Validation and inter-laboratory study of selective hydride generation for fast screening of inorganic arsenic in seafood

被引:28
|
作者
Marschner, Karel [1 ]
Petursdottir, Asta H. [2 ]
Bucker, Patrick [3 ]
Raab, Andrea [3 ]
Feldmann, Jorg [3 ]
Mester, Zoltan [4 ]
Matousek, Tomas [1 ]
Musil, Stanislav [1 ]
机构
[1] Czech Acad Sci, Inst Analyt Chem, Veveri 97, Brno 60200, Czech Republic
[2] Matis, Res & Innovat, Vinlandsleid 12, IS-113 Reykjavik, Iceland
[3] Univ Aberdeen, Dept Chem, TESLA Trace Element Speciat Lab, Aberdeen AB24 3UE, Scotland
[4] Natl Res Council Canada, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
关键词
Inorganic arsenic; Speciation analysis; Selective hydride generation; Inductively coupled plasma mass spectrometry; Interlaboratory comparison; Certified reference materials; ATOMIC-ABSORPTION-SPECTROMETRY; FIELD DEPLOYABLE METHOD; IN-GAS-SHIELD; FLUORESCENCE SPECTROMETRY; SPECIATION ANALYSIS; RICE; FOOD; ARSENOSUGARS; OPTIMIZATION; EXTRACTION;
D O I
10.1016/j.aca.2018.11.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is advisable to monitor and regulate inorganic arsenic (iAs) in food and feedstuff. This work describes an update and validation of a method of selective hydride generation (HG) with inductively coupled plasma mass spectrometry (ICP-MS) for high-throughput screening of iAs content in seafood samples after microwave-assisted extraction with diluted nitric acid and hydrogen peroxide. High concentration of HCl (8 M) for HG along with hydrogen peroxide in samples of a same concentration as used for extraction leads to a selective conversion of iAs to volatile arsine that is released and transported to the detector. A minor contribution from methylarsonate (approximate to 20% to iAs) was found, while HG from dimethylarsinate, trimethylarsine oxide is substantially suppressed (less than 1% to iAs). Methodology was applied to Certified Reference Materials (CRMs) TORT-3, DORM-3, DORM-4, DOLT-4, DOLT-5, PRON-1, SQID-1 and ERM-CE278k, in some of them iAs has been determined for the first time, and to various seaweed samples from a local store. The results were always compared with a reference method and selectivity of iAs determination was evaluated. An inter-laboratory reproducibility was tested by comparative analyses of six fish and four seaweed samples in three European laboratories, with good agreement of the results. The method of HG-ICP-MS is sensitive (limit of detection 2 mg kg(-1) iAs), well suited for screening of large number of samples and selective at iAs concentration levels at which maximum limits are expected to be set into EU legislation for marine samples. Crown Copyright (C) 2018 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 28
页数:9
相关论文
共 50 条
  • [21] Validation of intra- and inter-laboratory reproducibility of the Xpert HPV assay according to the international guidelines for cervical cancer screening
    Akbari, Ajmal
    Vanden Broeck, Davy
    Benoy, Ina
    Padalko, Elizaveta
    Bogers, Johannes
    Arbyn, Marc
    VIROLOGY JOURNAL, 2018, 15
  • [22] An inter-laboratory cross-validation study for the determination of perampanel in human plasma by liquid chromatography assays
    Mano, Yuji
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (12) : 2067 - 2069
  • [23] Inter-laboratory proficiency testing scheme for tumour next-generation sequencing in Ontario: a pilot study
    Spence, T.
    Stickle, N.
    Yu, C.
    Chow, H.
    Feilotter, H.
    Lo, B.
    McCready, E.
    Sadikovic, B.
    Siu, L. L.
    Bedard, P. L.
    Stockley, T. L.
    CURRENT ONCOLOGY, 2019, 26 (06) : E717 - E732
  • [24] Sequential spectrophotometric determination of inorganic arsenic species by hydride generation from selective medium reactions and colour bleaching of permanganate
    Hashemi, M.
    Modasser, P.
    TALANTA, 2007, 73 (01) : 166 - 171
  • [25] Optimization of the solubilization, extraction and determination of inorganic arsenic [As(III)+As(V)] in seafood products by acid digestion, solvent extraction and hydride generation atomic absorption spectrometry
    Muñoz, O
    Vélez, D
    Montoro, R
    ANALYST, 1999, 124 (04) : 601 - 607
  • [26] Method validation studies and an inter-laboratory cross validation study of lenvatinib assay in human plasma using LC-MS/MS
    Mano, Yuji
    PRACTICAL LABORATORY MEDICINE, 2018, 12
  • [27] The OECD validation program of the H295R steroidogenesis assay: Phase 3. Final inter-laboratory validation study
    Hecker, Markus
    Hollert, Henner
    Cooper, Ralph
    Vinggaard, Anne Marie
    Akahori, Yumi
    Murphy, Margaret
    Nellemann, Christine
    Higley, Eric
    Newsted, John
    Laskey, John
    Buckalew, Angela
    Grund, Stefanie
    Maletz, Sibylle
    Giesy, John
    Timm, Gary
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2011, 18 (03) : 503 - 515
  • [28] Validation of an analytical method for the determination of inorganic, organic, and total arsenic in fish sauce based on hydride generation atomic absorption spectrometry
    Le, D., V
    Phan, T. L.
    Tran, Q. H.
    INTERNATIONAL FOOD RESEARCH JOURNAL, 2021, 28 (06): : 1164 - 1170
  • [29] The OECD validation program of the H295R steroidogenesis assay: Phase 3. Final inter-laboratory validation study
    Markus Hecker
    Henner Hollert
    Ralph Cooper
    Anne Marie Vinggaard
    Yumi Akahori
    Margaret Murphy
    Christine Nellemann
    Eric Higley
    John Newsted
    John Laskey
    Angela Buckalew
    Stefanie Grund
    Sibylle Maletz
    John Giesy
    Gary Timm
    Environmental Science and Pollution Research, 2011, 18 : 503 - 515
  • [30] SELECTIVE REDUCTION OF ARSENIC SPECIES BY CONTINUOUS HYDRIDE GENERATION .2. VALIDATION OF METHODS FOR APPLICATION TO NATURAL-WATERS
    ANDERSON, RK
    THOMPSON, M
    CULBARD, E
    ANALYST, 1986, 111 (10) : 1153 - 1158