatures. More specifically, CFRP pultruded plate coupons were tested at steady and transient states for temperatures ranging from approximately 20 to 700 degrees C. The tests showed that, for the temperature ranges 20-150 degrees C and 450-706 degrees C, reductions of the tensile strength of the pultruded CFRP plate occurred. Between these temperature ranges, the tensile strength decreased by a small amount, while at 300 degrees C the ultimate strength was approximately 50% of the room-temperature strength. In addition, the tensile strength of the plate was as low as 7% of the room-temperature tensile strength at the approximate peak temperature of 700 degrees C. Finally, an equation that relates the tensile strength of the plate to the entire tested temperature range which has been calibrated with all the test data is proposed. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2154 / 2161
页数:8
相关论文
共 27 条
[1]  
[Anonymous], FIRE TECHNOL
[2]  
[Anonymous], 2004, ACI4403R04
[3]  
Bisby L.A., 2003, PhD Thesis
[4]  
Bisby LA, 2005, ACI STRUCT J, V102, P883
[5]   Tensile Properties of CFRP and Hybrid FRP Composites at Elevated Temperatures [J].
Cao, Shenghu ;
Wu, Zhishen ;
Wang, Xin .
JOURNAL OF COMPOSITE MATERIALS, 2009, 43 (04) :315-330
[6]   Stress-strain curves for stainless steel at elevated temperatures [J].
Chen, J ;
Young, B .
ENGINEERING STRUCTURES, 2006, 28 (02) :229-239
[7]   Cold-formed steel lipped channel columns at elevated temperatures [J].
Chen, Ju ;
Young, Ben .
ENGINEERING STRUCTURES, 2007, 29 (10) :2445-2456
[8]   Experimental investigation of cold-formed steel material at elevated temperatures [J].
Chen, Ju ;
Young, Ben .
THIN-WALLED STRUCTURES, 2007, 45 (01) :96-110
[9]  
EEDSON RT, 2009, P 9 INT S FIB REINF
[10]   Fire survivability of externally bonded FRP strengthening systems [J].
Foster, S. K. ;
Bisby, L. A. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (05) :553-561