Comparison of Time-of-Flight-Magnetic Resonance Angiography From Silent Scan Magnetic Resonance Angiography in Depiction of Arteriovenous Malformation of the Brain

被引:8
|
作者
Tomura, Noriaki [1 ]
Saginoya, Toshiyuki [1 ]
Kokubun, Mika [1 ]
Horiuchi, Kazuomi [1 ]
Watanabe, Zenichiro [1 ]
机构
[1] Southern Tohoku Gen Hosp, Southern Tohoku Res Inst Neurosci, Dept Neuroradiol Radiol & Neurosurg, Koriyama, Fukushima, Japan
关键词
silent scan; magnetic resonance angiography; time of flight; arteriovenous; malformation; COILED INTRACRANIAL ANEURYSMS; SIGNAL-TO-NOISE; MR-ANGIOGRAPHY; FOLLOW-UP; EMBOLIZATION; ACCURACY; PHANTOM; STENT; FLOW;
D O I
10.1097/RCT.0000000000000935
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Silent magnetic resonance angiography (MRA) was compared with time-of-flight (TOF)-MRA in imaging of arteriovenous malformations (AVMs) of the brain. Methods Thirty-five consecutive patients with AVMs of the brain were included. Quantitative analyses were performed by measuring both signal-to-noise ratio and contrast-to-noise ratio of the nidus. Qualitative analysis (scores 1-4) was performed by evaluating depictions of feeding arteries and draining veins independently by 2 reviewers. Results Both signal-to-noise ratio and contrast-to-noise ratio in TOF-MRA were significantly higher than those in silent MRA. For both feeders and drainers, scores were significantly higher in silent MRA than in TOF-MRA for both reviewers. Interrater agreement was higher in silent MRA than in TOF-MRA. Conclusions Silent MRA visualized feeders and drainers in AVMs significantly better than did TOF-MRA. Interrater agreement was also better in silent MRA.
引用
收藏
页码:943 / 947
页数:5
相关论文
共 50 条
  • [31] Failing arteriovenous hemodialysis fistulas - Assessment with magnetic resonance angiography
    Laissy, JP
    Menegazzo, D
    Debray, MP
    Loshkajian, A
    Viron, B
    Mignon, F
    Schouman-Claeys, E
    INVESTIGATIVE RADIOLOGY, 1999, 34 (03) : 218 - 224
  • [32] Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA
    Li, Rui
    Jin, Song
    Wu, Tao
    Zang, Xiao
    Li, Meng
    Li, Jinfeng
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2022, 27 (01)
  • [33] Vasa previa evaluated by noncontrast time-of-flight magnetic resonance angiography
    Lwahashi, Naoyuki
    Ota, Nami
    Shiro, Michihisa
    Yagi, Shigetaka
    Minami, Sawako
    Ina, Kazuhiko
    TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2016, 55 (04): : 585 - 587
  • [34] Usefulness of silent magnetic resonance angiography (MRA) for the diagnosis of atherosclerosis of the internal carotid artery siphon in comparison with time-of-flight MRA
    Rui Li
    Song Jin
    Tao Wu
    Xiao Zang
    Meng Li
    Jinfeng Li
    European Journal of Medical Research, 27
  • [35] MAGNETIC-RESONANCE ANGIOGRAPHY TECHNIQUES
    PRICE, RR
    CREASY, JL
    LORENZ, CH
    PARTAIN, CL
    INVESTIGATIVE RADIOLOGY, 1992, 27 : S27 - S32
  • [36] Magnetic resonance pulmonary angiography
    Wielopolski, PA
    CORONARY ARTERY DISEASE, 1999, 10 (03) : 157 - 175
  • [37] Magnetic resonance angiography in trauma
    James, CA
    CLINICAL NEUROSCIENCE, 1997, 4 (03) : 137 - 145
  • [38] MAGNETIC-RESONANCE ANGIOGRAPHY
    ATKINSON, D
    TERESI, L
    MAGNETIC RESONANCE QUARTERLY, 1994, 10 (03) : 149 - 172
  • [39] Cardiothoracic Magnetic Resonance Angiography
    Kocaoglu, Murat
    Pednekar, Amol
    Fleck, Robert J.
    Dillman, Jonathan R.
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2024, 53 (01) : 154 - 165
  • [40] Ghost Magnetic Resonance Angiography
    Koktzoglou, Ioannis
    Edelman, Robert R.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1515 - 1519