A microsystem platform interfacing MALDI-TOF MS for high speed automated protein identification

被引:0
作者
Ekström, S [1 ]
Önnerfjord, P [1 ]
Bengtsson, M [1 ]
Miliotis, T [1 ]
Ericsson, D [1 ]
Nilsson, J [1 ]
Marko-Varga, G [1 ]
Laurell, T [1 ]
机构
[1] Univ Lund, Dept Elect Measurements, S-22100 Lund, Sweden
来源
MICRO TOTAL ANALYSIS SYSTEMS 2000, PROCEEDINGS | 2000年
关键词
porous silicon; micro-TAS; microdispensing; MALDI-TOF MS; sample enrichment; proteomics;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A generic micro chemical and fluidic platform interfacing matrix-assisted Laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) that facilitates protein analysis is presented. The microsystem comprises a flow-through piezo dispenser, nanovial MALDI-targets and if needed enzyme (protease) activated porous silicon microreactors (mu -chip IMER) for on-line digestions of proteins. This microsystem can be used to perform enrichment of low abundant, >1 nM, peptides and proteins from 2-DE, mu -LC or to perform protein identification through peptide mass mapping. Applications of the system for automated protein identification, sample enrichment and coupling to mu -LC is demonstrated.
引用
收藏
页码:455 / 458
页数:4
相关论文
共 11 条
  • [1] Drott J, 1999, MIKROCHIM ACTA, V131, P115, DOI 10.1007/s006040050016
  • [2] Pore morphology influence on catalytic turn-over for enzyme activated porous silicon matrices
    Drott, J
    Rosengren, L
    Lindstrom, K
    Laurell, T
    [J]. THIN SOLID FILMS, 1998, 330 (02) : 161 - 166
  • [3] Integrated microanalytical technology enabling rapid and automated protein identification
    Ekström, S
    Önnerfjord, P
    Nilsson, J
    Bengtsson, M
    Laurell, T
    Marko-Varga, G
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (02) : 286 - 293
  • [4] ATTOMOLE DETECTION OF PROTEINS BY MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY WITH THE USE OF PICOLITRE VIALS
    JESPERSEN, S
    NIESSEN, WMA
    TJADEN, UR
    VANDERGREEF, J
    LITBORN, E
    LINDBERG, U
    ROERAADE, J
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (08) : 581 - 584
  • [5] SILICON-WAFER INTEGRATED ENZYME REACTORS
    LAURELL, T
    DROTT, J
    ROSENGREN, L
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) : 289 - 299
  • [6] Design and development of a silicon microfabricated flow-through dispenser for on-line picolitre sample handling
    Laurell, T
    Wallman, L
    Nilsson, J
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1999, 9 (04) : 369 - 376
  • [7] Analysis of single mammalian cell lysates by mass spectrometry
    Li, L
    Golding, RE
    Whittal, RM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (46) : 11662 - 11663
  • [8] MILIOTIS T, IN PRESS J MASS SPEC
  • [9] Weetall H H, 1976, Methods Enzymol, V44, P134
  • [10] Zhang HY, 1996, J MASS SPECTROM, V31, P690, DOI 10.1002/(SICI)1096-9888(199606)31:6<690::AID-JMS349>3.3.CO