QUALITY ASSESSMENT OF FRAMELESS FRACTIONATED STEREOTACTIC RADIOTHERAPY USING CONE BEAM COMPUTED TOMOGRAPHY

被引:16
作者
Peng, Lee-Cheng [2 ]
Kahler, Darren
Samant, Sanjiv
Li, Jonathan
Amdur, Robert
Palta, Jatinder R.
Liu, Chihray [1 ]
机构
[1] Univ Florida, Dept Radiat Oncol, Hlth Sci Ctr, Coll Med, Gainesville, FL 32610 USA
[2] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32610 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2010年 / 78卷 / 05期
关键词
Fractional stereotactic radiotherapy; CBCT; High-precision radiotherapy; Setup uncertainty; Optical tracking; RADIATION-THERAPY; TARGET LOCALIZATION; ACCURACY; ASSURANCE; SYSTEMS; IMMOBILIZATION; GUIDANCE; SETUP;
D O I
10.1016/j.ijrobp.2010.02.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose A quality assessment of intracranial stereotactic radiotherapy was performed using cone beam computed tomography (CBCT) Setup errors were analyzed for two groups of patients (I) those who were positioned using a frameless SonArray (FSA) system and immobilized with a bite plate and thermoplastic (TP) mask (the bFSA group), and (2) those who were positioned by room laser and immobilized using a TP mask (the mLAS group) Methods and Materials A quality assurance phantom was used to study the system differences between FSA and CBCT The quality assessment was performed using an Elekta Synergy imager (XVI) (Elekta Oncology Systems, Norcross, GA) and an On-Board Imager (OBI) (Varian Medical Systems, Palo Alto, CA) for 25 patients For the first three fractions, and weekly thereafter, the FSA system was used for patient positioning, after which CBCT was performed to obtain setup errors Results (1) Phantom tests The mean differences in the isocenter displacements for the two systems was 1 2 +/- 0 7 mm No significant variances were seen between the XVI and OBI units (p similar to 0 208) (2)Patient tests The mean of the displacements between FSA and CBCT were independent of the CBCT system used, mean setup errors for the bESA group were smaller (1 2 mm) than those of the mLAS group (3 2 mm) (p < 0 005) For the mLAS patients, the 90th percentile and the maximum rotational displacements were 3 degrees and 5 degrees, respectively A 4-mm drift in setup accuracy occurred over the treatment course for 1 bFSA patient Conclusions System differences of less than 1 mm between CBCT and FSA were seen Error regression was observed for the bFSA patients, using CBCT (up to 4 mm) during the treatment course For the mLAS group, daily CBCT imaging was needed to obtain acceptable setup accuracies (C) 2010 Elsevier Inc
引用
收藏
页码:1586 / 1593
页数:8
相关论文
共 21 条
[1]   Repositioning accuracy of fractionated stereotactic irradiation: assessment of isocentre alignment for different dental fixations by using sequential CT scanning [J].
Baumert, BG ;
Egli, P ;
Studer, S ;
Dehing, C ;
Davis, JB .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (01) :61-66
[2]   Quality assurance for the geometric accuracy of cone-beam CT guidance in radiation therapy [J].
Bissonnette, Jean-Pierre ;
Moseley, Doug ;
White, Elizabeth ;
Sharpe, Michael ;
Purdie, Tom ;
Jaffray, David A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01) :S57-S61
[3]   The university of Florida frameless high-precision stereotactic radiotherapy system [J].
Bova, FJ ;
Buatti, JM ;
Friedman, WA ;
Mendenhall, WM ;
Yang, CC ;
Liu, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (04) :875-882
[4]   Preliminary experience with frameless stereotactic radiotherapy [J].
Buatti, JM ;
Bova, FJ ;
Friedman, WA ;
Meeks, SL ;
Marcus, RB ;
Mickle, JP ;
Ellis, TL ;
Mendenhall, WM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :591-599
[5]   Accuracy and feasibility of cone-beam computed tomography for stereotactic radiosurgery setup [J].
Chang, Jenghwa ;
Yenice, Kamil M. ;
Narayana, Ashwatha ;
Gutin, Philip H. .
MEDICAL PHYSICS, 2007, 34 (06) :2077-2084
[6]   Intra- and interfractional patient motion for a variety of immobilization devices [J].
Engelsman, M ;
Rosenthal, SJ ;
Michaud, SL ;
Adams, JA ;
Schneider, RJ ;
Bradley, SG ;
Flanz, JB ;
Kooy, HM .
MEDICAL PHYSICS, 2005, 32 (11) :3468-3474
[7]   Reliability of the bony anatomy in image-guided stereotactic radiotherapy of brain metastases [J].
Guckenberger, Matthias ;
Baier, Kurt ;
Guenther, Iris ;
Richter, Anne ;
Wilbert, Juergen ;
Sauer, Otto ;
Vordermark, Dirk ;
Flentje, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01) :294-301
[8]  
HEGGEMANN JB, 2006, INT J RADIAT ONCOL, V66, P1568
[9]  
Herbert Clare E, 2003, Med Dosim, V28, P27, DOI 10.1016/S0958-3947(02)00142-5
[10]   2D/3D image fusion for accurate target localization and evaluation of a mask based stereotactic system in fractionated stereotactic radiotherapy of cranial lesions [J].
Jin, Jian-Yue ;
Ryu, Samuel ;
Faber, Kathleen ;
Mikkelsen, Tom ;
Chen, Qing ;
Li, Shidong ;
Movsas, Benjamin .
MEDICAL PHYSICS, 2006, 33 (12) :4557-4566