Optimized determination of trace jet fuel volatile organic compounds in human blood using in-field liquid-liquid extraction with subsequent laboratory gas chromatographic-mass spectrometric analysis and on-column large-volume injection

被引:23
作者
Liu, SM
Pleil, JD [1 ]
机构
[1] US EPA, Natl Exposure Res Lab, Res Triangle Pk, NC 27711 USA
[2] Mantech Environm Technol Inc, Res Triangle Pk, NC 27709 USA
来源
JOURNAL OF CHROMATOGRAPHY B | 2001年 / 752卷 / 01期
关键词
large-volume injection; JP-8 jet fuel; volatile organic compounds;
D O I
10.1016/S0378-4347(00)00537-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A practical and sensitive method to assess volatile organic compounds (VOCs) from JP-8 jet fuel in human whole blood was developed by modifying previously established liquid-liquid extraction procedures, optimizing extraction times, solvent volume, specific sample processing techniques, and a new on-column large-volume injection method for GC-MS analysis. With the optimized methods, the extraction efficiency was improved by 4.3 to 20.1 times and the detection sensitivity increased up to 660 times over the standard method. Typical detection limits in the parts-per-trillion (ppt) level range were achieved for all monitored JP-8 constituents; this is sufficient for assessing human fuels exposures at trace environmental levels as well as occupational exposure levels. The sample extractions are performed in the field and only solvent extracts need to be shipped to the laboratory. The method is implemented with standard biological laboratory equipment and a modest bench-top GC-MS system. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:159 / 171
页数:13
相关论文
共 37 条
[1]   ENVIRONMENTALLY SIGNIFICANT VOLATILE ORGANIC POLLUTANTS IN HUMAN-BLOOD [J].
ANTOINE, SR ;
DELEON, IR ;
ODELLSMITH, RM .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1986, 36 (03) :364-371
[2]   DETERMINING VOLATILE ORGANIC-COMPOUNDS IN HUMAN BLOOD FROM A LARGE SAMPLE-POPULATION BY USING PURGE AND TRAP GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
ASHLEY, DL ;
BONIN, MA ;
CARDINALI, FL ;
MCCRAW, JM ;
HOLLER, JS ;
NEEDHAM, LL ;
PATTERSON, DG .
ANALYTICAL CHEMISTRY, 1992, 64 (09) :1021-1029
[3]   Measurement of volatile organic compounds in human blood [J].
Ashley, DL ;
Bonin, MA ;
Cardinali, FL ;
McCraw, JM ;
Wooten, JV .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1996, 104 :871-877
[4]   GAS-CHROMATOGRAPHY MASS-SPECTROMETRY COMPUTER-ANALYSIS OF VOLATILE HALOGENATED HYDROCARBONS IN MAN AND HIS ENVIRONMENT - A MULTI-MEDIA ENVIRONMENTAL-STUDY [J].
BARKLEY, J ;
BUNCH, J ;
BURSEY, JT ;
CASTILLO, N ;
COOPER, SD ;
DAVIS, JM ;
ERICKSON, MD ;
HARRIS, BSH ;
KIRKPATRICK, M ;
MICHAEL, LC ;
PARKS, SP ;
PELLIZZARI, ED ;
RAY, M ;
SMITH, D ;
TOMER, KB ;
WAGNER, R ;
ZWEIDINGER, RA .
BIOMEDICAL MASS SPECTROMETRY, 1980, 7 (04) :139-147
[6]   Large-volume injection in capillary gas chromatography using a programmed-temperature vaporizing injector in the on-column or solvent-vent injection mode [J].
Bosboom, JC ;
Janssen, HG ;
Mol, HGJ ;
Cramers, CA .
JOURNAL OF CHROMATOGRAPHY A, 1996, 724 (1-2) :384-391
[7]   BREATH AND BLOOD-LEVELS OF BENZENE, TOLUENE, CUMENE AND STYRENE IN NON-OCCUPATIONAL EXPOSURE [J].
BRUGNONE, F ;
PERBELLINI, L ;
FACCINI, GB ;
PASINI, F ;
MARANELLI, G ;
ROMEO, L ;
GOBBI, M ;
ZEDDE, A .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1989, 61 (05) :303-311
[8]  
CAMPBELL DB, 1976, ASSAY DRUGS OTHER TR, P105
[9]  
Chamberlain J., 1995, ANAL DRUGS BIOL FLUI
[10]  
Cooper JR, 1996, J APPL TOXICOL, V16, P197, DOI 10.1002/(SICI)1099-1263(199605)16:3<197::AID-JAT331>3.0.CO