Residual set-up errors and margins in on-line image-guided prostate localization in radiotherapy

被引:32
|
作者
Poulsen, Per Rugaard [1 ,2 ]
Muren, Ludvig Paul [1 ]
Hoyer, Morten [3 ]
机构
[1] Aarhus Univ Hosp, Dept Phys Med, DK-8000 Aarhus C, Denmark
[2] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA USA
[3] Aarhus Univ Hosp, Dept Oncol, Aarhus, Denmark
关键词
prostate cancer; prostate localization; image-guided radiotherapy; set-up accuracy;
D O I
10.1016/j.radonc.2007.08.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Image-guided on-line correction of the target position allows radiotherapy of prostate cancer with narrow set-up margins. The present study investigated the residual set-up error after on-line prostate localization and its impact on margins. Materials and methods: Prostate localization based on two orthogonal X-ray images of gold markers implanted in the prostate was performed with an on-board imager at four treatment sessions for 90 patients. The set-up error in the sagittal plane residual after couch adjustment was evaluated on lateral verification portal images. Results: The set-up error was less than 3.0 mm in 92% of the cases in the anterior-posterior (AP) direction and in 95% of the cases in the cranio-caudal (CC) direction. The set-up error was dominated by internal prostate motion taking place during the set-up procedure. Set-up margins were calculated using two formalisms: margins designed to ensure a minimum CTV dose of 95% for 90% of the patient population were 3.6 mm (AP) and 3.5 mm (CC). Patient-independent normal distributed set-up errors would result in margins of 4.3 mm (AP) and 4.0 mm (CC) to ensure complete CTV inclusion in the PTV with 90% probability. Conclusion: Internal prostate motion during the set-up procedure was the main contributor to residual set-up errors. (c) 2007 Elsevier Ireland Ltd. ALL rights reserved.
引用
收藏
页码:201 / 206
页数:6
相关论文
共 50 条
  • [41] Image-guided radiotherapy for hypofractionated treatment of prostate
    Garibaldi, C.
    Zerini, D.
    Cambria, R.
    Tagaste, B.
    Fossa, B. Jereczek
    Cattani, F.
    Ferrariz, AM.
    Serafini, F.
    Orecchia, R.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S171 - S171
  • [42] Simultaneous evaluation of daily on-line set-up errors and organ motion uncertainty during conformal radiation treatment of the prostate
    Jiang, R.
    Osei, E.
    Barnett, R.
    Fleming, K.
    Panjwani, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S68 - S68
  • [43] Daily on-line set-up correction in 3D-conformal radiotherapy: is it feasible?
    Deodato, Francesco
    Cilla, Savino
    Massaccesi, Mariangela
    Macchia, Gabriella
    Ippolito, Edy
    Caravatta, Luciana
    Picardi, Vincenzo
    Romanella, Michele
    Di Falco, Carlo
    Bartollino, Alessandra
    Valentini, Vincenzo
    Cellini, Numa
    De Spirito, Marco
    Piermattei, Angelo
    Morganti, Alessio G.
    TUMORI, 2012, 98 (04) : 441 - 444
  • [44] IMPACT OF PORTAL IMAGES FREQUENCY ON PATIENTS' SET-UP ERRORS DURING PROSTATE CANCER RADIOTHERAPY
    Korytkowska, J.
    Skorska, M.
    Ryczkowski, A.
    Bak, B.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S582 - S582
  • [45] SYSTEMIC AND RANDOM SET-UP ERRORS IN RADIOTHERAPY OF PROSTATE CANCER USING KV-CBCT.
    Machanova, M.
    Richter, V.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S342 - S342
  • [46] Optimizing radiotherapy for locally advanced prostate cancer with IMRT and image-guided tumor localization
    Lohr, F
    Fuss, M
    Tiefenbacher, U
    Siegsmund, M
    Mai, S
    Kunnappallil, JM
    Dobler, B
    Alken, P
    Wenz, F
    UROLOGE A, 2004, 43 (01): : 43 - +
  • [47] CT image fusion as a tool to measure the 3D set-up errors during conformal radiotherapy for prostate cancer
    Cambria, R
    Ciocca, M
    Cattani, F
    Garibaldi, C
    Castiglioni, S
    Tosi, G
    Orecchia, R
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S410 - S411
  • [48] Surface guided radiotherapy for prostate cancer: a single institution review of set up errors
    Walsh, Jessica
    Bennett, Erica
    Barry, Laura
    England, Andrew
    Devine, Annemarie
    McEntee, Mark
    Donovan, Theresa O'
    Kelly, Paul
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S5602 - S5604
  • [49] Dosimetric impact of set-up errors and anatomy changes in CBCT-guided accelerated partial breast irradiation: towards evidence-based set-up margins
    Frederick, Amy
    Quirk, Sarah
    Roumeliotis, Michael
    MEDICAL PHYSICS, 2019, 46 (11) : 5395 - 5396
  • [50] On-line mobility analyzer: Set-up and first measurements
    J Aerosol Sci, Suppl 1 (S771):