Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures

被引:31
|
作者
Lever, James P. [2 ]
Aksenov, Sergei A. [2 ]
Zdero, Rad [1 ]
Ahn, Henry [2 ]
Mckee, Michael D. [2 ]
Schemitsch, Emil H. [1 ,2 ]
机构
[1] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Univ Toronto, Dept Surg, Toronto, ON, Canada
关键词
biomechanics; proximal humerus; fracture; plate fixation;
D O I
10.1097/BOT.0b013e31815c89ce
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To biomechanically assess five proximal, humeral, fracture-plate-fixation systems. Methods: Surgical neck fractures, with and without cortical contact, were created in 25 fresh-frozen cadaveric humeri. Five methods of plate fixation were used for repair: construct A [an eight-hole, low contact dynamic compression (LCDC) plate contoured into a blade shape, supported by one, 70-mm-long, 4.5-mm-diameter cortical screw acting as a truss], construct B (a 10-hole LCDC plate arrangement identical to construct A, but using one, 70-mm-long, 3.5-mm-diameter cortical screw as a truss), construct C [a five-hole dynamic compression (DC) blade plate with one, 6.5-mm-diameter cancellous screw], construct D (a five-hole T-plate supported by three, 6.5-mm-diameter cancellous screws), and construct E (a five-hole cloverleaf plate supported by five, 4-mm-diameter cancellous screws). Plates were posterior to the bicipital groove, 10 mm distal to the greater tuberosity tip, on the lateral aspect of the humeral shaft. Screw fixation was done using standard AO compression plating techniques. Stiffness of constructs was measured in bending and axial compression. Locked plates were not assessed. Results: For cortical contact [abduction of 20 degrees (P = 0.02), flexion of 20 degrees (P = 0.02), flexion of 90 degrees (P = 0.005)] and no cortical contact [flexion of 90 degrees (P = 0.0001)], construct A was significantly stiffer than other constructs. For no cortical contact in abduction of 90 degrees (P = 0.05), construct A was significantly stiffer than other constructs. Conclusions: Construct A was significantly stiffer than other constructs.
引用
收藏
页码:23 / 29
页数:7
相关论文
共 50 条
  • [21] Complications Associated with Locking Plate of Proximal Humerus Fractures
    Kavuri, Venkat
    Bowden, Blake
    Kumar, Neil
    Cerynik, Doug
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (02) : 108 - 116
  • [22] Biomechanical study of different plate configurations for distal humerus osteosynthesis
    Bogataj, M.
    Kosel, F.
    Norris, R.
    Krkovic, M.
    Brojan, M.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (05) : 381 - 392
  • [23] Biomechanical study of different plate configurations for distal humerus osteosynthesis
    M. Bogataj
    F. Kosel
    R. Norris
    M. Krkovic
    M. Brojan
    Medical & Biological Engineering & Computing, 2015, 53 : 381 - 392
  • [24] Hinge plate technique for osteosynthesis of comminuted proximal humeral fractures
    Habib, Nermine
    Fornaciari, Paolo
    Thuerig, Gregoire
    Maniglio, Mauro
    Tannast, Moritz
    Vial, Philippe
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (08): : 2292 - 2299
  • [25] Dual plate for comminuted proximal humerus fractures
    Choi, Sungwook
    Seo, Kyu-Bum
    Kwon, Yong Suk
    Kang, Hyunseong
    Cho, Changhee
    Rho, Joseph Y.
    ACTA ORTHOPAEDICA BELGICA, 2019, 85 (04): : 429 - 436
  • [26] A Methodology for Biomechanical Assessment of Proximal Humerus Fractures Using an Integrated Experimental and Computational Framework
    Jabran, Ali
    Ren, Lei
    Peach, Chris
    Zou, Zhenmin
    SECOND CIRP CONFERENCE ON BIOMANUFACTURING, 2016, 49 : 139 - 142
  • [27] Prospective outcome analysis following tenodesis of the long head of the biceps tendon along with locking plate osteosynthesis for proximal humerus fractures
    Greve, F.
    Beirer, M.
    Zyskowski, M.
    Croenlein, M.
    Mueller, M.
    Pesch, S.
    Felix, S.
    Biberthaler, P.
    Buchholz, A.
    Kirchhoff, C.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (03): : 681 - 685
  • [28] Osteosynthesis of supracondylar humerus fractures in children: A biomechanical comparison of four techniques
    Weinberg, A. M.
    Castellani, C.
    Arzdorf, M.
    Schneider, E.
    Gasser, B.
    Linke, B.
    CLINICAL BIOMECHANICS, 2007, 22 (05) : 502 - 509
  • [29] Biomechanical Evaluation of Plate Osteosynthesis of Distal Fibula Fractures with Biodegradable Devices
    Klos, Kajetan
    Sauer, Stefanie
    Hoffmeier, Konrad
    Gras, Florian
    Froeber, Rosemarie
    Hofmann, Gunther O.
    Mueckley, Thomas
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (03) : 243 - 251
  • [30] Biomechanical comparison of two angle-stable, anatomically designed plate systems on distal humerus fractures
    Hungerer, S.
    Penzkofer, R.
    Augat, P.
    Buehren, V.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2010, 5 (03): : 165 - 172