Background and purpose: Image-guided on-line correction of the target position allows radiotherapy of prostate cancer with narrow set-up margins. The present study investigated the residual set-up error after on-line prostate localization and its impact on margins. Materials and methods: Prostate localization based on two orthogonal X-ray images of gold markers implanted in the prostate was performed with an on-board imager at four treatment sessions for 90 patients. The set-up error in the sagittal plane residual after couch adjustment was evaluated on lateral verification portal images. Results: The set-up error was less than 3.0 mm in 92% of the cases in the anterior-posterior (AP) direction and in 95% of the cases in the cranio-caudal (CC) direction. The set-up error was dominated by internal prostate motion taking place during the set-up procedure. Set-up margins were calculated using two formalisms: margins designed to ensure a minimum CTV dose of 95% for 90% of the patient population were 3.6 mm (AP) and 3.5 mm (CC). Patient-independent normal distributed set-up errors would result in margins of 4.3 mm (AP) and 4.0 mm (CC) to ensure complete CTV inclusion in the PTV with 90% probability. Conclusion: Internal prostate motion during the set-up procedure was the main contributor to residual set-up errors. (c) 2007 Elsevier Ireland Ltd. ALL rights reserved.
引用
收藏
页码:201 / 206
页数:6
相关论文
共 50 条
  • [1] Automatic localization of the prostate for on-line image-guided radiotherapy
    Smitsmans, MHP
    Wolthaus, JWH
    Artignan, X
    De Bois, J
    Jaffray, DA
    Lebesque, JV
    Van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S23 - S23
  • [2] IMAGE-GUIDED RADIOTHERAPY (IGRT) FOR PROSTATE CANCER: EFFECT OF RESIDUAL SET-UP ERRORS AND INTRA-FRACTIONAL MOTION ON PLANNING TARGET VOLUME (PTV) MARGINS.
    Benson, R.
    Rimmer, Y.
    Tudor, S.
    Dean, J.
    Muskett, N.
    Patterson, H.
    Russell, S.
    Woodward, C.
    Fairfoul, J.
    Doble, A.
    Burnet, N.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S373 - S373
  • [3] Automatic localization of the prostate for on-line or off-line image-guided radiotherapy
    Smitsmans, MHP
    Wolthaus, JWH
    Artignan, X
    De Bois, J
    Jaffray, DA
    Lebesque, JV
    Van Herk, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02): : 623 - 635
  • [4] The impact of reference isocentre position on set-up errors in head-and-neck image-guided radiotherapy
    Lenko, Helena
    Peterlin, Primoz
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 104 - 113
  • [5] An Evaluation of Translational Set-Up Errors to Define An Institutional Protocol for Set-Up Margins in the Treatment of Cancer Cervix Using Image Guided Radiotherapy (IGRT)
    Rani, G.
    Kaur, H.
    Ninan, J.
    Chandrasenan, P.
    Abdussameeh, M. P.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [6] Set-up errors and planning margins in planar and CBCT image-guided radiotherapy using three different imaging systems: A clinical study for prostate and head-and-neck cancer
    Dzierma, Yvonne
    Beyhs, Monica
    Palm, Jan
    Niewald, Marcus
    Bell, Katharina
    Nuesken, Frank
    Licht, Norbert
    Ruebe, Christian
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 1055 - 1059
  • [7] Modeling and prediction of set-up errors in breast cancer image-guided radiotherapy using the Gaussian mixture model
    Dong, Fangfen
    Chen, Jing
    Liu, Feiyu
    Yang, Zhiyu
    Wu, Yimin
    Li, Xiaobo
    ONCOLOGY LETTERS, 2024, 28 (06)
  • [8] Adaptive set-up correction (ASC) to account for set-up errors in prostate radiotherapy
    Lauve, A
    Siebers, J
    Crimaldi, A
    Hagan, M
    Keall, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S332 - S332
  • [9] Image-guided radiation therapy for carcinoma of gallbladder: implication on margin for set-up errors
    Saini, Gagan
    Goel, Vineeta
    Anand, Anil K.
    Gupta, Kamlesh Kumar
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2013, 12 (03) : 263 - 271
  • [10] Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markers
    Wu, J
    Haycocks, T
    Alasti, H
    Ottewell, G
    Middlemiss, N
    Abdolell, M
    Warde, P
    Toi, A
    Catton, C
    RADIOTHERAPY AND ONCOLOGY, 2001, 61 (02) : 127 - 133