Explantation of the Novel Ahmed Glaucoma Valve M4 Implant

被引:4
|
作者
Hu, Wanda D. [1 ]
Pro, Michael J. [1 ]
Fudemberg, Scott J. [1 ]
Moster, Marlene R. [1 ]
机构
[1] Wills Eye Hosp & Res Inst, Philadelphia, PA 19107 USA
关键词
glaucoma; drainage device; tube shunt; polyethylene; Ahmed Glaucoma Valve; explantation; CLINICAL-EXPERIENCE; DRAINAGE DEVICES; COMPLICATIONS; OUTCOMES;
D O I
10.1097/IJG.0000000000000192
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report a series of cases involving Ahmed Glaucoma Valve M4 (AGV) explantation and to discuss the surgical technique to remove the drainage device. Methods: Four cases were identified that presented with AGV M4 postoperative complications necessitating tube shunt removal. Three patients presented with conjunctival erosion and 1 patient with persistent diplopia. AGV M4 implants were removed successfully between 1.5 and 9 months after implantation. Results: Successful explantation of the AGV M4 novel implant was achieved in all cases without intraoperative or postoperative complications. Conclusions: If necessary, AGV M4 explantation can be successfully performed in the early postoperative period.
引用
收藏
页码:E1 / E4
页数:4
相关论文
共 50 条
  • [1] Initial Experience With the New Ahmed Glaucoma Valve Model M4: Short-term Results
    Cvintal, Victor
    Moster, Marlene R.
    Shyu, Andrew P.
    McDermott, Katie
    Ekici, Feyzahan
    Pro, Michael J.
    Waisbourd, Michael
    JOURNAL OF GLAUCOMA, 2016, 25 (05) : E475 - E480
  • [2] Safety and Efficacy of Second Ahmed Valve Implant in Refractory Glaucoma
    Posarelli, Chiara
    Toro, Mario Damiano
    Rejdak, Robert
    Zarnowski, Tomasz
    Pozarowska, Dorota
    Longo, Antonio
    Miccoli, Mario
    Nardi, Marco
    Figus, Michele
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (07) : 1 - 12
  • [3] Scleral avulsion after Ahmed valve M4 removal
    Najla, Hafeezullah
    Sameer, Ahmad
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2019, 33 (04) : 420 - 422
  • [4] Safety and efficacy of ahmed valve on intractable glaucoma in Saudi population
    Osman, Essam A.
    Alkheraiji, Norah F.
    Abouammoh, Mohammad A.
    Mousa, Ahmed
    Al-Obeidan, Saleh
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2020, 27 (01) : 40 - 46
  • [5] Efficacy and safety outcomes of the Paul glaucoma implant compared to the Ahmed glaucoma valve
    Angi Lizbeth Mendoza-Moreira
    Julia V. Stingl
    Anna Maria Voigt
    Jasmin Rezapour
    Achim Fiess
    Felix Mathias Wagner
    Alexander K. Schuster
    Esther M. Hoffmann
    Scientific Reports, 15 (1)
  • [6] One-Year Outcomes of the PAUL Glaucoma Implant Compared With the Ahmed Glaucoma Valve for the Treatment of Silicone Oil Glaucoma
    Karapapak, Murat
    Olgun, Ali
    JOURNAL OF GLAUCOMA, 2024, 33 (05) : 310 - 316
  • [7] A Review of the Ahmed Glaucoma Valve Implant and Comparison with Other Surgical Operations
    Riva, Ivano
    Roberti, Gloria
    Katsanos, Andreas
    Oddone, Francesco
    Quaranta, Luciano
    ADVANCES IN THERAPY, 2017, 34 (04) : 834 - 847
  • [8] Unusual sequelae of staphyloma following Ahmed glaucoma valve explantation and its management
    Kolipaka, Pratinya Gowri
    Krishnamurthy, Rashmi
    Bagga, Bhupesh
    BMJ CASE REPORTS, 2021, 14 (03)
  • [9] Graft survival and glaucoma outcome after simultaneous penetrating keratoplasty and Ahmed glaucoma valve implant
    Al-Torbak, A
    CORNEA, 2003, 22 (03) : 194 - 197
  • [10] Evaluation of success after second Ahmed glaucoma valve implantation
    Nilforushan, Naveed
    Yadgari, Maryam
    Jazayeri, Anis Alsadat
    Karimi, Nasser
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (03) : 206 - 210