Reproduction of fretting wear at the stem-cement interface in total hip replacement

被引:19
作者
Brown, L. [1 ]
Zhang, H. [1 ]
Blunt, L. [1 ]
Barrans, S. [1 ]
机构
[1] Univ Huddersfield, Sch Computing & Engn, Ctr Precis Technol, Huddersfield HD1 3DH, W Yorkshire, England
关键词
simulation; fretting wear; stem-cement interface; total hip replacement;
D O I
10.1243/09544119JEIM333
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The stem-cement interface experiences fretting wear in vivo due to low-amplitude oscillatory micromotion under physiological loading, as a consequence it is considered to play an important part in the overall wear of cemented total hip replacement. Despite its potential significance, in-vitro simulation to reproduce fretting wear has seldom been attempted and even then with only limited success. In the present study, fretting wear was successfully reproduced at the stem-cement interface through an in-vitro wear simulation, which was performed in part with reference to ISO 7206-4: 2002. The wear locations compared well with the results of retrieval studies. There was no evidence of bone cement transfer films on the stem surface and no fatigue cracks in the cement mantle. The cement surface was severely damaged in those areas in contact with the fretting zones on the stem surface, with retention of cement debris in the micropores. Furthermore, it was suggested that these micropores contributed to initiation and propagation of fretting wear. This study gave scope for further comparative study of the influence of stem geometry, stem surface finish, and bone cement brand on generation of fretting wear.
引用
收藏
页码:963 / 971
页数:9
相关论文
共 35 条
[1]  
[Anonymous], 1979, CLIN ORTHOP RELAT RE
[2]   A novel test method for evaluation of the abrasive wear behaviour of total hip stems at the interface between implant surface and bone cement [J].
Bader, R ;
Steinhauser, E ;
Holzwarth, U ;
Schmitt, M ;
Mittelmeier, W .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2004, 218 (H4) :223-230
[3]   Porosity reduction in bone cement at the cement-stem interface [J].
Bishop, NE ;
Ferguson, S ;
Tepic, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (03) :349-356
[4]  
Brown LT, 2006, THESIS U HUDDERSFIEL
[5]  
COOK JE, 1998, THESIS U EXETER EXTE
[6]   Comparative in vitro study on the long term performance of cemented hip stems: validation of a protocol to discriminate between "good" and "bad" designs [J].
Cristofolini, L ;
Teutonico, AS ;
Monti, L ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 2003, 36 (11) :1603-1615
[7]  
CROWNINSHIELD RD, 1998, CLIN ORTHOP RELAT R, V355, P90
[8]   Simulation of fretting wear at orthopaedic implant interfaces [J].
Ebramzadeh, E ;
Billi, F ;
Sangiorgio, SN ;
Mattes, S ;
Schmoelz, W ;
Dorr, L .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03) :357-363
[9]   Multi-technique characterization of retrieved bone cement from revised total hip arthroplasties [J].
Eliades, T ;
Papadopulos, JS ;
Eliades, G ;
Silikas, N ;
Watts, DC .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2003, 14 (11) :967-972
[10]   Alumina-alumina artificial hip joints. Part I: a histological analysis and characterisation of wear debris by laser capture microdissection of tissues retrieved at revision [J].
Hatton, A ;
Nevelos, JE ;
Nevelos, AA ;
Banks, RE ;
Fisher, J ;
Ingham, E .
BIOMATERIALS, 2002, 23 (16) :3429-3440