Comparison of a new optical biometry with an optical low-coherence reflectometry for ocular biometry

被引:13
作者
Guler, Emre [1 ]
Kulak, Ali Ender [2 ]
Totan, Yuksel [3 ]
Yuvarlak, Armagan [4 ]
Hepsen, Ibrahim Feyzi [4 ]
机构
[1] Turkiye Hosp, Eye Clin, Istanbul, Turkey
[2] Bogazliyan State Hosp, Eye Clin, Yozgat, Turkey
[3] Turgut Ozal Univ, Sch Med, Dept Ophthalmol, Ankara, Turkey
[4] Gazi Univ, Sch Med, Dept Ophthalmol, Ankara, Turkey
关键词
AL-Scan; Lenstar; Repeatability; Agreement; Cataract; INTRAOCULAR-LENS POWER; CALCULATION FORMULAS; STATISTICAL-METHODS; DEVICE; AGREEMENT; ACCURACY; STANDARD; MYOPIA; ERROR;
D O I
10.1016/j.clae.2016.06.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To evaluate the repeatability and agreement of a new partial coherence interferometry optical biometer (AL-Scan, Nidek CO, Aichi, Japan) with optical low-coherence reflectometry device (Lenstar LS 900, Haag-Streit AG, Koniz, Switzerland). Methods: Three consecutive measurements with the 2 devices were performed by the same examiner in 65 eyes of 65 patients with cataract. Patients were divided into 2 groups: axial length (AL) between 22 and 26 mm (Group 1) and more than 26 mm (Group 2). Comparisons were performed for AL, anterior chamber depth (ACD), keratometry (K, over 2.4 mm diameter for AL-Scan and 2.3 mm diameter for Lenstar) and corneal diameter (CD). Repeatability was analyzed using the intraclass correlation coefficient (ICC) and the agreement was by the Bland-Altman method. Results: The repeatability of both devices was high for all biometry measurements (ICC over 0.970) in Group 1 and 2. The best repeatability was achieved for AL in each group. In both groups, the differences were statistically significant for all parameters (p < 0.05) except for the measurement of AL and CCT (p > 0.05). The Bland-Altman analysis showed good agreement between devices for all measurements in both groups. The closest agreement was for the AL measurements (ranged from -0.06 to 0.08 mm in Group 1 and 0.05-0.07 mm in Group 2). Conclusions: The new biometer provided excellent repeatability for all ocular biometry. In addition, there was good agreement between AL-Scan and Lenstar biometers for all parameters in cataractous patients with medium and long ALs. (C) 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:336 / 341
页数:6
相关论文
共 21 条
[1]  
Bland JM, 1996, BRIT MED J, V313, P744
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[4]   Evaluation of the Lenstar LS 900 non-contact biometer [J].
Cruysberg, L. P. J. ;
Doors, M. ;
Verbakel, F. ;
Berendschot, T. T. J. M. ;
De Brabander, J. ;
Nuijts, R. M. M. A. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (01) :106-110
[5]   Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[6]   Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMaster [J].
Huang, Jinhai ;
Savini, Giacomo ;
Li, Jian ;
Lu, Weicong ;
Wu, Fan ;
Wang, Jing ;
Li, Yaolin ;
Feng, Yifan ;
Wang, Qinmei .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (09) :1277-1281
[7]  
Joo Jongsoo, 2011, Korean J Ophthalmol, V25, P375, DOI 10.3341/kjo.2011.25.6.375
[8]   Biommetry and intraocular lens power calculation results with a new optical biometry device: Comparison with the gold standard [J].
Kaswin, Godefroy ;
Rousseau, Antoine ;
Mgarrech, Mohamed ;
Barreau, Emmanuel ;
Labetoulle, Marc .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (04) :593-600
[9]  
KORA Y, 1991, OPHTHALMIC SURG LAS, V22, P78
[10]   Biometry and intraocular lens power calculation [J].
Lee, Alexander C. ;
Qazi, Mujtaba A. ;
Pepose, Jay S. .
CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (01) :13-17