Sphere-Shaped Receiver Coil for Misalignment-Resilient Wireless Power Transfer Systems for Implantable Devices

被引:22
作者
Basir, Abdul [1 ]
Shah, Izaz Ali [1 ]
Yoo, Hyoungsuk [1 ]
机构
[1] Hanyang Univ, Dept Elect Engn, Seoul 04763, South Korea
基金
新加坡国家研究基金会;
关键词
Efficiency; implantable device; inductive coupling; misalignments; voltage-doubler; wireless charging; ANTENNA; DESIGN; BIOTELEMETRY; TRANSMISSION;
D O I
10.1109/TAP.2022.3161268
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Positional misalignments of coils cause a sharp drop in the power transfer efficiency (PTE) of wireless power transfer (WPT) systems. To minimize this deterioration of the PTE, this study introduces a sphere-shaped (Rxs) to a three-coil magnetic resonance-coupled WPT system for implantable devices. To assess the significance of Rxs, its performance was compared to the well-known circular planar (Rxf), half-sphere-shaped (Rxhs), and solenoid (Rsl) coils. Moreover, a small and efficient voltage doubler as a rectifier was designed. This voltage doubler has a high conversion efficiency of 89% with an output voltage of >3 V at 15 dBm. To validate the concept, prototypes of the coils and voltage doubler were fabricated and measured in saline and minced pork. The PTEs of the Rxf, Rxhs, Rsl, and Rxs coils-based WPT systems were studied under different lateral and angular misalignments in both simulations and measurements. In perfect alignment conditions, the measured PTEs of Rxf, Rxhs, Rsl, and Rxs WPT systems were 7.68%, 10.18%, 25.01%, and 22.38%, respectively; however, when the (Rx) receiver coils rotated by 90 degrees, the PTEs were 0%, <0.2%, 0.15%, and 5.4%, respectively. Under lateral misalignments of dx = 25 mm, the PTEs were 0.82%, 1.91%, 2.4%, and 4.87%, respectively. Furthermore, the PTE for the Rxs-based WPT system was measured in saline- and minced-pork-filled boxes and a saline-filled American Society for Testing and Materials (ASTM) model under different misalignment conditions to expand its applicability range to deep-body nonstatic implants. Both the simulated and remeasured results show that the proposed Rxs-based WPT system presented an improved and stabilized PTE under positional misalignments.
引用
收藏
页码:8368 / 8378
页数:11
相关论文
共 42 条
[1]   Wireless Power Transfer Strategies for Implantable Bioelectronics [J].
Agarwal, Kush ;
Jegadeesan, Rangarajan ;
Guo, Yong-Xin ;
Thakor, Nitish V. .
IEEE Reviews in Biomedical Engineering, 2017, 10 :136-161
[2]   Design and In Vivo Test of a Batteryless and Fully Wireless Implantable Asynchronous Pacing System [J].
Asif, Sajid M. ;
Hansen, Jared ;
Khan, Muhammad S. ;
Walden, Scott D. ;
Jensen, Mark O. ;
Braaten, Benjamin D. ;
Ewert, Daniel L. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (05) :1070-1081
[3]   An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope [J].
Basar, Md. Rubel ;
Ahmad, Mohd Yazed ;
Cho, Jongman ;
Ibrahim, Fatimah .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (10) :7772-7781
[4]   Stable and High-Efficiency Wireless Power Transfer System for Robotic Capsule Using a Modified Helmholtz Coil [J].
Basar, Md Rubel ;
Ahmad, Mohd Yazed ;
Cho, Jongman ;
Ibrahim, Fatimah .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (02) :1113-1122
[5]  
Basir A, 2020, IEEE MTT S INT MICR, P496, DOI 10.1109/IMS30576.2020.9223826
[6]   A Dual-Circular-Polarized Endoscopic Antenna With Wideband Characteristics and Wireless Biotelemetric Link Characterization [J].
Basir, Abdul ;
Zada, Muhammad ;
Cho, Youngdae ;
Yoo, Hyoungsuk .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2020, 68 (10) :6953-6963
[7]   Efficient Wireless Power Transfer System With a Miniaturized Quad-Band Implantable Antenna for Deep-Body Multitasking Implants [J].
Basir, Abdul ;
Yoo, Hyoungsuk .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2020, 68 (05) :1943-1953
[8]   Passive Impedance Matching for Implanted Brain-Electrode Interfaces [J].
Chen, Wei-Chuan ;
Guido, Katrina ;
Kiourti, Asimina .
IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2019, 3 (04) :233-239
[9]   A Multi-Channel Passive Brain Implant for Wireless Neuropotential Monitoring [J].
Chen, Wei-Chuan ;
Lee, Cedric W. L. ;
Kiourti, Asimina ;
Volakis, John L. .
IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2018, 2 (04) :262-269
[10]   A Metamaterial-Coupled Wireless Power Transfer System Based on Cubic High-Dielectric Resonators [J].
Das, Rupam ;
Basir, Abdul ;
Yoo, Hyoungsuk .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (09) :7397-7406